Home › BODY ELECTRICAL › DOOR LOCK › DOOR CONTROL SWITCH

DOOR CONTROL SWITCH > INSPECTION

for Preparation Click here



1. INSPECT POWER WINDOW MASTER SWITCH


    B164359E13
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Locked
    Below 1 Ω
    1 - 2
    1 - 9
    OFF (Free)
    10 kΩ or higher
    1 - 9
    Unlocked
    Below 1 Ω

    If the result is not specified, replace power window master switch.



2. INSPECT DOOR CONTROL SWITCH ASSEMBLY


B171374E01
Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection
Switch Condition
Specified Condition
4 - 3
Locked
Below 1 Ω
4 - 3
2 - 3
OFF (Free)
10 kΩ or higher
2 - 3
Unlocked
Below 1 Ω

If the result is not specified, replace door control switch assembly.