Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1417/17    Rear Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The rear air conditioning harness (rear evaporator temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the rear air conditioner. It sends signals to the air conditioning amplifier. The signals change in accordance with the resistance of the rear air conditioning harness (rear evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5 V) to the rear air conditioning harness (rear evaporator temperature sensor) and reads voltage changes as changes in the resistance of the rear air conditioning harness (rear evaporator temperature sensor). This sensor is used for frost prevention.

DTC No.
DTC Detection Condition
Trouble Area
B1417/17
Open or short in rear air conditioning harness circuit (rear evaporator temperature sensor)
  1. Rear air conditioning harness (rear evaporator temperature sensor)
  2. Wire harness between rear air conditioning harness (rear evaporator temperature sensor) and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E127591E03


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG) and turn the Techstream main switch on.

  1. Select the item below in the Data List, and read the value displayed on the Techstream.

    Data List / Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sens(Rear)
    Rear evaporator temperature sensor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.6°C (139.28°F)
    Actual rear evaporator temperature is displayed
    Open circuit: -29.7°C (-21.46°F)
    Short circuit: 59.6°C (139.28°F)

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A


2.INSPECT REAR AIR CONDITIONING HARNESS (REAR EVAPORATOR TEMPERATURE SENSOR)


    E127592E06
  1. Remove the rear air conditioning harness.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N12-7 (-) - N12-8 (+)
    -10°C (14°F)
    7.30 to 9.10 kΩ
    N12-7 (-) - N12-8 (+)
    -5°C (23°F)
    5.65 to 6.95 kΩ
    N12-7 (-) - N12-8 (+)
    0°C (32°F)
    4.40 to 5.35 kΩ
    N12-7 (-) - N12-8 (+)
    5°C (41°F)
    3.40 to 4.15 kΩ
    N12-7 (-) - N12-8 (+)
    10°C (50°F)
    2.70 to 3.25 kΩ
    N12-7 (-) - N12-8 (+)
    15°C (59°F)
    2.14 to 2.58 kΩ
    N12-7 (-) - N12-8 (+)
    20°C (68°F)
    1.71 to 2.05 kΩ
    N12-7 (-) - N12-8 (+)
    25°C (77°F)
    1.38 to 1.64 kΩ
    N12-7 (-) - N12-8 (+)
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
    2. When measuring, the thermistor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE REAR AIR CONDITIONING HARNESS
OK


3.CHECK HARNESS AND CONNECTOR (REAR AIR CONDITIONING HARNESS - AIR CONDITIONING AMPLIFIER)


    E153085E04
  1. Disconnect the N12 rear air conditioning harness connector.

  1. Disconnect the D38 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N12-8 (+) - D38-4 (TEC)
    Always
    Below 1 Ω
    N12-7 (-) - D38-19 (SGND)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER (Click here)