HYBRID CONTROL SYSTEM > TERMINALS OF ECU |

| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Standard Voltage (V) |
| D35-1 (BATT) - B3-5 (E1) | R - W-B | Constant power source | Always | 11 to 14 |
| D35-3 (TC) - B3-5 (E1) | L - W-B | Diagnostic terminal | Power switch on (IG) | 11 to 14 |
| D35-4 (PMET) - B3-5 (E1) | W - W-B | Power meter signal | Power switch on (IG) | Pulse generation (Waveform 1) |
| D35-8 (ABFS) - B3-5 (E1) | SB - W-B | Airbag activation signal | Power switch on (READY) (2 seconds after turning power switch on (ACC)) | Pulse generation (Waveform 2) |
| D35-9 (IGSW) - B3-5 (E1) | G - W-B | IG signal | Power switch on (IG) | 11 to 14 |
| D35-9 (IGSW) - B3-5 (E1) | G - W-B | IG signal | Power switch off to on (READY) | Pulse generation (Waveform 3) |
| D35-12 (RDY) - B3-5 (E1) | O - W-B | READY control signal | Power switch on (IG) Power switch off to on (READY) | Pulse generation (Waveform 4) |
| D35-17 (EVSW) - B3-5 (E1) | O - W-B | EV mode switch | Power switch on (IG), EV mode switch on | Below 1.5 |
| D35-17 (EVSW) - B3-5 (E1) | O - W-B | EV mode switch | Power switch on (IG), EV mode switch off | 11 to 14 |
| D35-20 (ST2) - B3-5 (E1) | Y - W-B | Starter signal | Power switch on (IG) | 0 to 1.5 |
| D35-23 (IWP) - B3-5 (E1) | V - W-B | HV water pump signal | Power switch on (READY) | 11 to 14 Pulse generation (Waveform 5) |
| D35-29 (NIWP) - B3-5 (E1) | P - W-B | HV water pump signal | Power switch on (READY) | Pulse generation (Waveform 5) |
| D35-24 (SPDI) - B3-5 (E1) | G - W-B | Vehicle speed signal | Approximately 12 mph (20 km/h) | Pulse generation (Waveform 6) |
| D35-25 (ST1-) - B3-5 (E1) | LG - W-B | Brake cancel switch | Power switch on (IG), brake pedal depressed | Below 0.5 |
| D35-25 (ST1-) - B3-5 (E1) | LG - W-B | Brake cancel switch | Power switch on (IG), brake pedal released | 11 to 14 |
| D35-22 (IMI) - B3-5 (E1) | L - W-B | Immobilizer communication | Immobilizer communicating | Pulse generation (Waveform 7) |
| D35-28 (IMO) - B3-5 (E1) | BR - W-B | Immobilizer communication | Immobilizer communicating | Pulse generation (Waveform 7) |
| D35-30 (THB) - B1-28 (E2) | V - BR | Auxiliary battery thermometer sensor signal | Auxiliary battery temperature 77°F (25°C) | 1.8 to 2.4 |
| D35-30 (THB) - B1-28 (E2) | V - BR | Auxiliary battery thermometer sensor signal | Auxiliary battery temperature 140°F (60°C) | 0.7 to 1.3 |
| D35-31 (STP) - B3-5 (E1) | R - W-B | Stop light switch | Brake pedal depressed | 11 to 14 |
| D35-31 (STP) - B3-5 (E1) | R - W-B | Stop light switch | Brake pedal released | Below 5 |
| D36-1 (CON3) - B3-5 (E1) | O - W-B | System main relay | Power switch off to on (READY) | Pulse generation (Waveform 3) |
| D36-2 (CON2) - B3-5 (E1) | GR - W-B | System main relay | Power switch off to on (READY) | Pulse generation (Waveform 3) |
| D36-3 (CON1) - B3-5 (E1) | LG - W-B | System main relay | Power switch off to on (READY) | Pulse generation (Waveform 3) |
| D36-4 (ILK) - B3-5 (E1) | W - W-B | Interlock switch | Power switch on (IG), inverter cover and service plug grip installed correctly | Below 1 |
| D36-4 (ILK) - B3-5 (E1) | W - W-B | Interlock switch | Power switch on (IG), inverter cover and service plug grip detached | 11 to 14 |
| D36-9 (SNWI) - B3-5 (E1) | SB - W-B | ECON mode switch | Power switch on (IG), ECON mode switch on | Below 1.5 |
| D36-9 (SNWI) - B3-5 (E1) | SB - W-B | ECON mode switch | Power switch on (IG), ECON mode switch off | 11 to 14 |
| D36-13 (SI2) - B3-5 (E1) | LG - W-B | HV battery blower fan | Power switch on (IG), during active test | Pulse generation (Waveform 8) |
| D36-14 (SI1) - B3-5 (E1) | O - W-B | HV battery blower fan | Power switch on (IG), during active test | Pulse generation (Waveform 8) |
