SOLAR SENSOR > INSPECTION |
| 1. INSPECT SOLAR SENSOR |
![]() |
Remove the A/C solar sensor with the connector still connected.
Apply battery voltage between terminals 6 (CLTB) and 3 (CLTE) of the A/C solar sensor.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F1-1 (TSL) - F1-3 (CLTE) | Sensor is subjected to electric light | 0.8 to 4.3 V |
| F1-1 (TSL) - F1-3 (CLTE) | Sensor is covered by a cloth | Below 0.8 V |
| F1-2 (TSR) - F1-3 (CLTE) | Sensor is subjected to electric light | 0.8 to 4.3 V |
| F1-2 (TSR) - F1-3 (CLTE) | Sensor is covered by a cloth | Below 0.8 V |