Home › BODY ELECTRICAL › LIGHTING › VANITY LIGHT

VANITY LIGHT > INSPECTION

for Preparation Click here



1. INSPECT VANITY LIGHT ASSEMBLY


    E133263E07
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    LH Side:
    Tester Connection
    Condition
    Specified Condition
    Q8-1 - Q8-2
    Visor raise
    Below 1 V
    Visor lower and mirror cover open
    11 to 14 V
    Visor lower and mirror cover close
    Below 1 V
    RH Side:
    Tester Connection
    Condition
    Specified Condition
    Q6-1 - Q6-2
    Visor raise
    Below 1 V
    Visor lower and mirror cover open
    11 to 14 V
    Visor lower and mirror cover close
    Below 1 V

    If the result is not as specified, there is a malfunction on the wire harness side.
    If the result is as specified, but the vanity light does not come on, replace the bulb.