Home › SECURITIES › ENGINE IMMOBILISER › ENGINE IMMOBILISER SYSTEM

ENGINE IMMOBILISER SYSTEM > Security Indicator Light Circuit

for Preparation Click here


DESCRIPTION

The security indicator light blinks continuously due to a continuous signal received from the certification ECU (smart key ECU assembly) while in the armed state.

WIRING DIAGRAM


B178835E03


INSPECTION PROCEDURE

NOTICE:
If the certification ECU (smart key ECU assembly) is replaced, register the key and ECU communication ID (Click here).

1.PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY INDICATOR LIGHT)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the Techstream on.

  1. Select the following menu items: Body Electrical / Smart Key / Active Test.

  1. Perform the Active Test according to the display on the Techstream.

    Smart Key (Certification ECU (Smart Key ECU Assembly)): 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Security Indic
    Security indicator light
    ON/OFF
    -

    OK:
    The security indicator light turns on or off according to the Techstream operation.



NG
Go to step 2
OK

REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) (Click here)  

2.CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - INTEGRATION CONTROL AND PANEL)


    B178825E02
  1. Disconnect the certification ECU (smart key ECU assembly) and integration control and panel connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D40-2 (IND) - E19-2 (IND+)
    Always
    Below 1 Ω
    D40-2 (IND) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (INTEGRATION CONTROL AND PANEL - BODY GROUND)


    B164265E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    E19-5 (E) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE INTEGRATION CONTROL AND PANEL ASSEMBLY (Click here)