DTC    B1462/62    Room Humidity Sensor Circuit

for Preparation Click here


DESCRIPTION

The room humidity sensor detects cabin humidity. The voltage of the room humidity sensor changes in accordance with cabin humidity. The air conditioning amplifier assembly reads changes in the room humidity sensor.
The room humidity sensor is integrated with the room temperature sensor.

DTC No.
DTC Detecting Condition
Trouble Area
B1462/62
Open or short in room humidity sensor circuit
  1. Room temperature sensor (for front)
  2. Harness or connector between room temperature sensor (for front) and air conditioning amplifier assembly
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E158847E01


INSPECTION PROCEDURE

1.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY


    E158953E01
  1. Remove the air conditioning amplifier assembly with the connectors still connected.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester connection
    (Symbols)
    Condition
    Specified condition
    D37-28 (RH) - D37-31 (S5-4)
    Power switch on (IG)
    at 25°C (77°F)
    1.8 to 2.2 V
    D37-28 (RH) - D37-31 (S5-4)
    Power switch on (IG)
    at 40°C (104°F)
    1.2 to 1.6 V

    HINT:
    As the temperature increases, the voltage decreases.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
A


2.INSPECT ROOM TEMPERATURE SENSOR


    E108929E13
  1. Remove the room temperature sensor with its connector still connected.

  1. Turn the power switch on (IG).



    E109268E02
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester connection
    Condition
    Specified Condition
    D26-3 (RH) - D26-4 (S5)
    Humidity 10%
    at 25°C (77°F)
    0.7 to 1.08 V
    D26-3 (RH) - D26-4 (S5)
    Humidity 20%
    at 25°C (77°F)
    0.72 to 1.57 V
    D26-3 (RH) - D26-4 (S5)
    Humidity 30%
    at 25°C (77°F)
    1.13 to 1.95 V
    D26-3 (RH) - D26-4 (S5)
    Humidity 40%
    at 25°C (77°F)
    1.61 to 2.24 V
    D26-3 (RH) - D26-4 (S5)
    Humidity 650%
    at 25°C (77°F)
    1.99 to 2.46 V
    D26-3 (RH) - D26-4 (S5)
    Humidity 60%
    at 25°C (77°F)
    2.26 to 2.66 V
    D26-3 (RH) - D26-4 (S5)
    Humidity 70%
    at 25°C (77°F)
    2.48 to 2.85 V
    D26-3 (RH) - D26-4 (S5)
    Humidity 80%
    at 25°C (77°F)
    2.68 to 3.04 V
    D26-3 (RH) - D26-4 (S5)
    Humidity 90%
    at 25°C (77°F)
    2.87 to 3.05 V

    NOTICE:
    1. Touching the sensor even slightly may change the output voltage. Be sure to hold the connector of the sensor.
    2. The output voltages shown above are at 25°C (77°F).



NG
REPLACE ROOM TEMPERATURE SENSOR (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    E158846E02
  1. Disconnect the connector from the air conditioning amplifier assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester connection
    (Symbols)
    Condition
    Specified condition
    D37-28 (RH) - D26-3 (RH)
    Always
    Below 1 Ω
    D37-31 (S5-4) - D26-4 (S5)
    Always
    Below 1 Ω
    D37-28 (RH) - Body ground
    Always
    10 kΩ or higher
    D37-31 (S5-4) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)