Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1411/11    Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The room temperature sensor is installed in the instrument panel to detect the cabin temperature and control the heater and air conditioning AUTO mode. The resistance of the room temperature sensor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies a voltage (5 V) to the room temperature sensor and reads voltage changes as changes in the resistance of the room temperature sensor.

DTC No.
DTC Detection Condition
Trouble Area
B1411/11
Open or short in room temperature sensor circuit
  1. Room temperature sensor (for front)
  2. Wire harness between room temperature sensor and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E158847E01


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG) and turn the Techstream main switch on.

  1. Select the item below in the Data List, and read the value displayed on the Techstream.

    Data List / Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual room temperature is displayed
    Open in circuit: -6.5°C (20.3°F)
    Short in circuit: 57.25°C (135.05°F)

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.INSPECT ROOM TEMPERATURE SENSOR


    E158845E01
  1. Remove the room temperature sensor (for front) .

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D26-1 (+) - D26-2 (-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    D26-1 (+) - D26-2 (-)
    15°C (59°F)
    2.45 to 2.88 kΩ
    D26-1 (+) - D26-2 (-)
    20°C (68°F)
    1.95 to 2.30 kΩ
    D26-1 (+) - D26-2 (-)
    25°C (77°F)
    1.60 to 1.80 kΩ
    D26-1 (+) - D26-2 (-)
    30°C (86°F)
    1.28 to 1.47 kΩ
    D26-1 (+) - D26-2 (-)
    35°C (95°F)
    1.00 to 1.22 kΩ
    D26-1 (+) - D26-2 (-)
    40°C (104°F)
    0.80 to 1.00 kΩ
    D26-1 (+) - D26-2 (-)
    45°C (113°F)
    0.65 to 0.85 kΩ
    D26-1 (+) - D26-2 (-)
    50°C (122°F)
    0.50 to 0.70 kΩ
    D26-1 (+) - D26-2 (-)
    55°C (131°F)
    0.44 to 0.60 kΩ
    D26-1 (+) - D26-2 (-)
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE ROOM TEMPERATURE SENSOR
OK


3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)


    E158846E01
  1. Disconnect the D26 sensor connector.

  1. Disconnect the D37 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D26-1 (+) - D37-29 (TR)
    Always
    Below 1 Ω
    D26-2 (-) - D37-35 (SG-4)
    Always
    Below 1 Ω
    D26-1 (+) - Body ground
    Always
    1 MΩ or higher
    D26-2 (-) - Body ground
    Always
    1 MΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER