HYBRID CONTROL SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Data List.
Check the results by referring to the following table.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Engine Coolant Temp | Engine coolant temperature/Min.: -40°F (-40°C), Max.: 284°F (140°C) | After warming up: 176 to 212°F (80 to 100°C) | - |
| Engine Revolution | Engine speed/Min.: 0 rpm, Max.: 16383.75 rpm | Idling (INSPECTION MODE, P position, A/C OFF): 850 to 950 rpm | - |
| Vehicle Spd | Vehicle speed/Min.: 0 MPH (0 km/h), Max.: 158 MPH (255 km/h) | Vehicle stopped: 0 MPH (0 km/h) | - |
| Engine Run Time | Elapsed time after starting engine/Min.: 0 s, Max.: 65,535 s | - | - |
| +B | Auxiliary battery voltage/Min.: 0 V, Max.: 65.535 V | Constant: Auxiliary battery voltage +/-3 V | - |
| Accel Pedal Pos #1 | Accelerator pedal position sensor No. 1/Min.: 0%, Max.: 100% | Accelerator pedal depressed: Changes with accelerator pedal pressure | - |
| Accel Pedal Pos #2 | Accelerator pedal position sensor No. 2/Min.: 0%, Max.: 100% | Accelerator pedal depressed: Changes with accelerator pedal pressure | - |
| Ambient Temperature | Ambient air temperature/Min.: -40°F (-40°C), Max.: 419°F (215°C) | Power switch on (IG): Same as ambient air temperature | - |
| Intake Air Temperature | Intake air temperature/Min.: -40°F (-40°C), Max.: 284°F (140°C) | Constant: Same as ambient air temperature | - |
| DTC Clear Warm Up | The number of times the engine is warmed up after clearing DTCs/Min.: 0, Max.: 255 | MIL OFF, engine coolant temperature increases from below 72°F (22°C) before starting the engine to above 158°F (70°C) after starting the engine: Increases once | - |
| DTC Clear Run Distance | Drive distance after clearing DTCs/Min.: 0 mile (0 km), Max.: 40,723 mile (65,535 km) | - | - |
| DTC Clear Min | Elapsed time after clearing DTCs/Min.: 0 Min, Max.: 65,535 Min | - | - |
| MIL on Run Distance | MIL ON run distance/Min.: 0 mile (0 km), Max.: 40,723 mile (65,535 km) | Distance after DTC detected | - |
| MIL on Engine Run Time | MIL ON engine run time/ Min.: 0 Min Max.: 65.535 Min | Time after DTC detected | - |
| MIL Status | MIL status/ON or OFF | MIL ON: ON | Constant ON: Repair in accordance with detected DTCs |
| Model Code | Model code | - | Identifying model code: MHU48 |
| Engine Code | Engine code | - | Identifying engine type: 3MZFE |
| ECU Code | ECU code | 48320 | - |
| Destination | Destination | - | Identifying destination: A (USA) |
| Motor(MG2) Revolution | MG2 revolution/Min.: -16,383 rpm, Max.: 16,383 rpm | - | - |
| Motor(MG2) Torq | MG2 torque/Min.: -500 N*m, Max.: 500 N*m | - | - |
| Rear Motor Revolution | MGR revolution/Min.: -16,383 rpm, Max.: 16,383 rpm | - | - |
| Rear Motor Torq | MGR torque/Min.: -500 N*m, Max.: 500 N*m | - | - |
| M(MG2) Trq Exec Val | MG2 torque execution value/Min.: -512 Nm, Max.: 508 Nm | After full-load acceleration with READY light ON and engine stopped: Less than +-20% of Motor (MG2) Torq | - |
| Rear Mtr Trq Exec Val | MGR torque execution value/Min.: -512 Nm, Max.: 508 Nm | After full-load acceleration with READY light ON and engine stopped: Less than +-20% of Rear Motor Torq | - |
| Generator(MG1) Rev | MG1 revolution/Min.: -16,383 rpm, Max.: 16,383 rpm | - | - |
| Generator(MG1) Torq | MG1 torque/Min.: -500 N*m, Max.: 500 N*m | - | - |
| G(MG1) Trq Exec Val | MG1 torque execution value/Min.: -512 Nm, Max.: 508 Nm | After full-load acceleration with READY light ON and engine stopped: Less than +-20% of Generator (MG1) Torq | - |
| Regenerative Brake Torq | Regenerative braking execution torque/Min.: 0 N*m, Max.: 1,020 N*m | - | - |
| Rqst Regen Brake Torq | Regenerative braking request torque/Min.: 0 N*m, Max.: 1,020 N*m | Vehicle speed 19 MPH (30 km/h) and master cylinder hydraulic pressure -200 N*m: Changes with brake pedal pressure | - |
