HEATED OXYGEN SENSOR > INSPECTION |
| 1. INSPECT OXYGEN SENSOR |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (HT1B) - 1 (+B) | 20°C (68°F) | 11 to 16 Ω |
| 2 (HT1B) - 3 (E2) | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| 1 (HT2B) - 2 (+B) | 20°C (68°F) | 11 to 16 Ω |
| 1 (HT2B) - 4 (E2) | Always | 10 kΩ or higher |