AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > SYSTEM DESCRIPTION |
| GENERAL |
The air conditioning system has the following features:
| MODE POSITION AND DAMPER OPERATION |

| Control Damper | Control Position | Damper Position | Operation | ||
| Air Inlet Control Damper | FRESH | A | Brings in fresh air | ||
| RECIRC | B | Recirculates internal air | |||
| Air Mix Control Damper (Left/Right Independent Control) | Driver and Front Passenger Side | MAX COOL to MAX HOT (TEMP. SETTING 18 to 32°C (65 to 85°F)) | C, D, E | Varies mixture ratio of fresh air and recirculation air in order to regulate temperature continuously from HOT to COOL | |
| Mode Control Film Damper | Driver and Front Passenger Side | ![]() FACE | I, J, L, O, U | Air blows out of center registers and side registers. | |
![]() BI-LEVEL | I, M, Q, R, T | Air mainly blows out of center registers, side registers, and footwell register ducts. | |||
![]() FOOT | H, K, N, P, S | Air mainly blows out of front and rear footwell register ducts. In addition, air blows out slightly from front and side defrosters, and side registers. | |||
![]() FOOT/DEF | G, K, N, P, S | Air mainly blows out of front and side defrosters to defrost windshield. Air also blows out from front and rear footwell register ducts, and side registers. | |||
![]() DEF | F, K, N, U, V | Air blows out of front and side defrosters and side registers to defrost windshield. | |||

| Control Damper | Control Position | Damper Position | Operation |
| Air Mix Control Damper | MAX COOL to MAX HOT TEMP. SETTING 18 to 32°C (65 to 90°F) | D, E | Varies mixture ratio of fresh air and recirculation air in order to regulate temperature continuously from HOT to COOL |
| Mode Control Film Damper | ![]() FACE | A | Air blows out of roof face ducts. |
![]() BI-LEVEL | B | Air blows out of roof face ducts and rear foot ducts. | |
![]() FOOT | C | Air blows out of rear foot ducts. |
| AIR OUTLET AND AIRFLOW VOLUME |

| Air Outlet Mode | Air Outlet Position Symbol | |||||
| A | B | C | D | E | ||
| Center Face | Side Face | Foot | Footwell | Defroster | ||
![]() | FACE | ![]() | ![]() | - | - | - |
![]() | BI-LEVEL | ![]() | ![]() | ![]() | ![]() | - |
![]() | FOOT | - | ![]() | ![]() | ![]() | ![]() |
![]() | FOOT/DEF | - | ![]() | ![]() | ![]() | ![]() |
![]() | DEF | - | ![]() | - | - | ![]() |

| Air Outlet Mode | Air Outlet Position Symbol | ||
| A | B | ||
| Side Face | Rear Foot | ||
![]() | FACE | ![]() | - |
![]() | BI-LEVEL | ![]() | ![]() |
![]() | FOOT | - | ![]() |
| Air Conditioning Control Assembly |
For both the front and rear manual and automatic air conditioning, the blower motor speed is steplessly adjustable. Pulse type control is used.
The multi-information display is used as the automatic air conditioning display.
| Air Conditioning Unit |
Front Air Conditioning Unit
The front air conditioning unit consists of the evaporator, heater core, servo motors, evaporator temperature sensor, and blower motor.
Rear Air Conditioning Unit
The rear air conditioning unit consists of the evaporator, heater core, air mix control servo motor, mode control servo motor, evaporator temperature sensor, and rear blower motor.

Evaporator
For the evaporator, placing the tanks at the top and the bottom and adopting a micropore tube construction have realized the following effects:
Evaporator Temperature Sensor
The evaporator temperature sensors (No. 1 cooler thermistor for the front air conditioning unit and the rear air conditioning harness for the rear air conditioning unit) each detect the temperature of the cool air immediately past the evaporator based on changes in the resistance of the built-in thermistor. The signal is used by the air conditioning amplifier.
Heater Core

A compact, lightweight, and highly efficient SFA (Straight Flow Aluminum)-II type heater core is used for the front and rear air conditioning units.
Blower Motor
The front blower motor has a built-in blower controller, and the motor speed is controlled by the air conditioning amplifier using duty control.
The rear blower motor speed is controlled by the air conditioning amplifier via a blower motor controller using duty control.
Air Conditioning Harness
The BUS connectors (in the air conditioning harness) have built-in driver ICs that communicate with each servo motor, actuate the servo motor, and have a position detection function. This enables bus communication for the servo motor wire harness, lightweight construction and a reduced number of wires.

