AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > Back-up Power Source Circuit |

| 1.INSPECT FUSE (ECU-B) |
Remove the ECU-B fuse from the engine room No. 1 relay block.
Measure the resistance of the fuse.
| Tester Connection | Condition | Specified Condition |
| ECU-B fuse | Always | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY) |
![]() |
Disconnect the D37 and D38 amplifier connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D37-21 (B) - Body ground | Always | 11 to 14 V |
| D38-24 (+B2)* - Body ground | Always | 11 to 14 V |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND) |
![]() |
Disconnect the D37 and D38 amplifier connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D37-14 (GND) - Body ground | Always | Below 1 Ω |
| D38-20 (GND2)* - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||