Home › HYBRID SYSTEM · P310 › HYBRID TRANSMISSION / TRANSAXLE › SHIFT LEVER

SHIFT LEVER > INSPECTION

for Preparation Click here



1. INSPECT SHIFT LOCK CONTROL ECU


    C168466E03
  1. Disconnect the shift lock control ECU connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    12 (IG) - Body ground
    Power switch on (READY)
    11 to 14 V
    12 (IG) - Body ground
    Power switch off
    Below 1 V
    6 (STP) - Body ground
    Brake pedal depressed
    11 to 14 V
    6 (STP) - Body ground
    Brake pedal released
    Below 1 V

    If the result is not as specified, replace the shift lock control unit.



    C168466E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 (E) - Body ground
    Always
    Below 1 Ω

    If the result is not as specified, replace the shift lock control unit.



2. INSPECT SHIFT LOCK SOLENOID
  1. Disconnect the shift lock solenoid connector.



    C159129E01
  1. Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.

    Standard resistance:
    Tester Connection
    Shift Position
    Specified Condition
    1 (P) - 2 (E2)
    P
    10 kΩ or higher
    1 (P) - 2 (E2)
    Except P
    Below 1 Ω

    If the result is not as specified, replace the shift lock control unit.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 (SLS-) - 4 (SLS+)
    Always
    112 Ω