Home › ENGINE › 3MZ-FE ENGINE CONTROL SYSTEM › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT OXYGEN SENSOR


    A141063E08
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Bank 1 
    Tester Connection
    Condition
    Specified Condition
    2 (HT1B) - 1 (+B)
    20°C (68°F)
    11 to 16 Ω
    2 (HT1B) - 3 (E2)
    Always
    10 kΩ or higher
    Bank 2 
    Tester Connection
    Condition
    Specified Condition
    1 (HT2B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT2B) - 4 (E2)
    Always
    10 kΩ or higher