| Rear Regen Brake Torq | Regenerative braking execution torque/Min.: 0 N*m, Max.: 1,020 N*m | - | - |
| R Rqst Regen Brk Torq | Regenerative braking execution torque/Min.: 0 N*m, Max.: 1,020 N*m | Vehicle speed 19 MPH (30 km/h) and master cylinder hydraulic pressure -200 N*m: Changes with brake pedal pressure | - |
| Inverter Temp-(MG1) | Generator inverter temperature/Min.: -58°F (-50°C), Max.: 401°F (205°C) |
|
|
| Inverter Temp-(MG2) | Motor inverter temperature/Min.: -58°F (-50°C), Max.: 401°F (205°C) |
|
|
| Rear Inverter Temp | Rear motor inverter temperature/Min.: -58°F (-50°C), Max.: 401°F (205°C) |
|
|
| Motor Temp No2 | MG2 temperature/Min.: -58°F (-50°C), Max.: 401°F (205°C) |
|
|
| Motor Temp No1 | MG1 temperature/Min.: -58°F (-50°C), Max.: 401°F (205°C) |
|
|
| Rear Motor Temp | MGR temperature/Min.: -58°F (-50°C), Max.: 401°F (205°C) |
|
|
| Rear Torque Ratio | Rear Torque Ratio/Min.: 0%, Max.: 100% | - | - |
| Converter Temperature | Boost converter temperature/Min.: -58°F (-50°C), Max.: 401°F (205°C) |
|
|
| Accelerator Degree | Accelerator pedal depressed angle/Min.: 0%, Max.: 100% | Accelerator pedal depressed: Changes with accelerator pedal pressure | - |
| Request Power | Request engine power/Min.: 0 W, Max.: 320000 W | - | - |
| Target Engine Rev | Target engine speed/Min.: 0 rpm, Max.: 8,000 rpm | - | - |
| Engine Spd | Engine speed/Min.: 0 rpm, Max.: 8,000 rpm | Idling (INSPECTION MODE, P position, A/C OFF): 850 to 950 rpm | - |
| Vehicle Speed (Resolver) | Resolver/Min.: -159 MPH (-256 km/h), Max.: 158 MPH (254 km/h) | Same as vehicle speed | - |
| Master Cylinder Ctrl Trq | Braking torque that is equivalent to master cylinder hydraulic pressure/Min.: -2,040 N*m, Max.: 0 N*m | Brake pedal depressed: Changes with brake pedal pressure | - |
| State of Charge | Battery state of charge/Min.: 0%, Max.: 100% | Constant: 0 to 100% | - |
| WOUT Control Power | Discharge control power value/Min.: 0 W, Max.: 81,600 W | 36,000 W or less | - |
| WIN Control Power | Charge control power value/Min.: -40,800 W, Max.: 0 W | -36,000 W or more | - |
| Discharge Rqst to SOC | Discharge request to adjust SOC/Min.: -20,480 W, Max.: 20,320 W |
| - |
| Power Resource VB | HV battery voltage/Min.: 0 V, Max.: 510 V | READY light ON and P position: 240 to 400 V | - |
| Power Resource IB | HV battery current/Min.: -256 A, Max.: 254 A | - | - |
| VL-Voltage before boosting | High voltage before it is boosted/Min.: 0 V, Max.: 510 V | READY ON: Almost the same as the HV battery voltage |
|
| VH-Voltage after boosting | High voltage after it is boosted/Min.: 0 V, Max.: 765 V | Engine revving up in the P position: Between HV battery voltage and 650 V |
|
| Boost Ratio | Boost ratio/Min.: 0%, Max.: 100% | The pre-boost and the post boost voltages are equal: 0 to 10% | - |
| Drive Condition ID | Drive condition ID/Min.: 0, Max.: 6 |
| - |
| Shift Sensor Shift Pos | Shift lever position | P, R, N, D or B | - |
| Crank Position | Crankshaft position/Min.: -90 deg., Max.: 90 deg. | - | - |
| A/C Consumption Pwr | A/C consumption power/Min.: 0 kW, Max.: 5 kW | - | - |
| Loading Condition | Driving condition |
| - |
| Driving Pattern 1 to 3 | Driving pattern/ Lo Spd, MID Spd, or MID HI | - | - |
| Short Wave Highest Val | Waveform voltage in leak detection circuit/Min.: 0 V, Max.: 5 V | Left for 2 Minutes with power switch on (READY), and pre-boost and post-boost voltages are equal: 4 V or more | - |
| MG1 Control Mode | MG1 control mode | - | - |
| MG1 Carrier Frequency | MG1 carrier frequency/10 kHz / 5 kHz | - | - |
| MG2 Control Mode | MG2 control mode | - | - |
| MG2 Carrier Frequency | MG2 carrier frequency/5 kHz / 2.5 kHz / 1.25 kHz | - | - |
| Type of ECU | Type of ECU | - | Identifying ECU type: HV ECU |
