ENGINE IMMOBILISER SYSTEM > Security Indicator Light Circuit |

| 1.PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY INDICATOR LIGHT) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Select the following menu items: Body Electrical / Smart Key / Active Test.
Perform the Active Test according to the display on the Techstream.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Security Indic | Security indicator light | ON/OFF | - |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - INTEGRATION CONTROL AND PANEL) |
![]() |
Disconnect the certification ECU (smart key ECU assembly) and integration control and panel connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D40-2 (IND) - E19-2 (IND+) | Always | Below 1 Ω |
| D40-2 (IND) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (INTEGRATION CONTROL AND PANEL - BODY GROUND) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E19-5 (E) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||