BRAKE PEDAL > ADJUSTMENT |
| 1. INSPECT AND ADJUST BRAKE PEDAL HEIGHT |
Check the brake pedal height.
![]() |
Turn back the carpet.
Measure the shortest distance between the brake pedal surface and tibia pad.
Adjust the brake pedal height.
Disconnect the stop light switch connector.
Remove the stop light switch assembly.
Loosen the push rod clevis lock nut.
Adjust the brake pedal height by turning the push rod.
Tighten the push rod clevis lock nut.
Install and adjust the stop light switch .
Connect the stop light switch connector.
| 2. ADJUST BRAKE PEDAL STROKE SENSOR |
When installing a new brake pedal stroke sensor assembly:
![]() |
Connect the sensor connector.
Install a new sensor with the 2 bolts.
Firmly depress the brake pedal and break the sensor lever set pin.
Remove the broken lever set pin.
When reusing the brake pedal stroke sensor assembly:
Connect the sensor connector.
![]() |
Temporarily install the sensor with the 2 bolts.
Connect the cable to the negative battery terminal.
Connect the Techstream to the DLC3.
![]() |
Turn the power switch on (IG). Reading the value of the stroke sensor shown in Data List, turn the sensor slowly to the right and left to adjust the output voltage to the standard voltage.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Stroke Sensor | Stroke sensor / min.: 0 V, max.: 5 V | When brake pedal is released: 0.7 to 1.3 V | - |
Tighten the 2 bolts.
Disconnect the cable from the negative battery terminal.
Disconnect the Techstream.
| 3. INSPECT BRAKE PEDAL FREE PLAY |
![]() |
Depress the pedal until a slight resistance is felt. Measure the distance as shown in the illustration.
| 4. INSPECT BRAKE PEDAL RESERVE DISTANCE |
![]() |
Release the parking brake lever.
With the engine running, depress the brake pedal and measure the pedal reserve distance as shown in the illustration.