| D36-15 (SI0) - B3-5 (E1) | P - W-B | HV battery blower fan | Power switch on (IG), during active test | Pulse generation (Waveform 8) |
| D36-19 (BTH+) - B3-5 (E1) | BR - W-B | Communication from battery to HV | Power switch on (IG) | Pulse generation (Waveform 9) |
| D36-30 (BTH-) - B3-5 (E1) | Y - W-B | Communication from battery to HV | Power switch on (IG) | Pulse generation (Waveform 9) |
| D36-21 (RMT) - D36-20 (RMTG) | GR - V | Rear motor temperature sensor | Refer to DATA LIST | - |
| D36-25 (CANH) - B3-5 (E1) | B - W-B | CAN communication system | Power switch on (IG) | Pulse generation (Waveform 10) |
| D36-33 (CANL) - B3-5 (E1) | W - W-B | CAN communication system | Power switch on (IG) | Pulse generation (Waveform 10) |
| A43-1 (+B2) - B3-5 (E1) | Y - W-B | Power source | Power switch on (IG) | 11 to 14 |
| A43-2 (+B1) - B3-5 (E1) | GR - W-B | Power source | Power switch on (IG) | 11 to 14 |
| A43-5 (OPM2) - B3-5 (E1) | P - W-B | Oil pump | Power switch on (READY) | 11 to 14 |
| A43-6 (OPM1) - B3-5 (E1) | R - W-B | Oil pump | Power switch on (READY) | Pulse generation (Waveform 11) |
| A43-7 (OPST) - B3-5 (E1) | L - W-B | Oil pump | Power switch on (READY) | Pulse generation (Waveform 11) |
| A43-9 (FCTL) - B3-5 (E1) | G - W-B | Cooling fan relay | Power switch on (IG) | 11 to 14 Pulse generation (Waveform 8) |
| A43-10 (RFC2) - B3-5 (E1) | BR - W-B | Radiator fan | Power switch on (READY), engine started | Pulse generation (Waveform 12) |
| A43-11 (NODD) - B3-5 (E1) | W - W-B | DC/DC operation monitor/stop request signal | Converter operating normally | 5 to 7 |
| A43-11 (NODD) - B3-5 (E1) | W - W-B | DC/DC operation monitor/stop request signal | Converter not operating normally | 2 to 4 |
| A43-11 (NODD) - B3-5 (E1) | W - W-B | DC/DC operation monitor/stop request signal | Converter ordered to stop | 0.1 to 0.4 |
| A43-12 (MREL) - B3-5 (E1) | Y - W-B | Main relay | Power switch on (IG) | 11 to 14 |
| A43-14 (RFC1) - B3-5 (E1) | V - W-B | Radiator fan | Power switch on (READY), engine started | Pulse generation (Waveform 12) |
| A43-15 (GO) - B3-5 (E1) | W - W-B | GO signal | Engine running | Pulse generation (Waveform 13) |
| B3-25 (NE+) - B3-24 (NE-) | R - G | Crankshaft position | Engine running | Pulse generation (Waveform 14) |
| A43-16 (NEO) - B3-5 (E1) | B - W-B | Engine speed signal | Engine running | Pulse generation (Waveform 15) |
| A43-18 (HTM+) - B3-5 (E1) | B - W-B | Communication from HV to MG | Power switch on (IG) | Pulse generation (Waveform 16) |
| A43-17 (HTM-) - B3-5 (E1) | W - W-B | Communication from HV to MG | Power switch on (IG) | Pulse generation (Waveform 16) |
| A43-21 (HSDN) - B3-5 (E1) | B - W-B | MG shutdown signal | Power switch on (READY) | Below 2 |
| A43-22 (CLK+) - B3-5 (E1) | B - W-B | MG communication clock signal | Power switch on (IG) | Pulse generation (Waveform 17) |
| A43-29 (CLK-) - B3-5 (E1) | W - W-B | MG communication clock signal | Power switch on (IG) | Pulse generation (Waveform 17) |
| A43-23 (REQ+) - B3-5 (E1) | B - W-B | MG communication request signal | Power switch on (IG) | Pulse generation (Waveform 18) |
| A43-30 (REQ-) - B3-5 (E1) | W - W-B | MG communication request signal | Power switch on (IG) | Pulse generation (Waveform 18) |
| A43-24 (VCP1) - A43-33 (EP1) | G - W | Accelerator pedal position sensor power source (for VPA1) | Power switch on (IG) | 4.5 to 5.5 |
| A43-25 (VPA) - A43-33 (EP1) | BR - W | Accelerator pedal position sensor (for accelerator pedal position detection) | Power switch on (IG), accelerator pedal released | 0.4 to 1.4 |
| A43-25 (VPA) - A43-33 (EP1) | BR - W | Accelerator pedal position sensor (for accelerator pedal position detection) | Power switch on (IG), engine stopped, shift lever in the P position, accelerator pedal fully depressed | 2.6 to 4.5 |
