DTC P0112 Intake Air Temperature Circuit Low Input |
DTC P0113 Intake Air Temperature Circuit High Input |

| DTC No. | Proceed to | DTC Detection Condition | Trouble Area |
| P0112 | Step 4 | Short in intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0113 | Step 2 | Open in intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or higher | Short circuit |
| Related DTCs | P0110: Intake air temperature sensor open/short (Fluctuating) P0112: Intake air temperature sensor short (Low electrical resistance) P0113: Intake air temperature sensor open (High electrical resistance) |
| Required Sensors/Components (Main) | Intake air temperature sensor |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 0.5 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs are not present | None |
| Intake air temperature sensor voltage | Less than 0.18 V |
| Intake air temperature sensor voltage | More than 4.91 V |
| Intake air temperature sensor voltage | 0.18 to 4.90 V [-40 to 140°C (-40 to 284°F)] |

| 1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the Techstream.
| Temperature Displayed | Proceed to |
| -40 °C (-40°F) | A |
| 140°C (284°F) or higher | B |
| Same as actual intake air temperature | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE USING TECHSTREAM (CHECK FOR OPEN IN WIRE HARNESS) |
![]() |
Disconnect the mass air flow meter connector.
Connect terminals THA and E2 of the mass air flow meter wire harness side connector.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the Techstream.
Reconnect the mass air flow meter connector.
|
| ||||
| OK | ||
| ||
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - HYBRID VEHICLE CONTROL ECU) |
![]() |
Disconnect the mass air flow meter connector.
Disconnect the hybrid vehicle control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B1-20 (THA) - B10-4 (THA) | Always | Below 1 Ω |
| B1-28 (E2) - B10-5 (E2) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| B1-20 (THA) or B10-4 (THA) - Body ground | Always | 10 kΩ or higher |
| B1-28 (E2) or B10-5 (E2) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the hybrid vehicle control ECU.
|
| ||||
| OK | ||
| ||
| 4.READ VALUE USING TECHSTREAM (CHECK FOR SHORT IN WIRE HARNESS) |
![]() |
Disconnect the mass air flow meter connector.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the Techstream.
Reconnect the mass air flow meter connector.
|
| ||||
| OK | ||
| ||
| 5.READ VALUE USING TECHSTREAM |
![]() |
Disconnect the mass air flow meter connector.
Disconnect the hybrid vehicle control ECU connector.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the Techstream.
Reconnect the mass air flow meter connector.
Reconnect the hybrid vehicle control ECU connector.
|
| ||||
| OK | ||
| ||