DTC B1419/19 Rear Room Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1419/19 | Open or short in rear room temperature sensor circuit |
|

| 1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream main switch on.
Select the item below in the Data List, and read the value displayed on the Techstream.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temp Sensor(Rear) | Rear room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual rear room temperature is displayed | Open circuit: -6.5°C (20.3°F) Short circuit: 57.25°C (135.05°F) |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT REAR ROOM TEMPERATURE SENSOR |
![]() |
Remove the rear room temperature sensor .
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| N13-1 (+) - N13-2 (-) | 10°C (50°F) | 3.00 to 3.73 kΩ |
| N13-1 (+) - N13-2 (-) | 15°C (59°F) | 2.45 to 2.88 kΩ |
| N13-1 (+) - N13-2 (-) | 20°C (68°F) | 1.95 to 2.30 kΩ |
| N13-1 (+) - N13-2 (-) | 25°C (77°F) | 1.60 to 1.80 kΩ |
| N13-1 (+) - N13-2 (-) | 30°C (86°F) | 1.28 to 1.47 kΩ |
| N13-1 (+) - N13-2 (-) | 35°C (95°F) | 1.00 to 1.22 kΩ |
| N13-1 (+) - N13-2 (-) | 40°C (104°F) | 0.80 to 1.00 kΩ |
| N13-1 (+) - N13-2 (-) | 45°C (113°F) | 0.65 to 0.85 kΩ |
| N13-1 (+) - N13-2 (-) | 50°C (122°F) | 0.50 to 0.70 kΩ |
| N13-1 (+) - N13-2 (-) | 55°C (131°F) | 0.44 to 0.60 kΩ |
| N13-1 (+) - N13-2 (-) | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the N13 sensor connector.
Disconnect the D38 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| N13-1 - D38-17 (TR) | Always | Below 1 Ω |
| N13-2 - D38-7 (SG-6) | Always | Below 1 Ω |
| N13-1 - Body ground | Always | 1 MΩ or higher |
| N13-2 - Body ground | Always | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||