| A43-31 (VCP2) - A43-32 (EP2) | L - Y | Accelerator pedal position sensor power source (for VPA2) | Power switch on (IG) | 4.5 to 5.5 |
| A43-26 (VPA2) - A43-32 (EP2) | R - Y | Accelerator pedal position sensor (for sensor malfunction detection) | Power switch on (IG), accelerator pedal released | 1.0 to 2.2 |
| A43-26 (VPA2) - A43-32 (EP2) | R - Y | Accelerator pedal position sensor (for sensor malfunction detection) | Power switch on (IG), engine stopped, shift lever in the P position, accelerator pedal fully depressed | 3.4 to 5.3 |
| A43-28 (MTH+) - B3-5 (E1) | B - W-B | Communication from MG to HV | Power switch on (READY) | Pulse generation (Waveform 19) |
| A43-27 (MTH-) - B3-5 (E1) | W - W-B | Communication from MG to HV | Power switch on (READY) | Pulse generation (Waveform 19) |
| B3-12 (P) - B3-5 (E1) | L - W-B | Shift lever position sensor | Power switch on (IG), shift lever in the P position | 11 to 14 |
| B3-12 (P) - B3-5 (E1) | L - W-B | Shift lever position sensor | Power switch on (IG), shift lever not in the P position | 0 |
| B3-11 (R) - B3-5 (E1) | G - W-B | Shift lever position sensor | Power switch on (IG), shift lever in the R position | 11 to 14 |
| B3-11 (R) - B3-5 (E1) | G - W-B | Shift lever position sensor | Power switch on (IG), shift lever not in the R position | 0 |
| B3-10 (N) - B3-5 (E1) | B - W-B | Shift lever position sensor | Power switch on (IG), shift lever in the N position | 11 to 14 |
| B3-10 (N) - B3-5 (E1) | B - W-B | Shift lever position sensor | Power switch on (IG), shift lever not in the N position | 1 to 2.5 |
| B3-9 (D) - B3-5 (E1) | Y - W-B | Shift lever position sensor | Power switch on (IG), shift lever in the D position | 11 to 14 |
| B3-9 (D) - B3-5 (E1) | Y - W-B | Shift lever position sensor | Power switch on (IG), shift lever not in the D position | 0 |
| B3-8 (B) - B3-5 (E1) | BR - W-B | Shift lever position sensor | Power switch on (IG), shift lever in the B position | 11 to 14 |
| B3-8 (B) - B3-5 (E1) | BR - W-B | Shift lever position sensor | Power switch on (IG), shift lever not in the B position | 0 |
| B2-10 (MJ) - B3-5 (E1) | G - W-B | Shift lever position sensor | Power switch on (IG), shift lever in the P, R, N, D or B position | 11 to 14 |
| B2-11 (FD) - B3-5 (E1) | W - W-B | Shift lever position sensor | Power switch on (IG), shift lever in the D or B position | 11 to 14 |
| B2-11 (FD) - B3-5 (E1) | W - W-B | Shift lever position sensor | Power switch on (IG), shift lever not in the D or B position | 0 |
| B2-12 (RV) - B3-5 (E1) | B - W-B | Shift lever position sensor | Power switch on (IG), shift lever in the R position | 11 to 14 |
| B2-12 (RV) - B3-5 (E1) | B - W-B | Shift lever position sensor | Power switch on (IG), shift lever not in the R position | 0 |
| B2-14 (CLK) - B3-5 (E1) | G - W-B | A/C communication signal | Power switch on (READY) | Pulse generation (Waveform 20) |
| B2-15 (ITE) - B3-5 (E1) | P - W-B | A/C communication signal | Power switch on (READY) | Pulse generation (Waveform 20) |
| B2-16 (ETI ) - B3-5 (E1) | Y - W-B | A/C communication signal | Power switch on (READY) | Pulse generation (Waveform 20) |
| B2-18 (STB) - B3-5 (E1) | B - W-B | A/C communication signal | Power switch on (READY) | Pulse generation (Waveform 20) |
| A43-4 (WP) - B3-5 (E1) | V - W-B | A/C WP relay signal | Power switch on (READY) | Below 2 |
| B1-22 (GMT) - B1-32 (GMTG) | L - P | Generator temperature sensor | Refer to DATA LIST | - |
| B1-26 (MMT) - B1-33 (MMTG) | G - R | Motor temperature sensor | Refer to DATA LIST | - |
| B1-27 (AS1) - B1-34 (AS1G) | V - W | Circuit breaker sensor | Satellite signal system operating normally | 2.3 to 3.1 |
