Home › BODY ELECTRICAL › OTHER SYSTEM › CLOCK SYSTEM

CLOCK SYSTEM > TERMINALS OF ECU

for Preparation Click here



CLOCK ASSEMBLY

HINT:
Measure the voltage with the connector still connected.


E146933E01


Terminal No. (Symbols)
Wiring Color
Terminal Description
Condition
Specified Condition
E11-1 (IG) - Body ground
P - Body ground
Power switch signal
Power switch off
Below 1 V
Power switch on (READY)
11 to 14 V
E11-5 (GND) - Body ground
W-B - Body ground
Ground
Always
Below 1 V
E11-6 (+B) - Body ground
Y - Body ground
Battery
Always
11 to 14 V
E11-9 (CLK) - Body ground
R - Body ground
Multi-information display signal
Power switch on (READY)
Pulse generation
E11-10 (DATA) - Body ground
Y - Body ground
Multi-information display signal
Power switch on (READY)
Pulse generation
E11-11 (SYNC) - Body ground
L - Body ground
Multi-information display signal
Power switch on (READY)
Pulse generation
E11-16 (SGND) - Body ground
BR - Body ground
Ground (Signal Ground)
Always
Always