ROOM LIGHT ASSEMBLY (for Center) > INSPECTION |
| 1. INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Standard) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q2-2 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q2-1 - Body ground | Always | 11 to 14 V |
| 2. INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Independent Type) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q4-3 - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| Q3-3 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q4-2 - Body ground | Always | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
| Q3-2 - Body ground | Always | 11 to 14 V |