Home › ENGINE › 3MZ-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P2450    Fuel Vapor-containment Valve Stuck Open

DTC    P2451    Fuel Vapor-containment Valve Stuck Close

for Preparation Click here


DTC SUMMARY


DTC No.
Monitoring Item
DTC Detection Condition
Trouble Area
Detection Timing
Detection Logic
P2450
Fuel vapor-containment valve stuck open
One of the following conditions is met when FTP is between -2 kPa (-15 mmHg) and 3 kPa (22.5 mmHg).
  1. FTP change when vacuum introduction for fuel tank is less than 0.5 kPa (3.75 mmHg)
  2. EVAP pressure change when FVCV is open is less than 0.9 kPa (6.75 mmHg)
  1. Fuel vapor-containment valve
  2. Connector / wire harness (Fuel vapor-containment valve - Hybrid vehicle control ECU)
  3. Hybrid vehicle control ECU
Power switch off
2 trip
P2451
Fuel vapor-containment valve stuck closed
One of the following conditions is met when FTP is between -2 kPa (-15 mmHg) and 3 kPa (22.5 mmHg).
  1. FTP change when vacuum introduction for canister is less than 0.5 kPa (3.75 mmHg)
  2. EVAP pressure when vacuum introduction for canister was complete is higher than (third reference pressure x 0.2)
  1. Fuel vapor-containment valve
  2. Connector / wire harness (Fuel vapor-containment valve - Hybrid vehicle control ECU)
  3. Hybrid vehicle control ECU
Power switch off
2 trip

DESCRIPTION

Refer to EVAP System .

MONITOR DESCRIPTION

  1. P2450: Fuel vapor-containment valve (FVCV) stuck open
    During sequence C, the vacuum pump creates vacuum in the EVAP system. If the pressure in the fuel tank drops, the ECM (included in the hybrid vehicle control ECU) determines that the tank close valve is stuck open. The ECM then illuminates the MIL and sets the DTC. (This DTC is set according to 2 trip detection logic.)

  2. P2451: Fuel vapor-containment valve (FVCV) stuck closed (vent)
    During sequence G, the tank close valve opens to allow vacuum pressure generated by the vacuum pump into the fuel tank. If the pressure in the fuel tank does not drop, the ECM determines that the tank close valve is stuck closed. The ECM then illuminates the MIL and sets the DTC. (This DTC is set according to 2 trip detection logic.)
    During sequence I, the tank close valve opens to allow atmospheric pressure into the fuel tank. If there is no change in fuel tank pressure, the ECM determines that the tank close valve is stuck closed. The ECM then illuminates the MIL and sets the DTC. (This DTC is set according to 2 trip detection logic.)


    A109164E04


MONITOR STRATEGY


Required Sensors/Components
Fuel vapor-containment valve and canister pump module
Frequency of Operation
Once per driving cycle: P0451 (sensor constant voltage)
Continuous: P0451 (sensor fluctuation voltage), P0452 and P0453
Duration
Within 15 seconds
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs are not present
None
EVAP key-off monitor runs when all of the following conditions are met:
-
Atmospheric pressure
70 to 110 kPa (525 to 825 mmHg)
Battery voltage
10.5 V or more
Vehicle speed
Below 2.5 mph (4 km/h)
Power switch
OFF
FTP sensor malfunction (P0450, P0451, P0452 and P0453)
Not detected
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of the following conditions are met before power switch off:
Conditions 1 and 2
1. Duration that vehicle is being driven
5 minutes
2. EVAP purge operation
Performed
Engine coolant temperature
4.4 to 35°C (40 to 95°F)
Intake air temperature
4.4 to 35°C (40 to 95°F)
Time after engine stop
5 hours

Example of restart time 
First time
7 hours
Second time
9 hours and 30 minutes
  1. Key-off monitor sequence 1 to 15

    1. Atmospheric pressure measurement 
    Next sequence is run if the following condition is met:
    -
    Atmospheric pressure change for 10 seconds
    Less than 0.3 kPa (2.25 mmHg) for 1 second

    2. First reference pressure measurement 
    Next sequence is run if all of the following conditions are met:
    Conditions 1, 2 and 3
    1. EVAP pressure 1.9 seconds after reference pressure measurement
    -1 kPa (-7.5 mmHg) or less
    2. Reference pressure
    -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg)
    3. Reference pressure
    Saturated within 55 seconds

    3. Vent valve stuck closed check 
    Next sequence is run if the following condition is met:
    -
    EVAP pressure change for 10 seconds after vent valve ON (Closed)
    0.3 kPa (2.25 mmHg) or more

