Home › ENGINE › 3MZ-FE ENGINE CONTROL SYSTEM › CAMSHAFT OIL CONTROL VALVE

CAMSHAFT OIL CONTROL VALVE > INSPECTION

for Preparation Click here



1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
  1. Resistance inspection

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      20°C (68°F)
      6.9 to 7.9 Ω

      If necessary, replace the camshaft oil control valve assembly.



    A164451E01
  1. Movement inspection

    1. Connect the positive (+) lead from the battery to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.

      NOTICE:
      Confirm that the valve moves freely and does not stick in any position.

      If necessary, replace the camshaft oil control valve assembly.

      HINT:
      Accumulation of foreign objects causes subtle pressure leaks. The subtle pressure leaks will cause the cam to advance, and this will cause a DTC to be set.