Home › BODY ELECTRICAL › PARK ASSIST / MONITORING › REAR VIEW MONITOR SYSTEM (w/o Navigation System)

REAR VIEW MONITOR SYSTEM (w/o Navigation System) > TERMINALS OF ECU

for Preparation Click here



TELEVISION CAMERA ASSEMBLY


  1. Disconnect the S1 camera connector.


    E150739E03

  2. Measure the voltage of each terminal of the wire harness side connector.

    Terminal No. (Symbols)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    S1-3 (CGND) - Body ground
    W - Body ground
    Ground
    Always
    Below 1 V
    S1-4 (CB+) - S1-3 (CGND)
    B - W
    Power source
    Power switch on (IG)
    Shift lever R position
    5.5 to 7 V
    If the result is not as specified, there may be a malfunction on the wire harness side.

  3. Reconnect the S1 camera connector.

  4. Measure the voltage and frequency of each terminal of the connector.

    Terminal No. (Symbols)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    S1-1 (CV-) - S1-2 (CV+)
    BR - R
    Display signal
    Power switch on (IG)
    Shift lever R position
    Pulse generation
    (See waveform 1)
    If the result is not as specified, the camera may have a malfunction.



  5. E119731E01
  6. Reference:
    Oscilloscope waveform

    1. Waveform 1
      Item
      Content
      Measure terminal
      S1-1 (CV-) - S1-2 (CV+)
      Measure set
      0.2 V/DIV., 0.2 μS/DIV.
      Condition
      Power switch: on (IG), Shift lever: R position


CLOCK ASSEMBLY (Multi-Information Display)

E146933E02


Terminal No. (Symbols)
Wiring Color
Terminal Description
Condition
Specified Condition
E11-1 (IG) - E11-5 (GND)
P - W-B
Power switch signal
Power switch off
Below 1 V
Power switch on (IG)
11 to 14 V
E11-2 (REV) - E11-5 (GND)
R - W-B
Reverse signal
Power switch on (IG)
Shift lever except R position
Below 1 V
Power switch on (IG)
Shift lever R position
11 to 14 V
E11-4 (CGND) - E11-5 (GND)
W - W-B
Television camera ground
Always
Below 1 V
E11-5 (GND) - Body ground
W-B - Body ground
Ground
Always
Below 1 V
E11-6 (+B) - E11-5 (GND)
Y - W-B
Battery
Always
11 to 14 V
E11-12 (CA+) - E11-5 (GND)
B - W-B
Power source to television camera
Power switch on (IG)
Shift lever R position
5.5 to 7 V
E11-14 (V+) - E11-5 (GND)
R - W-B
Television camera display signal (Input)
Power switch on (IG)
Shift lever R position
Pulse generation
(See waveform 1)
E11-15 (V-) - E11-5 (GND)
Shielded - W-B
Television camera ground (Shielded)
Always
Below 1 V
E11-16 (SGND) - Body ground
BR - Body ground
Signal ground
Always
Below 1 V


    E119731E06
  1. Reference:
    Oscilloscope waveform

    1. Waveform 1
      Item
      Content
      Measure terminal
      E11-14 (V+) - E11-15 (V-)
      Measure set
      0.2 V/DIV., 0.2 μS/DIV.
      Condition
      Power switch: on (IG), Shift lever: R position