| Oscilloscope waveforms |
![]() |
Waveform 1 (power meter signal)
| Item | Contents |
| Terminal | PMET - E1 |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 2 (airbag activation signal)
| Item | Contents |
| Terminal | ABFS - E1 |
| Equipment Setting | 5 V/DIV., 500 ms./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 3 (system main relay operation signal)
| Item | Contents |
| Terminal | CH1: IGSW - E1 CH2: CON1 - E1 CH3: CON2 - E1 CH4: CON3 - E1 |
| Equipment Setting | 10 V/DIV., 500 ms./DIV. |
| Condition | Power switch off to on (READY) |
![]() |
Waveform 4 (READY control signal)
| Item | Contents |
| Terminal | RDY - E1 |
| Equipment Setting | 10 V/DIV., 10 ms./DIV. |
| Condition | Power switch on (IG) Power switch on (READY) |
![]() |
Waveform 5 (HV water pump signal)
| Item | Contents |
| Terminal | CH1: IWP - E1 CH2: NIWP - E1 |
| Equipment Setting | 5 V/DIV., 2 ms./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 6 (vehicle speed signal)
| Item | Contents |
| Terminal | SPDI - E1 |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Driving at approximately 12 mph (20 km/h) with power switch on (READY) |
![]() |
Waveform 7 (immobilizer communication signal)
| Item | Contents |
| Terminal | CH1: IMO - E1 CH2: IMI - E1 |
| Equipment Setting | 5 V/DIV., 200 ms./DIV. |
| Condition | Power switch off → Power switch on (IG) → Power switch on (READY) |
![]() |
Waveform 8 (HV battery blower fan operation signal)
| Item | Contents |
| Terminal | CH1: SI0 - E1 CH2: SI1 - E1 CH3: SI2 - E1 CH4: FCTL - E1 |
| Equipment Setting | 10 V/DIV., 200 ms./DIV. |
| Condition | Power switch on (IG), during active test |
![]() |
Waveform 9 (communication signal from battery smart unit to hybrid vehicle control ECU)
| Item | Contents |
| Terminal | CH1: BTH+ - E1 CH2: BTH- - E1 |
| Equipment Setting | 2 V/DIV., 500 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 10 (CAN communication signal)
| Item | Contents |
| Terminal | CH1: CANH - E1 CH2: CANL - E1 |
| Equipment Setting | 1 V/DIV., 20 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 11 (oil pump signal)
| Item | Contents |
| Terminal | CH1: OPM1 - E1 CH2: OPST - E1 |
| Equipment Setting | 5 V/DIV., 5 ms./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 12 (radiator fan operation signal)
| Item | Contents |
| Terminal | CH1: RFC1 - E1 CH2: RFC2 - E1 |
| Equipment Setting | 5 V/DIV., 1 ms./DIV. |
| Condition | Power switch on (READY) with engine running |
![]() |
Waveform 13 (GO signal)
| Item | Contents |
| Terminal | GO - E1 |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Power switch on (READY) with engine running |
![]() |
Waveform 14 (crankshaft position signal)
| Item | Contents |
| Terminal | NE+ - NE- |
| Equipment Setting | 5 V/DIV., 1 ms./DIV. |
| Condition | Power switch on (READY) with engine running |
![]() |
Waveform 15 (engine speed signal)
| Item | Contents |
| Terminal | NEO - E1 |
| Equipment Setting | 10 V/DIV., 10 ms./DIV. |
| Condition | Power switch on (READY) with engine running |
![]() |
Waveform 16 (communication signal from hybrid vehicle control ECU to MG ECU)
| Item | Contents |
| Terminal | CH1: HTM+ - E1 CH2: HTM- - E1 |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 17 (MG ECU communication clock signal)
| Item | Contents |
| Terminal | CH1: CLK+ - E1 CH2: CLK- - E1 |
| Equipment Setting | 1 V/DIV., 1 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 18 (MG ECU communication request signal)
| Item | Contents |
| Terminal | CH1: REQ+ - E1 CH2: REQ- - E1 |
| Equipment Setting | 1 V/DIV., 1 ms./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 19 (communication signal from MG ECU to hybrid vehicle control ECU)
