PURGE VALVE > INSPECTION |
| 1. INSPECT DUTY VACUUM SWITCHING VALVE |
Check the VSV for an open circuit.
![]() |
Using an ohmmeter, measure the resistance between the terminals.
| Tester Connection | Specified Condition |
| 1 - 2 | 26 to 30 Ω at 20°C (68°F) |
Check operation of the VSV.
![]() |
Check that air does not flow from the port as shown in the illustration.
If the result is not as specified, replace the VSV.
![]() |
Apply battery voltage across the terminals.
Check that air flows from the port as shown in the illustration.
If the result is not as specified, replace the VSV.