Home › HYBRID SYSTEM · P310 › HYBRID BATTERY CONTROL › HYBRID BATTERY SYSTEM

HYBRID BATTERY SYSTEM > TERMINALS OF ECU

for Preparation Click here



A108228E05


ECU TERMINAL CHART 
Terminal No.
(Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
z18-1 (IGCT) - z18-8 (GND)
R - W-B
Control signal
Power switch on (READY)
11 to 14 V
z18-3 (VM0) - z18-8 (GND)
L - W-B
Cooling fan monitor signal
Cooling fan activation
0 to 10 V
z18-4 (VM1) - z18-8 (GND)
P - W-B
Cooling fan monitor signal
Cooling fan activation
0 to 10 V
z18-5 (VM2) - z18-8 (GND)
O - W-B
Cooling fan monitor signal
Cooling fan activation
0 to 10 V
z18-7 (BTH+) - z18-8 (GND)
Y - W-B
Serial communication
Power switch on (IG)
Pulse generation
(see waveform 1)
z18-14 (BTH-) - z18-8 (GND)
BR - W-B
Serial communication
Power switch on (IG)
Pulse generation
(see waveform 2)
z33-1 (TB0) - z33-6 (GB0)
W - W
HV battery temperature sensor 0
HV battery temperature: -40 to 194°F (-40 to 90°C)
1.0 to 4.8 V
z33-2 (TB1) - z33-7 (GB1)
L - L
HV battery temperature sensor 1
HV battery temperature: -40 to 194°F (-40 to 90°C)
1.0 to 4.8 V
z34-1 (TB2) - z34-4 (GB2)
R - R
HV battery temperature sensor 2
HV battery temperature: -40 to 194°F (-40 to 90°C)
1.0 to 4.8 V
z34-2 (TB3) - z34-5 (GB3)
W - W
HV battery temperature sensor 3
HV battery temperature: -40 to 194°F (-40 to 90°C)
1.0 to 4.8 V
z34-3 (TB4) - z34-6 (GB4)
G - G
HV battery temperature sensor 4
HV battery temperature: -40 to 194°F (-40 to 90°C)
1.0 to 4.8 V
z33-3 (TB5) - z33-8 (GB5)
R - R
HV battery temperature sensor 5
HV battery temperature: -40 to 194°F (-40 to 90°C)
1.0 to 4.8 V
z33-4 (TB6) - z33-9 (GB6)
O - O
HV battery temperature sensor 6
HV battery temperature: -40 to 194°F (-40 to 90°C)
1.0 to 4.8 V
z33-5 (TB7) - z33-10 (GB7)
G - G
HV battery temperature sensor 7
HV battery temperature: -40 to 194°F (-40 to 90°C)
1.0 to 4.8 V
z18-10 (VIB) - z18-12 (GIB)
Y-B - V
Power source of battery current sensor
Power switch on (IG)
4.5 to 5.5 V
z18-11 (IB) - z18-12 (GIB)
BR-B - V
Battery current sensor
Power switch on (READY)
0.5 to 4.5 V
z18-8 (GND) - Body ground
W-B - body ground
Ground
Always (resistance check)
Below 6 Ω

Oscilloscope waveform

HINT:
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.



    A112888E01
  1. Waveform 1
    Item
    Contents
    Terminal
    z18-7 (BTH+) - z18-8 (GND)
    Equipment Setting
    2 V/DIV, 500 μs/DIV
    Condition
    Power switch on (IG)

    HINT:
    The waveform shown in the illustration varies depending on the contents of the communication.



  2. A112889E01
  3. Waveform 2
    Item
    Contents
    Terminal
    z18-14 (BTH-) - z18-8 (GND)
    Equipment Setting
    2 V/DIV, 500 μs/DIV
    Condition
    Power switch on (IG)

    HINT:
    The waveform shown in the illustration varies depending on the contents of the communication.