DTC P1420 Evaporative Emission Canister Small Leak |
DTC P1421 Evaporative Emission Canister Gross Leak |
| DTC No. | Monitoring Item | DTC Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P1420 | EVAP small leak | Vacuum pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard is measured at the start and at the end of leak check. If stabilized pressure is higher than second 0.02 inch leak pressure standard, ECM (included in the hybrid vehicle control ECU) determines that EVAP system has a small leak. |
| While power switch off | 2-trip |
| P1421 | EVAP gross leak | Vacuum pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure is measured. 0.02 inch leak pressure standard is measured at the start and at the end of leak check. If stabilized pressure is higher than [second 0.02 inch leak pressure standard x 0.2], ECM (included in the hybrid vehicle control ECU) determines that purge VSV stuck open | Same as above | While power switch off | 2-trip |

| Required Sensors/Components | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 15 minutes (varies with the amount of fuel in tank) |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs are not present | None |
| EVAP key-off monitor runs when all of the following conditions are met: | - |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Below 2.5 mph (4 km/h) |
| Power switch | OFF |
| Engine condition | Not running |
| Pressure sensor (built in canister pump module) malfunction (P0450, P0451, P0452 and/or P0453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before power switch OFF | Conditions 1 and 2 |
| 1. Duration that vehicle is being driven | 5 minutes |
| 2. Purge flow | Executed |
| Engine coolant temperature | 4.4 to 35°C (40 to 95°F) |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| Time after engine stopped | 5 hours |
| First time | 7 hours |
| Second time | 9 hours and 30 minutes |
| Next sequence is run if the following condition is met: | - |
| Atmospheric pressure change for 10 sec. | Less than 0.3 kPa (2.25 mmHg) for 1 second |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2 and 3 |
| 1. EVAP pressure 1.9 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated within 55 seconds |
| Next sequence is run if the following condition is met: | - |
| EVAP change for 10 seconds after vent valve ON (Closed) | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if both of the following conditions are met: | Conditions 1 and 2 |
| 1. Vacuum introduction time | 15 minutes or less |
| 2. EVAP pressure | Saturated |
| Next sequence is run if the following condition is met: | - |
| EVAP pressure change for 10 seconds after Purge VSV ON (Open). | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2, 3 and 4 |
| 1. EVAP pressure 1.9 seconds after reference pressure measurement began | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated within 55 seconds |
| 4. Reference pressure difference between the first and second | 0.7 kPa (5.25 mmHg) or less |
| Next sequence is run if the following condition is met: | - |
| Canister pressure when vacuum introduction was complete | Less than second reference pressure |
| Sequence 14 is run if both of the following conditions are met: | Conditions 1 and 2 |
| 1. FTP when EVAP monitor started | -2 kPa (-15 mmHg) or less, or 3 kPa (22.5 mmHg) or more |
| 2. FTP change while FVCV and vent valve are open | 0.5 kPa (3.75 mmHg) or more |
| Next sequence is run if both of the following conditions are met: | Conditions 1 and 2 |
| 1. FTP when EVAP monitor started | -2 to 3 kPa (-15 to 22.5 mmHg) |
| 2. Vacuum introduction time | 15 minutes or less |
| Next sequence is run if the following condition is met: | - |
| FTP change when vacuum introduction for fuel tank | 0.5 kPa (3.75 mmHg) |
| Next sequence is run if the following condition is met: | - |
| FTP change when FVCV closed | 0.35 kPa (2.6 mmHg) or less |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2, 3, and 4 |
| 1. FTP when 1.9 seconds after reference pressure measurement began | -1 kPa (-7.5 mmHg) or more |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated |
| 4. Reference pressure difference between second and third measurement | Less than 0.7 kPa (5.25 mmHg) |
| Sequence is run if the following condition is met: | - |
| FTP when vacuum introduction for fuel tank was complete | Less than third reference pressure |
| Next sequence is run if the following condition is met: | - |
| FTP change while FVCV and vent valve are open | Less than 0.3 kPa (2.25 mmHg) |
| Monitor is complete if the following condition is met: | - |
| Atmospheric pressure difference between sequences 1 and 8 | 0.35 kPa (2.6 mmHg) or less |
| EVAP pressure when vacuum introduction complete | Higher than reference pressure x 0.2 |
| EVAP pressure when vacuum introduction is complete | Between conditions 1 and 2 |
| Condition 1 | Higher than second reference pressure |
| Condition 2 | Lower than reference pressure x 0.2 |
| Atmospheric pressure (absolute pressure) | 70 kPa (525 mmHg) or more, and less than 110 kPa (825 mmHg) |