HYBRID BATTERY SYSTEM > PRECAUTION |
| 1.PRECAUTIONS FOR INSPECTING HYBRID BATTERY SYSTEM |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.

![]() |
After removing the inverter cover, wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
Wear protective goggles to prevent eye injury from electrolyte leakage when checking inside the HV battery.
Check the voltage at the terminals in the inspection point in the inverter with converter assembly.
Remove the inverter cover (Click here).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Inspection point | 5 minutes passed after removing the service plug grip | 0 V |
When turning the power switch on (IG) during inspections, do not press the power switch with the brake pedal depressed.
Turn the power switch off, wear insulated gloves, and disconnect the negative terminal of the auxiliary battery before touching any of the orange-colored wires of the high-voltage system.
Turn the power switch off before performing any resistance checks.
Turn the power switch off before disconnecting or reconnecting any connectors.
When high-voltage connectors are removed, wrap the connectors with insulating tape to prevent them from contacting foreign objects.
| 2.PRECAUTIONS FOR HYBRID BATTERY SYSTEM ACTIVATION |
When the warning light is illuminated, or the auxiliary battery has been disconnected and reconnected, attempting to turn the power switch on (READY) may not start the system (the system may not enter the READY-on state) on the first attempt. If so, turn the power switch off and reattempt to start the hybrid system.