| Num of Current Code | The number of current DTCs/Min.: 0, Max.: 255 | - | - |
| Num of History Code | The number of history DTCs/Min.: 0, Max.: 255 | - | - |
| Check Mode | Check mode/ ON or OFF | Check mode ON | |
| Rmg Control Mode | MGR control mode | - | - |
| Rmg Carrier Frequency | MGR carrier frequency/5 kHz / 2.5 kHz / 1.25 kHz | - | - |
| Shift Sensor SW - P | Shift lever position sensor/ON or OFF | P position: ON Except P position: OFF | - |
| Shift Sensor SW - R | Shift lever position sensor/ON or OFF | R position: ON Except R position: OFF | - |
| Shift Sensor SW - N | Shift lever position sensor/ON or OFF | N position: ON Except N position: OFF | - |
| Shift Sensor SW - D | Shift lever position sensor/ON or OFF | D position: ON Except D position: OFF | - |
| Shift Sensor SW - B | Shift lever position sensor/ON or OFF | B position: ON Except B position: OFF | - |
| Shift Sensor SW - FD | Shift lever position sensor/ON or OFF | D or B position: ON Except D or B position: OFF | - |
| Shift Sensor SW - RV | Shift lever position sensor/ON or OFF | R position: ON Except R position: OFF | - |
| Shift Sensor SW - MJ | Shift lever position sensor/ON or OFF | P, R, N, D or B position: ON | - |
| Calculate Load | Calculate load/Min.: 0%, Max.: 100% |
| - |
| Throttle Position | Throttle position sensor/Min.: 0%, Max.: 100% | Throttle valve fully closed: 10 to 24% Throttle valve fully open: 64 to 96% | - |
| L-Tmp Start Judging | Time of low temperature start judging/Min.: 0, Max.: 65535 | - | - |
| L-Tmp Start Accumulate | Low temperature starting accumulation time/Min.: 0, Max.: 67107840 | - | - |
| Engine Stop Request | Engine stop request/NO or RQST | Requesting engine stop: RQST | - |
| Engine Idling Request | Engine idling request/NO or RQST | Requesting idle: RQST | - |
| Main Batt Charging Rqst | HV battery charging request/NO or RQST | Requesting HV battery charging: RQST | - |
| HCAC OBD Request | HCAC OBD Request / NO or RQST | Requesting HCAC OBD: RQST | - |
| Aircon Request | Engine starting request from A/C amplifier/NO or RQST | Requesting engine start from A/C amplifier: RQST | - |
| Engine Warming Up Rqst | Engine warm-up request/NO or RQST | Requesting engine warm-up: RQST | - |
| System Precharge Relay Status - (SMRP) | Operating condition of SMR1/ON or OFF | Power switch on (READY): OFF | - |
| System Main Relay Status - SMRB | Operating condition of SMR2/ON or OFF | Power switch on (READY): ON | - |
| System Main Relay Status - SMRG | Operating condition of SMR3/ON or OFF | Power switch on (READY): ON | - |
| MG1 Gate Status | MG1 gate status/ON or OFF | Shutting down generator inverter: ON | - |
| MG2 Gate Status | MG2 gate status/ON or OFF | Shutting down motor inverter: ON | - |
| Converter Gate Status | Boost converter gate status/ON or OFF | Shutting down boost converter: ON | - |
| Aircon Gate Status | A/C gate status: ON or OFF | Shutting down A/C inverter: ON | - |
| Shutdown (Rear) | MGR gate status/ON or OFF | Shutting down rear motor inverter: ON | - |
| Converter Carrier Freq | Converter Carrier Frequency/10 kHz / 5 kHz | - | - |
| Complete Parts Monitor | Complete Parts Monitor/ Not Avl or Avail | - | - |
| Component Monitor ENA | Comprehensive Component Monitor ENA/ Unable or Enable | - | - |
| Component Monitor CMPL | Comprehensive Component Monitor CMPL/ Compl or Incmpl | - | - |
| Battery State of Charge | Battery state of charge/Min.: 0%, Max.: 100% | - | - |
| Delta SOC | Difference between maximum and Minimum values of SOC/Min.: 0%, Max.: 100% | READY light ON, engine stopped and no electrical load: 0 to 60% | - |
