Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)

AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > Blower Motor Circuit

for Preparation Click here


DESCRIPTION

The blower motor is operated by signals from the air conditioning amplifier. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM


E160592E02


INSPECTION PROCEDURE

1.PERFORM ACTIVE TEST USING TECHSTREAM (BLOWER MOTOR)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG) and turn the Techstream main switch on.

  1. Select the item below in the Active Test, and then check that the blower motor operates.

    Active Test / Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -

    Result:

    Result
    Proceed to
    NG (blower motor does not operate)
    A
    NG (blower motor operates but does not change speed)
    B
    OK
    C



B
Go to step 5

C
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)
A


2.INSPECT FUSE (HTR)
  1. Remove the HTR fuse from the main body ECU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    HTR fuse
    Always
    Below 1 Ω



NG
REPLACE FUSE
OK


3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND)


    E115959E17
  1. Disconnect the D34 motor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D34-1 (GND) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY)


    E115959E18
  1. Disconnect the D34 motor connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D34-3 (+B) - Body ground
    Power switch on (IG)
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND)


    E143742E75
  1. Disconnect the D37 amplifier connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    D37-23 (BLW) - D37-14 (GND)
    Power switch on (IG)
    Blower switch OFF
    4.5 to 5.5 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK AIR CONDITIONING AMPLIFIER


    E127572E03
  1. Remove the air conditioning amplifier with its connectors still connected .

  1. Check the waveform of the amplifier connector.

    OK:
    Waveform is as shown in the illustration.

    HINT:
    The waveform varies with the blower level.

    Item
    Content
    Tester Connection
    D37-23 (BLW) - D37-14 (GND)
    Tool Setting
    1 V/DIV., 500 μsec./DIV.
    Condition
    Power switch on (IG)
    Blower switch LO



NG
REPLACE AIR CONDITIONING AMPLIFIER
OK

REPLACE BLOWER W/ FAN MOTOR SUB-ASSEMBLY