Home › BODY ELECTRICAL › LIGHTING › ROOM LIGHT ASSEMBLY (for Center)

ROOM LIGHT ASSEMBLY (for Center) > INSPECTION

for Preparation Click here



1. INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Standard)


    E151683E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Q2-2 - Body ground
    Always
    Below 1 Ω

    If the result is not as specified, repair or replace harness or connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    Q2-1 - Body ground
    Always
    11 to 14 V

    If the result is not as specified, repair or replace the harness or connector.



2. INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Independent Type)


    E151690E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    LH Side:
    Tester Connection
    Condition
    Specified Condition
    Q4-3 - Body ground
    Always
    Below 1 Ω
    RH Side:
    Tester Connection
    Condition
    Specified Condition
    Q3-3 - Body ground
    Always
    Below 1 Ω

    If the result is not as specified, repair or replace harness or connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    LH Side:
    Tester Connection
    Condition
    Specified Condition
    Q4-2 - Body ground
    Always
    11 to 14 V
    RH Side:
    Tester Connection
    Condition
    Specified Condition
    Q3-2 - Body ground
    Always
    11 to 14 V

    If the result is not as specified, repair or replace the harness or connector.