POWER STEERING SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Turn the power switch off.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Chassis / EMPS / Data List.
According to the display on the tester, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Meter Vehicle Velocity | Vehicle speed from meter: Min.: 0 km/h (0 mph) Max.: 300 km/h (187.5 mph) | 0 km/h (0 mph) | Vehicle stopped |
| No significant fluctuation | Vehicle driven at constant speed | ||
| Motor Actual Current | Amount of current to motor: Min.: -327.68 A Max.: 327.67 A | Value changes in proportion to steering effort | Power steering is in operation |
| Command Value Current | Demanded amount of current to motor: Min.: -327.68 A Max.: 327.68 A | Value changes in proportion to steering effort | Power steering is in operation |
| Steering Angle Velocity | Steering angle speed: Min.: -32768 deg/s Max.: 32767 deg/s | Value changes in proportion to steering effort | Steering wheel is turned |
| Thermistor Temperature | ECU substrate temperature: Min.: -40°C Max.: 150°C | -40 to 150°C | Power switch on (IG) |
| PIG Power Supply | Power source voltage to activate motor: Min.: 0 V Max.: 20.1531 V | 11 to 14 V | Power steering is in operation |
| IG Power Supply | ECU power source voltage: Min.: 0 V Max.: 20.1531 V | 11 to 14 V | Power switch on (IG) |
| Steering Wheel Torque | Steering wheel torque: Min.: -327.68 Nm Max.: 7 Nm | Value changes in proportion to steering effort | Power switch on (IG) and power steering is in operation |
| Motor Rotation Angle | Motor rotation angle: Min.: 0 deg Max.: 360 deg | During steering operation, motor rotation angle value changes from 0 to 360° | Power steering is in operation |
| Motor Voltage | Motor power supply voltage: Min.:0 V Max.: 45.955 V | 11 to 14 V | Power steering is in operation |
| Motor Terminal Volt(U) | Motor terminal voltage (U phase): Min.: 0 V Max.: 46.667 V | When the steering wheel is turned, a voltage between 1 V and approximately 1 V less than the battery voltage is displayed. | Engine running and steering wheel is turned |
| Motor Terminal Volt(V) | Motor terminal voltage (V phase): Min.: 0 V Max.: 46.667 V | When the steering wheel is turned, a voltage between 1 V and approximately 1 V less than the battery voltage is displayed. | Engine running and steering wheel is turned |
| Motor Terminal Volt(W) | Motor Terminal voltage (W phase): Min.: 0 V Max.: 46.667 V | When the steering wheel is turned, a voltage between 1 V and approximately 1 V less than the battery voltage is displayed. | Engine running and steering wheel is turned |
| IG ON/OFF Times | Power switch ON/OFF number of times after fail detection: Min.: 0 times Max.: 65535 times | - | - |
| Motor Overheat Record | Continuous overheat prevention control record: Unrec or Rec | Unrec | - |
| Motor Lo Power Record | PIG power source voltage drop record: Unrec or Rec | Unrec | - |
| Eng Rev Inter Record | Record of engine revolution signal interruption Unrec or Rec | Unrec | - |
| Spd Sig Invalid Record | Record of vehicle speed signal invalid: Unrec or Rec | Unrec | - |
| Battery Voltage Lo Record | Number of battery voltage drop record: Min.: 0 time Max.: 65535 times | - | - |
| Battery Voltage | Battery voltage: Min.: 0 V Max.: 25.5 V | 11 to 14 V | - |
| PS Assist Signal | Power steering assist signal: ON or OFF | ON: Power steering assist signal is sent | Power switch on (IG) and steering wheel is turned |
| OFF: Power steering assist signal is not sent | No steering load (in neutral position) | ||
| Ready Status | Ready signal status: OFF or Ready | OFF: Power switch off Ready: Power switch on (READY) | - |
| The Number of DTCs | Number of detected DTCs when freeze frame data stored: Min.: 0 Max.: 255 | - | - |
| ACTIVE TEST |
Turn the power switch off.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body / Combination Meter / Active Test.
According to the display on the tester, perform the "Active Test".
| Tester Display | Test Part | Control Range | Control Range |
| Indicat. EPS (*1) | P/S Warning Light | ON or OFF | Confirm that vehicle is stopped, engine idling |
| Master Warning (*2) | Master Warning Light | ON or OFF | Confirm that vehicle is stopped, engine idling |