| Item | Contents |
| Terminal | CH1: MTH+ - E1 CH2: MTH- - E1 |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Power switch on (READY) |
![]() |
Waveform 20 (A/C communication signal)
| Item | Contents |
| Terminal | CH1: CLK - E1 CH2: ITE - E1 CH3: ETI - E1 CH4: STB - E1 |
| Equipment Setting | 10 V/DIV., 100 ms./DIV. |
| Condition | Power switch on (READY) with A/C stopped |

| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Standard voltage (V) |
| C-1 (RVSPI) - C-18 (RSG) | - | Power source for rear current sensor | Power switch on (IG) | 14.25 to 15.75 |
| C-2 (RVSPO) - C-18 (RSG) | - | Power source for rear current sensor | Power switch on (IG) | 14.25 to 15.75 |
| C-6 (RVSNO) - C-18 (RSG) | - | Power source for rear current sensor | Power switch on (IG) | -15.9 to -14.1 |
| C-7 (RVSNI) - C-18 (RSG) | - | Power source for rear current sensor | Power switch on (IG) | -15.9 to -14.1 |
| C-8 (RIT) - C-19 (RIVG) | - | Rear motor inverter temperature | Power switch on (IG) | 1.5 to 4.5 |
| C-9 (RFIV) - C-19 (RIVG) | - | Rear motor inverter fail signal | Power switch on (IG), inverter operating normally | 5.5 to 7.5 |
| C-9 (RFIV) - C-19 (RIVG) | - | Rear motor inverter fail signal | Power switch on (IG), inverter not operating normally | 2 to 3 |
| C-10 (RIVA) - C-18 (RSG) | - | Rear motor V phase current | Power switch on (IG) | Approximately 0 |
| C-12 (RIVB) - C-18 (RSG) | - | Rear motor V phase current | Power switch on (IG) | Approximately 0 |
| C-11 (RIWA) - C-18 (RSG) | - | Rear motor W phase current | Power switch on (IG) | Approximately 0 |
| C-13 (RIWB) - C-18 (RSG) | - | Rear motor W phase current | Power switch on (IG) | Approximately 0 |
| C-14 (RSDN) - C-19 (RIVG) | - | Rear motor shutdown signal | Power switch on (IG), shift lever in the N position | 0.2 to 0.7 |
| C-14 (RSDN) - C-19 (RIVG) | - | Rear motor shutdown signal | Power switch on (IG), shift lever in the P position | 5.1 to 13.6 |
| C-15 (RUU) - C-19 (RIVG) | - | Rear motor switch U signal | Power switch on (IG) | Pulse generation (Waveform 1) |
| C-16 (RWU) - C-19 (RIVG) | - | Rear motor switch W signal | Power switch on (IG) | Pulse generation (Waveform 2) |
| C-17 (RVU) - C-19 (RIVG) | - | Rear motor switch V signal | Power switch on (IG) | Pulse generation (Waveform 3) |
| B-33 (OVLMO) - A-18 (GCNV) | - | Boost converter overvoltage signal | Power switch on (IG), boost converter operating normally | 5.3 to 7.7 |
| B-33 (OVLMO) - A-18 (GCNV) | - | Boost converter overvoltage signal | Power switch on (IG), boost converter not operating normally | 1.9 to 3.0 |
| C-29 (OVHRO) - B-17 (GINV) | - | Motor inverter overvoltage signal | Power switch on (IG), inverter operating normally | 5.5 to 7.5 |
| C-29 (OVHRO) - B-17 (GINV) | - | Motor inverter overvoltage signal | Power switch on (IG), inverter not operating normally | 2 to 3 |
| C-31 (+BRr) - C-26 (GNDRr) | - | Power source for rear inverter | Power switch on (IG) | 11 to 14 |
| B-7 (MIT) - B-17 (GINV) | - | Motor inverter temperature | Power switch on (IG) | 1.5 to 4.5 |
| B-8 (MFIV) - B-17 (GINV) | - | Motor inverter fail signal | Power switch on (IG), inverter operating normally | 5.5 to 7.5 |
| B-8 (MFIV) - B-17 (GINV) | - | Motor inverter fail signal | Power switch on (IG), inverter not operating normally | 2 to 3 |
| B-9 (MIVA) - B-17 (GINV) | - | Motor V phase current | Power switch on (IG) | Approximately 0 |
| B-11 (MIVB) - B-17 (GINV) | - | Motor V phase current | Power switch on (IG) | Approximately 0 |
| B-10 (MIWA) - B-17 (GINV) | - | Motor W phase current | Power switch on (IG) | Approximately 0 |
| B-12 (MIWB) - B-17 (GINV) | - | Motor W phase current | Power switch on (IG) | Approximately 0 |
