DTC B1412/12 Ambient Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1412/12 | Open or short in ambient temperature sensor circuit |
|

| 1.READ VALUE USING TECHSTREAM (AMBI TEMP SENS) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream main switch on.
Select the item below in the Data List, and read the value displayed on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature is displayed | Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F) |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT AMBIENT TEMPERATURE SENSOR |
![]() |
Remove the ambient temperature sensor .
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A7-1 - A7-2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| A7-1 - A7-2 | 15°C (59°F) | 2.45 to 2.88 kΩ |
| A7-1 - A7-2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| A7-1 - A7-2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| A7-1 - A7-2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| A7-1 - A7-2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| A7-1 - A7-2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| A7-1 - A7-2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| A7-1 - A7-2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| A7-1 - A7-2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| A7-1 - A7-2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the A7 sensor connector.
Disconnect the D37 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A7-1 - D37-5 (TAM) | Always | Below 1 Ω |
| A7-2 - D37-13 (SG-2) | Always | Below 1 Ω |
| D37-5 (TAM) - Body ground | Always | 10 kΩ or higher |
| D37-13 (SG-2) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||