Servo Motor
Pulse pattern type servo motors are used. Each servo motor assembly consists of a printed circuit board and a servo motor. The printed circuit board has three contact points, and can transmit two signals (either ON or OFF) using the differing pulse phases. The BUS connector can detect the damper position and movement direction with this signal.

| Condenser |
The condenser consists of two cooling portions: a condensing portion and a super-cooling portion. The condenser also has an integrated gas-liquid separator (modulator). This condenser uses the sub-cool cycle, offering excellent heat-exchange performance.

![]() |
Service Tip
The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system is recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system would be affected. If the system is overcharged with refrigerant, this will also lead to reduced performance. For the proper method of verifying the amount of the refrigerant and for instructions on how to recharge the system with refrigerant.
| Compressor with Motor Assembly |
General

Construction
| Room Temperature Sensor and Humidity Sensor |
The availability of the room temperature sensor and room temperature sensor with built in humidity sensor is as follows.
| Item | Equipment | ||
| Room Temperature Sensor | Room Temperature with built in Humidity Sensor | ||
| Front A/C | Manual | X | - |
| Automatic | X | X | |
| Rear A/C | Manual | - | - |
| Automatic | X | - | |
The room temperature sensors detect the room temperature based on changes in the resistance of the built-in thermistor. The signals are used by the air conditioning amplifier.
If equipped with automatic air conditioning, a humidity sensor function is added to the room temperature sensor for the front. By enabling the detection of humidity in the vehicle interior, this function optimizes the amount of dehumidification effort during the operation of the air conditioning system. As a result, the power consumption of the compressor has been reduced and a comfortable level of humidity has been realized in the vehicle interior.
The humidity-sensing resistance film that is built into the humidity sensor absorbs and releases the humidity in the vehicle interior. During the absorption and releasing processes, the humidity-sensing resistance film expands (during the absorption of humidity) and contracts (during drying). The clearance between the carbon particles in the humidity-sensing resistance film expands and contracts during absorption and drying, thus changing the resistance between the electrodes. The air conditioning amplifier determines the humidity in the vehicle interior through the changes in the output voltage of the humidity sensor that are caused by the resistance between the electrodes.

| Ambient Temperature Sensor |
The ambient temperature sensor detects the ambient temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier.
| Heater Water Pump |
![]() |
A heater water pump is used to circulate coolant for the heater core. This provides stable heater performance even if the engine is stopped due to THS-II control.
A pump with low resistance to water flow is used.
| Solar Sensor |

The solar sensor* consists of a photo diode, two amplifier circuits for the solar sensor, and a frequency converter circuit for the light control sensor.
The solar sensor detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight from its LH and RH sides (2 directions) and outputs these sunlight strength signals to the air conditioning amplifier.
| Neural Network Control |

In conventional automatic air conditioning systems without neural network control, the air conditioning amplifier determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can be felt comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for performing a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier. The air conditioning amplifier can then perform control to provide enhanced air conditioning comfort.
The neural network control consists of neurons in the input layer, intermediate layer, and output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume, and outlet mode control volume. Accordingly, the air conditioning amplifier controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.
| Compressor Control (Compressor Speed Control) |
The air conditioning amplifier calculates the target compressor speed based on the target evaporator temperature (calculated using the room temperature sensor, humidity sensor*, ambient temperature sensor, and solar sensor*) and the actual evaporator temperature detected by the evaporator temperature sensor. Then, the air conditioning amplifier transmits the target compressor speed to the hybrid vehicle control ECU. The hybrid vehicle control ECU controls the air conditioning inverter based on the target speed data. This control is performed in order make the compressor operate at a speed that suits the operating conditions of the air conditioning system.
The air conditioning amplifier calculates the target evaporator temperature, which includes corrections based on the vehicle interior humidity (obtained from the humidity sensor)* and the windshield glass inner surface humidity (calculated using the humidity sensor*, solar sensor*, room temperature sensor, mode damper position, and wiper operation condition). Accordingly, the air conditioning amplifier controls the compressor speed to an extent that does not inhibit the proper cooling performance or defogging performance. As a result, comfort and low fuel consumption can be realized.