| Batt Pack Current Val | Current value of battery pack/Min.: -327.68 A, Max.: 327.67 A | -Immediately after a full-load acceleration with the engine stopped: Maximum 190 A (room temperature) -Shifting into N position 1 second after engine automatically started in the P position with engine stopped, headlights ON, A/C fan speed high, and READY light ON: Maximum 30 A | - |
| VMF Fan Motor Voltage1 to 3 | Battery blower motor monitoring voltage/Min.: 0 V, Max.: 25.4 V | Fan mode 1 with READY light ON and P position: 2.0 to 2.6 V | - |
| Auxiliary Battery Vol | Auxiliary battery voltage/ Min.: 0 V, Max.: 25.4 V | Equivalent to auxiliary battery voltage | - |
| Charge Control Value | Charge control wattage/ Min.: -64 kW, Max.: 63.5 kW | -33 kW or more | - |
| Discharge Control Value | Discharge control wattage/Min.: -64 kW, Max.: 63.5 kW | 36 kW or less | - |
| Cooling Fan Mode1 to 3 | Battery blower motor actuation mode/Min.: 0, Max.: 6 | Stopped: 0 Low to high speed actuation: 1 to 6 | - |
| ECU Control Mode | ECU control mode/Min.: 0, Max.: 4 | - | - |
| Standby Blower Request | Battery blower motor stop control request (standby blower)/ON or OFF | ON/OFF | - |
| Temp of Batt TB 1 to 8 | Temperature of HV battery/Min.: -557.824°F (-327.68°C), Max.: 621.806°F (327.67°C) | Undisturbed for 1 day: Same as ambient air temperature | - |
| Battery Block Num | The number of battery blocks/Min.: 0, Max.: 255 | Always: 15 | - |
| Batt Block Minimum Vol | Battery block Minimum voltage/Min.: -327.68 V, Max.: 327.67 V | SOC 55 to 60%: 16 V or more | - |
| Minimum Batt Block No | Battery block number with Minimum voltage | One of numbers 1 to 15 | - |
| Batt Block Max Vol | Battery block maximum voltage/Min.: -327.68 V, Max.: 327.67 V | SOC 55 to 60%: 31 V or less | - |
| Max Battery Block No | Battery block number with maximum voltage | One of numbers 1 to 15 | - |
| Battery Block Vol -V01 to 15 | Battery block voltage/Min.: -327.68 V, Max.: 327.67 V | SOC 60%: 16 to 27 V | - |
| Internal Resistance R01 to 15 | Internal resistance of each battery block/Min.: 0 , Max.: 0.255 | Always: 0.01 to 0.1 | - |
| Battery Low Time | Battery low time/Min.: 0, Max.: 65,535 | - | - |
| DC Inhibit Time | DC inhibit time/Min.: 0, Max.: 65,535 | - | - |
| Battery too High Time | Battery too high time/Min.: 0, Max.: 65,535 | - | - |
| Hot Temperature Time | Hot temperature time/Min.: 0, Max.: 65,535 | - | - |
| ACTIVE TEST |
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Enter the following menus: Powertrain / Hybrid Control / Active Test.
According to the display on the Techstream, perform the appropriate active test.
| Tester Display | Test Part | Control Range | Test Details | Test Condition |
| Forcible Stop of Inverter Drive | To determine if there is an internal leak in the inverter or the hybrid vehicle control ECU | ON / OFF | Keeps the inverter power transistor actuation signal ON | Power switch on (IG), shift lever in the P position, HV system normal, inverter actuation not being forcibly interrupted, during shutdown, and other active tests not being done |
| Compression Test *1 | To crank the engine continuously in order to measure the compression | ON / OFF | Allows the engine to continue cranking by activating MG1 continuously | Power switch on (IG), HV system normal, not in cranking mode, and other active tests not being done |
| Activate the Water Pump | To activate the water pump continuously | ON / OFF | Activates the hybrid vehicle water pump continuously | Power switch on (IG), HV system normal, not in inspection mode, and other active tests not being done |
| Driving the Battery Cooling Fan | To check operation of the cooling fan and if there is sufficient air flow | 0 to 6 | Stops the cooling fan or changes air volume mode | - |
| Connect the TC and TE1 | Batch display of warnings on combination meter | ON / OFF | TC terminal can be switched ON/OFF | Power switch on (IG), HV system is normal |