    4. Vacuum introduction for canister 
    Next sequence is run if both of the following conditions are met:
    Conditions 1 and 2
    1. Vacuum introduction time
    15 minutes or less
    2. FTP
    Saturated

    5. Purge VSV stuck closed check 
    Next sequence is run if the following condition is met:
    -
    EVAP pressure change for 10 seconds after Purge VSV ON (Open)
    0.3 kPa (2.25 mmHg) or more

    6. Second reference pressure measurement 
    Next sequence is run if all of the following conditions are met:
    Conditions 1, 2, 3 and 4
    1. EVAP pressure when 1.9 seconds after reference pressure measurement
    -1kPa (-7.5 mmHg) or less
    2. Reference pressure
    -4.85 to -1.057 kPa (-36.4 to -7.92 mmHg)
    3. Reference pressure
    Saturated within 55 seconds
    4. Reference pressure difference between the first and second
    0.7 kPa (5.25 mmHg) or less

    7. Canister leak 
    Next sequence is run if the following condition is met:
    -
    Canister leaks when vacuum introduction was complete
    Less than second reference pressure

    8. Fuel vapor-containment valve (FVCV stuck closed check) 
    Sequence 14 is run if both of the following conditions are met:
    Conditions 1 and 2
    1. FTP when EVAP monitor started
    -2 kPa (-15 mmHg) or less, or 3 kPa (22.5 mmHg) or more
    2. FTP change while FVCV and vent valve are open
    3.75 mmHg (0.5 kPa) or more

    9. Vacuum introduction for fuel tank 
    Next sequence is run if both of the following conditions are met:
    Conditions 1 and 2
    1. FTP when EVAP monitor started
    -2 to 3 kPa (-15 to 22.5 mmHg)
    2. Vacuum introduction time
    15 minutes or less

    10. FVCV stuck closed check 
    Next sequence is run if the following condition is met:
    -
    FTP change when vacuum introduction for fuel tank
    0.5 kPa (5.25 mmHg)

    11. FTP sensor stuck check 
    Next sequence is run if the following condition is met:
    -
    FTP change when FVCV closed
    0.35 kPa (2.6 mmHg) or less

    12 Third reference pressure measurement 
    Next sequence is run if all of the following conditions are met:
    Conditions 1, 2, 3, and 4
    1. FTP 1.9 seconds after reference pressure measurement began
    -1 kPa (-7.5 mmHg) or more
    2. Reference pressure
    -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg)
    3. Reference pressure
    Saturated
    4. Reference pressure difference between the second and third
    Less than 0.7 kPa (5.25 mmHg)

    13. Fuel tank leak check 
    Sequence is run if the following condition is met:
    -
    FTP when vacuum introduction for fuel tank was complete
    Less than third reference pressure

    14. FTP sensor stuck check 
    Next sequence is run if the following condition is met:
    -
    FTP change while FVCV and vent valve are open
    Less than 0.3 kPa (2.25 mmHg)

    15. Atmospheric pressure measurement 
    Monitor is complete if the following condition is met:
    -
    Atmospheric pressure difference between sequences 1 and 8
    0.35 kPa (2.6 mmHg) or less

TYPICAL MALFUNCTION THRESHOLDS

"Saturated" indicates that the EVAP pressure change is less than 0.286 kPa (2.14 mmHg) in 60 seconds.

1. P2450: Fuel vapor-containment valve stuck open 
One of the following conditions is met when FTP is between -2 kPa (-15 mmHg) and 3 kPa (22.5 mmHg)
1 or 2
1. Both of the following conditions are met
(a) or (b)
(a) FTP
-2 to 3 kPa (-15 to 22.5 mmHg)
(b) FTP change when vacuum introduction for fuel tank
More than 0.5 kPa (3.75 mmHg)
1. Both of the following conditions are met
(a) or (b)
(a) FTP
-2 to 3 kPa (-15 to 22.5 mmHg)
(b) Arrival pressure when vacuum introduced for fuel tank
Higher than reference pressure x 0.2

2. P2451: Fuel vapor-containment valve stuck close 
One of the following conditions is met when FTP is between -2 kPa (-15 mmHg) and 3 kPa (22.5 mmHg)
1 or 2
1. FTP change when vacuum introduction for fuel tank
Less than 0.5 kPa (3.75 mmHg)
2. Pressure at vacuum pump change when fuel vapor-containment valve open operation
Less than 0.9 kPa (6.75 mmHg)

MONITOR RESULT

Refer to EVAP System .

INSPECTION PROCEDURE

Refer to EVAP System .