| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Meter Vehicle Velocity | Vehicle speed from meter: Min.: 0 km/h (0 mph) Max.: 300 km/h (187.5 mph) | 0 km/h (mph) | Vehicle stopped |
| No significant fluctuation | Vehicle driven at a constant speed | ||
| Engine Revolution | Shows the engine speed: Min.: 0 rpm Max.: 12800 rpm | No significant fluctuation | Engine is running at a constant speed |
| Motor Actual Current | Amount of current to motor: Min.: -327.68 A Max.: 327.67 A | Value changes in proportion to steering effort | Power steering is in operation |
| Command Value Current | Demanded amount of current to motor: Min.: -327.68 A Max.: 327.68 A | Value changes in proportion to steering effort | Power steering is in operation |
| Steering Angle Velocity | Steering angle speed: Min.: -32768°/sec. Max.: 32767°/sec. | Value changes in proportion to steering effort | Steering wheel is turned |
| Thermistor Temperature | ECU substrate temperature: Min.: -40°C Max.: 150°C | -40 to 150°C | Power switch on (IG) |
| PIG Power Supply | Power source voltage to activate motor: Min.: 0 V Max.: 20.1531 V | 11 to 14 V | Power steering is in operation |
| IG Power Supply | ECU power source voltage: Min.: 0 V Max.: 20.1531 V | 11 to 14 V | Power switch on (IG) |
| Motor Rotation Angle | Motor rotation angle: Min.: 0° Max.: 360° | During steering operation, motor rotation angle value changes from 0 to 360° | Power steering is in operation |
| Motor Voltage | Motor power supply voltage: Min.: 0 V Max.: 45.955 V | 11 to 14 V | Power steering is in operation |
| Motor Terminal Volt(U) | Motor terminal voltage (U phase): Min.: 0 V Max.: 46.667 V | When the steering wheel is turned, a voltage between 1 V and approximately 1 V less than the battery voltage is displayed. | Engine running and steering wheel is turned |
| Motor Terminal Volt(V) | Motor terminal voltage (V phase): Min.: 0 V Max.: 46.667 V | When the steering wheel is turned, a voltage between 1 V and approximately 1 V less than the battery voltage is displayed. | Engine running and steering wheel is turned |
| Motor Terminal Volt(W) | Motor Terminal voltage (W phase): Min.: 0 V Max.: 46.667 V | When the steering wheel is turned, a voltage between 1 V and approximately 1 V less than the battery voltage is displayed. | Engine running and steering wheel is turned |
| Battery Voltage | Battery voltage: Min.: 0 V Max.: 25.5 V | 11 to 14 V | - |
| PS Assist Signal | Power steering assist signal: ON or OFF | ON: Power steering assist signal is sent | Power switch on (IG) and steering wheel is turned |
| OFF: Power steering assist signal is not sent | No steering load (in centered position) |