Home › BODY › ENGINE HOOD / DOOR › FUEL LID OPENER SYSTEM

FUEL LID OPENER SYSTEM > SYSTEM DESCRIPTION

for Preparation Click here



FUEL LID OPENER COMPONENTS

Fuel Lid Opener Switch
Detects fuel lid opener switch operation and sends fuel lid open request signal to the hybrid vehicle control ECU.
Fuel Lid Courtesy Switch
Sends the fuel lid open/close status signal to the hybrid vehicle control ECU.
Fuel Lid Opener Motor Assembly
Actuates to open the fuel lid according to signal from the hybrid vehicle control ECU.
Hybrid Vehicle Control ECU
When the hybrid vehicle control ECU receives a signal from the fuel lid opener switch, it actuates the fuel lid opener motor.
  1. Inputs a signal from the fuel tank pressure sensor.
  2. When the fuel tank internal pressure exceeds 1.76 kPa, the hybrid vehicle control ECU operates the fuel vapor containment valve.
  3. Detects status of the fuel lid courtesy switch.
Multi-information Display
The operating state of fuel lid opener system is displayed on the multi-information display.

FUEL LID OPENER SYSTEM FUNCTION


  1. When the fuel lid opener switch is pressed, a fuel lid open request signal is sent to the hybrid control ECU, and the fuel lid opener motor actuates to open the fuel lid.

    HINT:
    When the fuel tank internal pressure exceeds 1.76 kPa, the fuel vapor containment valve is used to adjust the pressure. If the fuel tank internal pressure is 4.0 kPa or more, "PLEASE WAIT NOW OPENING" is displayed on the multi-information display. If the fuel tank internal pressure is greater than 1.76 kPa, the multi-information display will remain off until the fuel tank internal pressure drops to 1.76 kPa, at which point the multi-information display will show "REFUEL READY".

    NOTICE:
    1. If the fuel tank pressure sensor or fuel vapor containment valve is malfunctioning, the fuel lid does not open.
    2. If the fuel lid courtesy switch is malfunctioning, "CLOSE FUEL LID" is displayed on the multi-information display even if the fuel lid is closed.


    B150826E05


    B178876E02




    1. Normal operation (Fuel tank pressure 4 kPa or more):


      B150831E03



    2. Normal operation (Fuel tank pressure less than 4 kPa)


      B150829E03


MULTI-INFORMATION DISPLAY OPERATION


  1. Multi-information display operation:


    B178865E02


    Display
    Details
    Condition
    Condition to switch to next display
    Next display
    PLEASE WAIT NOW OPENING
    1. Wait time until the fuel tank pressure drops to the specified value
    2. Wait time until the fuel lid is opened
    1. Fuel lid opener switch ON
    2. Fuel vapor containment valve open
    3. Fuel tank pressure 4 kPa or more (Initial value)
    Fuel tank pressure less than 1.76 kPa
    REFUEL READY
    REFUEL READY
    Ready for refueling
    Until any of the conditions listed on the right are met.
    When 5 seconds or more elapse after fuel lid CLOSE (Fuel lid courtesy switch ON)
    OFF
    1. The fuel vapor containment valve remains ON for 30 min.
    2. The vehicle is driven for 1 km or more at 50 km/h or more
    CLOSE FUEL LID
    CLOSE FUEL LID
    Fuel lid open
    Fuel lid open:
    1. While the power switch is on (IG)
    2. For 5 min. after the power switch is turned off
    Fuel lid CLOSE (Door control switch ON)
    OFF