AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > IG Power Source Circuit |

| 1.INSPECT FUSE (A/C NO. 2) |
Remove the A/C No. 2 fuse from the instrument panel junction block.
Measure the resistance of the fuse.
| Tester Connection | Condition | Specified Condition |
| A/C NO. 2 fuse | Always | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY) |
![]() |
Disconnect the D37 amplifier connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D37-1 (IG+) - Body ground | Power switch on (IG) | 11 to 14 V |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND) |
![]() |
Disconnect the D37 and D38 amplifier connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D37-14 (GND) - Body ground | Always | Below 1 Ω |
| D38-20 (GND2)* - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||