Home › BODY ELECTRICAL › OTHER SYSTEM › INVERTER MAIN SWITCH

INVERTER MAIN SWITCH > INSPECTION

for Preparation Click here



1. INSPECT MAIN SWITCH ASSEMBLY


    E153100E01
  1. LED illumination inspection

    1. Connect the (+) lead from the battery to terminal 5 (ILL+) and the (-) lead to terminal 4 (ILL-).

    2. Check that the illumination of the switch comes on.

      OK:
      Tester Connection
      Specified Condition
      5 (ILL+) - 4 (ILL-)
      Night illumination comes on



    E153100E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    3 (INV) - 7 (E)
    Main switch OFF
    10 kΩ or higher
    6 (IG+) - 7 (E)
    Main switch OFF
    10 kΩ or higher
    3 (INV) - 7 (E)
    Main switch ON
    Below 1 Ω
    6 (IG+) - 7 (E)
    Main switch ON
    Below 1 Ω

    1. If the result is not as specified, replace the main switch assembly.