DTC B1413/13 Evaporator Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1413/13 | Open or short in evaporator temperature sensor circuit |
|

| 1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream main switch on.
Select the item below in the Data List, and read the value displayed on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Evaporator Fin Temperature | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.6°C (139.28°F) | Actual evaporator temperature is displayed | Open circuit: -29.7°C (-21.46°F) Short circuit: 59.6°C (139.28°F) |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) |
Remove the No. 1 cooler thermistor from the front evaporator.

Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| 1 - 2 | -5°C (23°F) | 5.65 to 6.95 kΩ |
| 1 - 2 | 0°C (32°F) | 4.40 to 5.35 kΩ |
| 1 - 2 | 5°C (41°F) | 3.40 to 4.15 kΩ |
| 1 - 2 | 10°C (50°F) | 2.70 to 3.25 kΩ |
| 1 - 2 | 15°C (59°F) | 2.14 to 2.58 kΩ |
| 1 - 2 | 20°C (68°F) | 1.71 to 2.05 kΩ |
| 1 - 2 | 25°C (77°F) | 1.38 to 1.64 kΩ |
| 1 - 2 | 30°C (86°F) | 1.11 to 1.32 kΩ |
|
| ||||
| OK | |
| 3.INSPECT AIR CONDITIONING HARNESS |
Remove the air conditioning harness.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z17-6 (TEA) - 2 | Always | Below 1 Ω |
| z17-5 (SGA) - 1 | Always | Below 1 Ω |
| z17-6 (TEA) - Body ground | Always | 10 kΩ or higher |
| z17-5 (SGA) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||