Home › ENGINE › 3MZ-FE ENGINE CONTROL SYSTEM › CRANKSHAFT POSITION SENSOR

CRANKSHAFT POSITION SENSOR > INSPECTION

for Preparation Click here



1. INSPECT CRANKSHAFT POSITION SENSOR


    A108285
  1. Using an ohmmeter, measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Cold
    1630 to 2740 Ω
    Hot
    2065 to 3225 Ω

    HINT:
    1. "Cold" and "Hot" refer to the temperature of the coils themselves.
    2. "Cold" is from -10°C (14°F) to 50°C (122°F) and "Hot" is from 50°C (122°F) to 100°C (212°F).

    If the resistance is not as specified, replace the sensor.