| B-13 (MSDN) - B-17 (GINV) | - | Motor shutdown signal | Power switch on (IG), shift lever in the N position | 0.2 to 0.7 |
| B-13 (MSDN) - B-17 (GINV) | - | Motor shutdown signal | Power switch on (IG), shift lever in the P position | 5.1 to 13.6 |
| B-14 (GUU) - B-17 (GINV) | - | Generator switch U signal | Power switch on (IG) | Pulse generation (Waveform 4) |
| B-15 (GWU) - B-17 (GINV) | - | Generator switch W signal | Power switch on (IG) | Pulse generation (Waveform 5) |
| B-16 (GVU) - B-17 (GINV) | - | Generator switch V signal | Power switch on (IG) | Pulse generation (Waveform 6) |
| B-18 (GIT) - B-17 (GINV) | - | Generator temperature sensor | Power switch on (IG) | 1.5 to 4.5 |
| B-19 (GFIV) - B-17 (GINV) | - | Generator fail signal | Power switch on (IG), inverter operating normally | 5.5 to 7.5 |
| B-19 (GFIV) - B-17 (GINV) | - | Generator fail signal | Power switch on (IG), inverter not operating normally | 2 to 3 |
| B-20 (GIVA) - B-17 (GINV) | - | Generator V phase current | Power switch on (IG) | Approximately 0 |
| B-22 (GIVB) - B-17 (GINV) | - | Generator V phase current | Power switch on (IG) | Approximately 0 |
| B-21 (GIWA) - B-17 (GINV) | - | Generator W phase current | Power switch on (IG) | Approximately 0 |
| B-23 (GIWB) - B-17 (GINV) | - | Generator W phase current | Power switch on (IG) | Approximately 0 |
| B-24 (GSDN) - B-17 (GINV) | - | Generator shutdown signal | Power switch on (IG), shift lever in the N position | 0.2 to 0.7 |
| B-24 (GSDN) - B-17 (GINV) | - | Generator shutdown signal | Power switch on (IG), shift lever in the P position | 5.1 to 13.6 |
| B-25 (MUU) - B-17 (GINV) | - | Motor switch U signal | Power switch on (IG) | Pulse generation (Waveform 7) |
| B-26 (MWU) - B-17 (GINV) | - | Motor switch W signal | Power switch on (IG) | Pulse generation (Waveform 8) |
| B-27 (MVU) - B-17 (GINV) | - | Motor switch V signal | Power switch on (IG) | Pulse generation (Waveform 9) |
| B-31 (VH) - B-17 (GINV) | - | Inverter capacitor voltage monitor | Power switch on (READY) | 1.6 to 3.8 |
| B-32 (OVHI) - B-17 (GINV) | - | Motor inverter overvoltage signal | Power switch on (IG), inverter operating normally | 5.5 to 7.5 |
| B-32 (OVHI) - B-17 (GINV) | - | Motor inverter overvoltage signal | Power switch on (IG), inverter not operating normally | 2 to -3 |
| B-35 (+BMG) - B-28 (GNDMG) | - | Power source for main inverter | Power switch on (IG) | 11 to 14 |
| A-10 (CPWM) - A-18 (GCNV) | - | Boost converter PWM switch signal | Power switch on (READY), parking brake on, shift lever in the D position, brake and accelerator pedals depressed | Pulse generation* |
| A-11 (CSDN) - A-18 (GCNV) | - | Boost converter shutdown signal | Power switch on (IG) | 5.6 or higher |
| A-12 (VL) - A-18 (GCNV) | - | Boost converter input voltage | Power switch on (READY) | 2.6 to 4.3 |
| A-13 (OVL) - A-18 (GCNV) | - | Boost converter overvoltage signal | Power switch on (IG), boost converter operating normally | 5.3 to 7.7 |
| A-13 (OVL) - A-18 (GCNV) | - | Boost converter overvoltage signal | Power switch on (IG), boost converter not operating normally | 1.9 to 3.0 |
| A-14 (FCV) - A-18 (GCNV) | - | Boost converter fail signal | Power switch on (IG), boost converter operating normally | 5.3 to 7.7 |
| A-14 (FCV) - A-18 (GCNV) | - | Boost converter fail signal | Power switch on (IG), boost converter not operating normally | 1.9 to 3.0 |
| A-15 (IDH) - A-1 (GND1) | - | Blower motor for A/C operation inhibition request signal | Power switch on (IG), permission for blower motor operation requested | 5 to 7 |
| A-15 (IDH) - A-1 (GND1) | - | Blower motor for A/C operation inhibition request signal | Power switch on (IG), blower motor operation inhibition requested | 2 to 4 |
