FUEL LID OPENER SYSTEM > TERMINALS OF ECU |
| CHECK HYBRID VEHICLE CONTROL ECU |
Disconnect the B3 and B1 hybrid vehicle control ECU connectors.

Measure the resistance according to the value(s) in the table below.
| Terminal No. (Symbols) | Wiring Color | Terminal Description | Condition | Specified Condition |
| B3-5 (E1) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| B1-28 (E2) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
Reconnect the B3 and B1 hybrid vehicle control ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbols) | Wiring Color | Terminal Description | Condition | Specified Condition |
| D36-11 (FUO) - B3-5 (E1) | L - W-B | Fuel lid motor signal | Fuel lid motor operating | Below 1 V |
| D36-11 (FUO) - B3-5 (E1) | L - W-B | Fuel lid motor signal | Fuel lid motor not operating | 10 to 14 V |
| D35-15 (FUEL) - B3-5 (E1) | P - W-B | Fuel lid opener switch signal input | Power switch on (IG), fuel lid opener switch is pressed | Below 1 V |
| D35-15 (FUEL) - B3-5 (E1) | P - W-B | Fuel lid opener switch signal input | Power switch on (IG), fuel lid opener switch is not pressed | 10 to 14 V |
| D35-13 (LIDO) - B3-5 (E1) | G - W-B | Fuel lid courtesy switch signal input | Power switch on (IG), fuel lid is closed | Below 1 V |
| D35-13 (LIDO) - B3-5 (E1) | G - W-B | Fuel lid courtesy switch signal input | Power switch on (IG), fuel lid is opened | 10 to 14 V |
| D35-7 (LST1) - B3-5 (E1) | R - W-B | Multi-information display signal | Multi-information display displays "PLEASE WAIT NOW OPENING" | Below 1 V |
| D35-6 (LST2) - B3-5 (E1) | GR - W-B | Multi-information display signal | Multi-information display displays "PLEASE WAIT NOW OPENING" | 10 to 14 V |
| D35-7 (LST1) - B3-5 (E1) | R - W-B | Multi-information display signal | Multi-information display displays "REFUEL READY" | 10 to 14 V |
| D35-6 (LST2) - B3-5 (E1) | GR - W-B | Multi-information display signal | Multi-information display displays "REFUEL READY" | 10 to 14 V |
| D35-7 (LST1) - B3-5 (E1) | R - W-B | Multi-information display signal | Multi-information display displays "CLOSE FUEL LID" | 10 to 14 V |
| D35-6 (LST2) - B3-5 (E1) | GR - W-B | Multi-information display signal | Multi-information display displays "CLOSE FUEL LID" | Below 1 V |
| D35-7 (LST1) - B3-5 (E1) | R - W-B | Multi-information display signal | Multi-information display displays "OFF" | Below 1 V |
| D35-6 (LST2) - B3-5 (E1) | GR - W-B | Multi-information display signal | Multi-information display displays "OFF" | Below 1 V |
| D36-35 (PTNK) - B1-28 (E2) | B - BR | Fuel tank pressure sensor signal | Power switch on (IG) | 0.5 to 4.5 V |
| D36-12 (CCV2) - B3-5 (E1) | GR - W-B | Fuel vapor-containment valve signal | Close valve ON (Open) | Below 1 V |
| D36-12 (CCV2) - B3-5 (E1) | GR - W-B | Fuel vapor-containment valve signal | Close valve OFF (Close) | 10 to 14 V |
| CHECK COMBINATION METER |
Disconnect the E1 combination meter connector.

Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbols) | Wiring Color | Terminal Description | Condition | Specified Condition |
| E1-20 (ES) - Body ground | R - Body ground | Ground | Always | Below 1 Ω |
| E1-12 (FUWI) - E1-20 (ES) | L - R | Multi-information display signal | Multi-information display displays "PLEASE WAIT NOW OPENING" | Below 1 V |
| E1-13 (FUCI) - E1-20 (ES) | LG - R | Multi-information display signal | Multi-information display displays "PLEASE WAIT NOW OPENING" | 10 to 14 V |
| E1-12 (FUWI) - E1-20 (ES) | L - R | Multi-information display signal | Multi-information display displays "REFUEL READY" | 10 to 14 V |
| E1-13 (FUCI) - E1-20 (ES) | LG - R | Multi-information display signal | Multi-information display displays "REFUEL READY" | 10 to 14 V |
| E1-12 (FUWI) - E1-20 (ES) | L - R | Multi-information display signal | Multi-information display displays "CLOSE FUEL LID" | 10 to 14 V |
| E1-13 (FUCI) - E1-20 (ES) | LG - R | Multi-information display signal | Multi-information display displays "CLOSE FUEL LID" | Below 1 V |
| E1-12 (FUWI) - E1-20 (ES) | L - R | Multi-information display signal | Multi-information display displays "OFF" | Below 1 V |
| E1-13 (FUCI) - E1-20 (ES) | LG - R | Multi-information display signal | Multi-information display displays "OFF" | Below 1 V |