DTC P2420 Evaporative Emission System Switching Valve Control Circuit High |
| DTCs | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
| P2420 | Vent valve stuck open (vent) | Vent valve open stuck is detected during EVAP key-off monitor |
| Power switch OFF | 2 trip |

| Required Sensors/Components (Main) | Purge VSV and canister pump module |
| Frequency of Operation | Once per driving cycle |
| Duration | Within 15 minutes |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs are not present | None |
| EVAP key-off monitor runs when all of the following conditions are met: | - |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Below 2.5 mph (4 km/h) |
| Power switch | OFF |
| Engine condition | Not running |
| Canister pressure sensor malfunction (P0450, P0451, P0452 and P0453) | Not detected |
| FTP sensor malfunction (P1451, P1452 and P1453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before power switch off | Conditions 1 and 2 |
| 1. Duration that vehicle is being driven | 5 minutes or more |
| 2. Purge flow | Executed |
| Engine coolant temperature | 4.4 to 35°C (40 to 95°F) |
| Intake air temperature | 4.4 to 35°C (40 to 95°F) |
| Time after engine stopped | 5 hours |
| First time | 7 hours |
| Second time | 9 hours and 30 minutes |
| Next sequence is run if the following condition is met: | - |
| Atmospheric pressure change for 10 seconds | Less than 0.3 kPa (2.25 mmHg) for 1 second |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2 and 3 |
| 1. EVAP pressure 1.9 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated |
| Next sequence is run if the following condition is met: | - |
| EVAP pressure change for 10 seconds after vent valve ON (Closed) | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if the following condition is met: | - |
| Vacuum introduction time | 15 minutes or less |
| Next sequence is run if the following condition is met: | - |
| EVAP pressure change for 10 seconds after purge VSV ON (Open). | 0.3 kPa (2.25 mmHg) or more |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2, 3 and 4 |
| 1. EVAP pressure 1.9 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated |
| 4. Reference pressure difference between the first and second | Less than 0.7 kPa (5.25 mmHg) |
| Next sequence is run if the following condition is met: | - |
| Canister leaks when vacuum introduction was complete | Second reference pressure or less |
| Next sequence is run if both of the following conditions are met: | Conditions 1 and 2 |
| 1. FTP when EVAP monitor started | -2 kPa (-15 mmHg) or less, or 3 kPa (22.5 mmHg) or more |
| 2. FTP change while FVCV and vent valve are open | 0.5 kPa (3.75 mmHg) or more |
| Next sequence is run if both of the following conditions are met: | Conditions 1 and 2 |
| 1. FTP when EVAP monitor started | -2 to 3 kPa (-15 to 22.5 mmHg) |
| 2. Vacuum introduction time | 15 minutes or less |
| Next sequence is run if the following condition is met: | |
| FTP change when vacuum introduction for fuel tank | 0.5 kPa (3.75 mmHg) |
| Next sequence is run if the following condition is met: | |
| FTP change when FVCV closed | 0.35 kPa (2.6 mmHg) or less |
| Next sequence is run if all of the following conditions are met: | Conditions 1, 2, 3, and 4 |
| 1. FTP 1.9 seconds after reference pressure measurement | -1 kPa (-7.5 mmHg) or less |
| 2. Reference pressure | -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) |
| 3. Reference pressure | Saturated |
| 4. Reference pressure difference between the second and third | Less than 0.7 kPa (5.25 mmHg) |
| Sequence is run if the following condition is met: | |
| FTP when vacuum introduction for fuel tank was complete | Less than third reference pressure |
| Next sequence is run if the following condition is met: | - |
| FTP change while FVCV and vent valve are open | Less than 0.3 kPa (2.25 mmHg) |
| Monitor is complete if the following condition is met: | - |
| Atmospheric pressure difference between sequence 1 and 8 | 0.35 kPa (2.6 mmHg) or less |
| EVAP pressure change after EVAP canister vent valve is ON | Less than 0.3 kPa (2.25 mmHg) |