| A-16 (VLO) - A-1 (GND1) | - | DC/DC converter voltage switch signal | Power switch on (IG) | Pulse generation (Waveform 10) |
| A-17 (SO) - A-1 (GND1) | - | Auxiliary battery voltage monitor | Power switch on (IG) | 11 to 14 |
| A-19 (CT) - A-18 (GCNV) | - | Boost converter temperature sensor | Power switch on (IG) | 1.5 to 4.5 |
| A-21 (HWT) - A-20 (HWTG) | - | Inverter coolant temperature sensor | Power switch on (IG) | 0.5 to 4.8 |
| A-26 (NODDI) - A-1 (GND1) | - | DC/DC converter operation monitor/stop request signal | DC/DC converter operating normally | 5.3 to 6.7 |
| A-26 (NODDI) - A-1 (GND1) | - | DC/DC converter operation monitor/stop request signal | DC/DC converter not operating normally | 2.5 to 3.5 |
| A-26 (NODDI) - A-1 (GND1) | - | DC/DC converter operation monitor/stop request signal | DC/DC converter ordered to stop | 0.1 to 0.8 |
| A-30 (OVHCO) - A-18 (GCNV) | - | Motor inverter overvoltage signal | Power switch on (IG), inverter operating normally | 5.5 to 7.5 |
| A-30 (OVHCO) - A-18 (GCNV) | - | Motor inverter overvoltage signal | Power switch on (IG), inverter not operating normally | 2 to 3 |
| A-32 (+BC) - A-28 (GNDC) | - | Power source for boost converter | Power switch on (IG) | 11 to 14 |
| A42-4 (+B2) - A-1 (GND1) | LG | MG ECU power source | Power switch on (IG) | 11 to 14 |
| A42-7 (+B) - A-1 (GND1) | P | MG ECU power source | Power switch on (IG) | 11 to 14 |
| A42-9 (MTH+) - A-1 (GND1) | B | Communication signal from MG to HV | Power switch on (IG) | Pulse generation (Waveform 11) |
| A42-10 (MTH-) - A-1 (GND1) | W | Communication signal from MG to HV | Power switch on (IG) | Pulse generation (Waveform 11) |
| A42-12 (HTM+) - A-1 (GND1) | B | Communication signal from HV to MG | Power switch on (IG) | Pulse generation (Waveform 12) |
| A42-13 (HTM-) - A-1 (GND1) | W | Communication signal from HV to MG | Power switch on (IG) | Pulse generation (Waveform 12) |
| A42-14 (NE) - A-1 (GND1) | B | Engine speed signal | Power switch on (READY) with engine running | Pulse generation* |
| A42-15 (REQ+) - A-1 (GND1) | B | Communication request signal | Power switch on (IG) | Pulse generation (Waveform 13) |
| A42-16 (REQ-) - A-1 (GND1) | W | Communication request signal | Power switch on (IG) | Pulse generation (Waveform 13) |
| A42-17 (CLK+) - A-1 (GND1) | B | Communication clock signal | Power switch on (IG) | Pulse generation (Waveform 14) |
| A42-18 (CLK-) - A-1 (GND1) | W | Communication clock signal | Power switch on (IG) | Pulse generation (Waveform 14) |
| A42-21 (RRF) - A42-22 (RRFG) | BR - G | Rear motor resolver signal | Rear motor resolver stopped or running | Pulse generation (Waveform 15) |
| A42-29 (RSN) - A42-30 (RSNG) | L - R | Rear motor resolver signal | Rear motor resolver stopped or running | Pulse generation (Waveform 15) |
| A42-11 (RCS) - A42-23 (RCSG) | W - Y | Rear motor resolver signal | Rear motor resolver stopped or running | Pulse generation (Waveform 15) |
| A42-24 (GI) - A-1 (GND1) | W | GI signal | Power switch on (READY) with engine running | Pulse generation* |
| A42-26 (HSDN) - B-17 (GINV) | B | Emergency shutdown signal | Power switch on (IG) | Below 0.5 |
| A42-33 (NODD) - A-1 (GND1) | W | DC/DC converter operation monitor/stop request signal | DC/DC converter operating normally | 5.3 to 6.7 |
| A42-33 (NODD) - A-1 (GND1) | W | DC/DC converter operation monitor/stop request signal | DC/DC converter not operating normally | 2.5 to 3.5 |
| A42-33 (NODD) - A-1 (GND1) | W | DC/DC converter operation monitor/stop request signal | DC/DC converter ordered to stop | 0.1 to 0.8 |
| A42-35 (SI) - A-1 (GND1) | LG | Auxiliary battery voltage monitor | Power switch on (IG) | 11 to 14 |
| B49-12 (GRF) - B49-22 (GRFG) | BR - G | Generator resolver signal | Generator resolver stopped or running | Pulse generation (Waveform 16) |
| B49-11 (GSN) - B49-10 (GSNG) | L - R | Generator resolver signal | Generator resolver stopped or running | Pulse generation (Waveform 16) |
| B49-9 (GCS) - B49-8 (GCSG) | W - Y | Generator resolver signal | Generator resolver stopped or running | Pulse generation (Waveform 16) |
| B49-13 (MRF) - B49-23 (MRFG) | BR - G | Motor resolver signal | Motor resolver stopped or running | Pulse generation (Waveform 17) |
| B49-21 (MSN) - B49-20 (MSNG) | L - R | Motor resolver signal | Motor resolver stopped or running | Pulse generation (Waveform 17) |
| B49-19 (MCS) - B49-18 (MCSG) | W - Y | Motor resolver signal | Motor resolver stopped or running | Pulse generation (Waveform 17) |
| Oscilloscope waveforms |
![]() |
Waveform 1 (rear motor switch U signal)
| Item | Contents |
| Terminal | RUU - RIVG |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 2 (rear motor switch W signal)
| Item | Contents |
| Terminal | RWU - RIVG |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 3 (rear motor switch V signal)
| Item | Contents |
| Terminal | RVU - RIVG |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 4 (generator switch U signal)
| Item | Contents |
| Terminal | GUU - GINV |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 5 (generator switch W signal)
| Item | Contents |
| Terminal | GWU - GINV |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 6 (generator switch V signal)
| Item | Contents |
| Terminal | GVU - GINV |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 7 (motor switch U signal)
| Item | Contents |
| Terminal | MUU - GINV |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 8 (motor switch W signal)
| Item | Contents |
| Terminal | MWU - GINV |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 9 (motor switch V signal)
| Item | Contents |
| Terminal | MVU - GINV |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 10 (DC/DC converter voltage switch signal)
| Item | Contents |
| Terminal | VLO - GND1 |
| Equipment Setting | 5 V/DIV., 100 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 11 (communication signal from MG ECU to hybrid vehicle control ECU)
| Item | Contents |
| Terminal | CH1: MTH+ - GND1 CH2: MTH- - GND1 |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 12 (communication signal from hybrid vehicle control ECU to MG ECU)
| Item | Contents |
| Terminal | CH1: HTM+ - GND1 CH2: HTM- - GND1 |
| Equipment Setting | 1 V/DIV., 200 ms./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 13 (MG ECU communication request signal)
| Item | Contents |
| Terminal | CH1: REQ+ - GND1 CH2: REQ- - GND1 |
| Equipment Setting | 1 V/DIV., 1 ms./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 14 (MG ECU communication clock signal)
| Item | Contents |
| Terminal | CH1: CLK+ - GND1 CH2: CLK- - GND1 |
| Equipment Setting | 1 V/DIV., 1 μs./DIV. |
| Condition | Power switch on (IG) |
![]() |
Waveform 15 (rear motor resolver signal)
| Item | Contents |
| Terminal | CH1: RRF - RRFG CH2: RSN - RSNG CH2: RCS - RCSG |
| Equipment Setting | CH1: 10 V/DIV., 1 ms./DIV. CH2, CH3: 5 V/DIV., 1 ms./DIV. |
| Condition | Resolver running |
![]() |
Waveform 16 (generator resolver signal)
| Item | Contents |
| Terminal | CH1: GRF - GRFG CH2: GSN - GSNG CH2: GCS - GCSG |
| Equipment Setting | CH1: 10 V/DIV., 1 ms./DIV. CH2, CH3: 5 V/DIV., 1 ms./DIV. |
| Condition | Resolver running |
![]() |
Waveform 17 (motor resolver signal)
| Item | Contents |
| Terminal | CH1: MRF - MRFG CH2: MSN - MSNG CH2: MCS - MCSG |
| Equipment Setting | CH1: 10 V/DIV., 1 ms./DIV. CH2, CH3: 5 V/DIV., 1 ms./DIV. |
| Condition | Resolver running |