SHIFT LEVER > INSPECTION |
| 1. INSPECT SHIFT LOCK CONTROL ECU |
![]() |
Disconnect the shift lock control ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 12 (IG) - Body ground | Power switch on (READY) | 11 to 14 V |
| 12 (IG) - Body ground | Power switch off | Below 1 V |
| 6 (STP) - Body ground | Brake pedal depressed | 11 to 14 V |
| 6 (STP) - Body ground | Brake pedal released | Below 1 V |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (E) - Body ground | Always | Below 1 Ω |
| 2. INSPECT SHIFT LOCK SOLENOID |
Disconnect the shift lock solenoid connector.
![]() |
Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.
| Tester Connection | Shift Position | Specified Condition |
| 1 (P) - 2 (E2) | P | 10 kΩ or higher |
| 1 (P) - 2 (E2) | Except P | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (SLS-) - 4 (SLS+) | Always | 112 Ω |