Home › ENGINE › 3MZ-FE STARTING › SMART KEY SYSTEM

SMART KEY SYSTEM > Power Source Mode does not Change

for Preparation Click here


DESCRIPTION

When the power switch is pushed with the electrical key in the cabin, the main body ECU (instrument panel junction block) receives signals to switch the power source mode.

HINT:
To allow use of Techstream to inspect the push-button start function when the power switch is off, repeat opening and closing any of the doors. Opening and closing a door establishes communication between Techstream and the main body ECU (instrument panel junction block). (Opening and closing a door can also be simulated by operating a door courtesy light switch.)


WIRING DIAGRAM


B177113E03


B177114E01


INSPECTION PROCEDURE

1.CHECK SMART KEY SYSTEM


  1. Remove the battery of the electrical key transmitter (Click here).


    B183999E01

  1. Touch the logo side mark of the key or card key to the power switch.

  1. Check that the power switch can be turned on (IG).

    Result:

    Result
    Proceed to
    Power source mode does not change to on (ACC)
    A
    Power source mode does not change to on (IG)
    B
    Power source mode does not change to on (IG and ACC)
    C
    Power source mode is turned on
    D



B
Go to step 4

C
Go to step 10

D
GO TO SMART KEY SYSTEM (ROOM OSCILLATOR DOES NOT RECOGNIZE KEY) (Click here)
A


2.INSPECT ACC RELAY


    A169410
  1. Remove the ACC relay from the instrument panel junction block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    When battery voltage is not applied to terminals 1 and 2
    10 kΩ or higher
    3 - 5
    When battery voltage is applied to terminals 1 and 2
    Below 1 Ω



NG
REPLACE ACC RELAY
OK


3.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - INSTRUMENT PANEL JUNCTION BLOCK)


  1. Disconnect the D8 connector from the main body ECU (instrument panel junction block).


    B138001E30

  1. Disconnect the 1I connector from the instrument panel junction block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D8-22 (ACCD) - 1I-3
    Always
    Below 1 Ω
    D8-22 (ACCD) or 1I-3 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK) 

4.INSPECT IG1 RELAY


    A169410
  1. Remove the IG1 relay from the instrument panel junction block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    When battery voltage is not applied to terminals 1 and 2
    10 kΩ or higher
    3 - 5
    When battery voltage is applied to terminal 1 and 2
    Below 1 Ω



NG
REPLACE IG1 RELAY
OK


5.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - INSTRUMENT PANEL JUNCTION BLOCK)


  1. Disconnect the D8 connector from the main body ECU (instrument panel junction block).


    B138001E29

  1. Disconnect the 1I connector from the instrument panel junction block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D8-3 (IG1D) - 1I-9
    Always
    Below 1 Ω
    D8-3 (IG1D) or 1I-9 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.INSPECT IG2 RELAY


    B016200E23
  1. Remove the IG2 relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    When battery voltage is not applied to terminals 1 and 2
    10 kΩ or higher
    3 - 5
    When battery voltage is applied to terminal 1 and 2
    Below 1 Ω



NG
REPLACE IG2 RELAY
OK


7.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - IG2 RELAY)


  1. Disconnect the D7 connector from the main body ECU (instrument panel junction block).


    B176772E01

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D7-11 (IG2D) - Engine room relay block IG2 relay terminal 1
    Always
    Below 1 Ω
    D7-11 (IG2D) or Engine room relay block IG2 relay terminal 1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8.CHECK HARNESS AND CONNECTOR (BATTERY - IG2 RELAY)


    B177331E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    Engine room relay block IG2 relay terminal 5 - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR, OR REPLACE IG2 FUSE
OK


9.CHECK HARNESS AND CONNECTOR (IG2 RELAY - BODY GROUND)


    B177331E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Engine room relay block IG2 relay terminal 2 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK) 

10.CHECK HARNESS AND CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK)


    B177332E01
  1. Disconnect the 1A connector from the instrument panel junction block.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    1A-1 - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR, OR REPLACE ALT FUSE
OK


11.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK - BODY GROUND)


    B177333E01
  1. Disconnect the 1F connector from the instrument panel junction block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1F-10 - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK)