DTC B1462/62 Room Humidity Sensor Circuit |
| DTC No. | DTC Detecting Condition | Trouble Area |
| B1462/62 | Open or short in room humidity sensor circuit |
|

| 1.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY |
![]() |
Remove the air conditioning amplifier assembly with the connectors still connected.
Measure the voltage according to the value(s) in the table below.
| Tester connection (Symbols) | Condition | Specified condition |
| D37-28 (RH) - D37-31 (S5-4) | Power switch on (IG) at 25°C (77°F) | 1.8 to 2.2 V |
| D37-28 (RH) - D37-31 (S5-4) | Power switch on (IG) at 40°C (104°F) | 1.2 to 1.6 V |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT ROOM TEMPERATURE SENSOR |
![]() |
Remove the room temperature sensor with its connector still connected.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified Condition |
| D26-3 (RH) - D26-4 (S5) | Humidity 10% at 25°C (77°F) | 0.7 to 1.08 V |
| D26-3 (RH) - D26-4 (S5) | Humidity 20% at 25°C (77°F) | 0.72 to 1.57 V |
| D26-3 (RH) - D26-4 (S5) | Humidity 30% at 25°C (77°F) | 1.13 to 1.95 V |
| D26-3 (RH) - D26-4 (S5) | Humidity 40% at 25°C (77°F) | 1.61 to 2.24 V |
| D26-3 (RH) - D26-4 (S5) | Humidity 650% at 25°C (77°F) | 1.99 to 2.46 V |
| D26-3 (RH) - D26-4 (S5) | Humidity 60% at 25°C (77°F) | 2.26 to 2.66 V |
| D26-3 (RH) - D26-4 (S5) | Humidity 70% at 25°C (77°F) | 2.48 to 2.85 V |
| D26-3 (RH) - D26-4 (S5) | Humidity 80% at 25°C (77°F) | 2.68 to 3.04 V |
| D26-3 (RH) - D26-4 (S5) | Humidity 90% at 25°C (77°F) | 2.87 to 3.05 V |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
![]() |
Disconnect the connector from the air conditioning amplifier assembly.
Measure the resistance according to the value(s) in the table below.
| Tester connection (Symbols) | Condition | Specified condition |
| D37-28 (RH) - D26-3 (RH) | Always | Below 1 Ω |
| D37-31 (S5-4) - D26-4 (S5) | Always | Below 1 Ω |
| D37-28 (RH) - Body ground | Always | 10 kΩ or higher |
| D37-31 (S5-4) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||