DTC P0327 Knock Sensor 1 Circuit Low Input (Bank 1 or Single Sensor) |
DTC P0328 Knock Sensor 1 Circuit High Input (Bank 1 or Single Sensor) |
DTC P0332 Knock Sensor 2 Circuit Low Input (Bank 2) |
DTC P0333 Knock Sensor 2 Circuit High Input (Bank 2) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0327 P0332 | Output voltage of the knock sensor 1 or 2 is 0.5 V or less (1 trip detection logic) |
|
| P0328 P0333 | Output voltage of the knock sensor 1 or 2 is 4.5 V or more (1 trip detection logic) |
|

| Item | Details |
| Terminal | KNK1 - EKNK or KNK2 - EKN2 |
| Equipment Settings | 0.01 to 10 V/Division, 0.01 to 10 msec./Division |
| Condition | After warming up the engine, keep the engine speed at 4000 rpm. |
| Related DTCs | P0327: Knock sensor (Bank 1) range check (Low voltage) P0328: Knock sensor (Bank 1) range check (High voltage) P0332: Knock sensor (Bank 2) range check (Low voltage) P0333: Knock sensor (Bank 2) range check (High voltage) |
| Required sensors/components (Main) | Knock sensor (Bank 1 and 2) |
| Required sensor/components (Related) | Mass air flow meter, Crankshaft position sensor, Camshaft position sensor Engine coolant temperature sensor |
| Frequency of operation | Continuous |
| Duration | 1 second |
| MIL operation | Immediate |
| Sequence operation | None |
| Monitor runs whenever following DTCs are not present | None |
| Battery voltage | 10.5 V or more |
| Time after engine start | 5 seconds or more |
| Power switch | ON |
| Knock sensor voltage | Less than 0.5 V |
| Knock sensor voltage | More than 4.5 V |

| 1.READ OUTPUT DTC (CHECK KNOCK SENSOR CIRCUIT) |
![]() |
Disconnect the Bd1 connector.
Using lead wires, connect the Bd1 terminals as follows.
| Male Connector - Female Connector |
| Terminal 2 - Terminal 4 |
| Terminal 1 - Terminal 3 |
| Terminal 4 - Terminal 2 |
| Terminal 3 - Terminal 1 |
Warm up the engine.
Run the engine at 2500 rpm for 10 seconds or more.
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Select the items: Powertrain / Engine and ECT / Trouble Codes.
Read the DTCs.
| Display | Proceed to |
| DTCs same as when vehicle brought in P0327, P0328 → P0327, P0328 or P0332, P0333 → P0332, P0333 | A |
| DTCs different from when vehicle brought in P0327, P0328 → P0332, P0333 or P0332, P0333 → P0327, P0328 | B |
Reconnect the Bd1 connector.
|
| ||||
| A | |
| 2.CHECK HARNESS AND CONNECTOR (Bd1 CONNECTOR - HYBRID VEHICLE CONTROL ECU) |
![]() |
Disconnect the Bd1 connector.
![]() |
Disconnect the hybrid vehicle control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Bd1 female connector 2 - B2-29 (KNK1) | Always | Below 1 Ω |
| Bd1 female connector 1 - B2-28 (EKNK) | Always | |
| Bd1 female connector 4 - B2-21 (KNK2) | Always | |
| Bd1 female connector 3 - B2-20 (EKN2) | Always |
| Tester Connection | Condition | Specified Condition |
| Bd1 female connector 2 or B2-29 (KNK1) - Body ground | Always | 10 kΩ or higher |
| Bd1 female connector 1 or B2-28 (EKNK) - Body ground | Always | |
| Bd1 female connector 4 or B2-21 (KNK2) - Body ground | Always | |
| Bd1 female connector 3 or B2-20 (EKN2) - Body ground | Always |
Reconnect the Bd1 connector.
Reconnect the hybrid vehicle control ECU connector.
|
| ||||
| OK | |
| 3.CHECK HYBRID VEHICLE CONTROL ECU |
![]() |
Disconnect the hybrid vehicle control ECU connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B2-29 (KNK1) - B2-28 (EKNK) | Power switch on (IG) | 4.5 to 5.5 V |
| B2-21 (KNK2) - B2-20 (EKN2) | Power switch on (IG) |
Reconnect the hybrid vehicle control ECU connector.
|
| ||||
| OK | ||
| ||
| 4.CHECK KNOCK CONTROL SENSOR (SENSOR RESISTANCE) |
![]() |
Disconnect the Bd1 connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Bd1 male connector 2 - 1 | Always | 120 to 280 kΩ |
| Bd1 male connector 4 - 3 | Always |
Reconnect the Bd1 connector.
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (Bd1 CONNECTOR - KNOCK CONTROL SENSOR) |
![]() |
Disconnect the Bd1 connector.
Disconnect the d1 or d2 knock sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Bd1 male connector 2 - d1-2 | Always | Below 1 Ω |
| Bd1 male connector 1 - d1-1 | Always | |
| Bd1 male connector 4 - d2-2 | Always | |
| Bd1 male connector 3 - d2-1 | Always |
| Tester Connection | Condition | Specified Condition |
| Bd1 male connector 2 - d1-2 or Body ground | Always | 10 kΩ or higher |
| Bd1 male connector 1 - d1-1 or Body ground | Always | |
| Bd1 male connector 4 - d2-2 or Body ground | Always | |
| Bd1 male connector 3 or d2-1 - Body ground | Always |
Reconnect the Bd1 connector.
Reconnect the knock sensor connector.
|
| ||||
| OK | ||
| ||