AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Blower Motor Circuit |

| 1.PERFORM ACTIVE TEST USING TECHSTREAM (BLOWER MOTOR) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream main switch on.
Select the item below in the Active Test, and then check that the blower motor operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Result | Proceed to |
| NG (blower motor does not operate) | A |
| NG (blower motor operates but does not change speed) | B |
| OK | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT FUSE (HTR) |
Remove the HTR-H fuse from the main body ECU.
Measure the resistance of the HTR-H fuse.
| Tester Connection | Condition | Specified Condition |
| HTR fuse | Always | Below 1 Ω |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND) |
![]() |
Disconnect the D34 motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D34-1 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY) |
![]() |
Disconnect the D34 motor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D34-3 (+B) - Body ground | Always | 11 to 14 V |
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND) |
![]() |
Disconnect the D37 amplifier connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D37-23 (BLW) - D37-14 (GND) | Power switch on (IG) Blower switch OFF | 4.5 to 5.5 V |
|
| ||||
| OK | |
| 6.CHECK AIR CONDITIONING AMPLIFIER |
![]() |
Remove the air conditioning amplifier with its connectors still connected.
Check the waveform at the amplifier connector.
| Item | Content |
| Tester Connection | BLW (D37-23) - GND (D37-14) |
| Tool Setting | 1 V/DIV., 500 μsec./DIV. |
| Condition | Power switch on (IG) Blower switch LO |
|
| ||||
| OK | ||
| ||