INVERTER MAIN SWITCH > INSPECTION |
| 1. INSPECT MAIN SWITCH ASSEMBLY |
![]() |
LED illumination inspection
Connect the (+) lead from the battery to terminal 5 (ILL+) and the (-) lead to terminal 4 (ILL-).
Check that the illumination of the switch comes on.
| Tester Connection | Specified Condition |
| 5 (ILL+) - 4 (ILL-) | Night illumination comes on |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 3 (INV) - 7 (E) | Main switch OFF | 10 kΩ or higher |
| 6 (IG+) - 7 (E) | Main switch OFF | 10 kΩ or higher |
| 3 (INV) - 7 (E) | Main switch ON | Below 1 Ω |
| 6 (IG+) - 7 (E) | Main switch ON | Below 1 Ω |