Home › HYBRID SYSTEM ยท P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

HYBRID CONTROL SYSTEM > INFORMATION / FREEZE FRAME DATA

for Preparation Click here



FREEZE FRAME DATA

HINT:
The hybrid vehicle control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred. To confirm the details of the hybrid control system, check the detailed information for the DTC information code in the data list (INF code).

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch on (IG) and turn the tester on.

  3. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  4. Select a DTC in order to display its freeze frame data.

  5. Check the freeze frame information recorded with the DTC.

    Freeze Frame Data: 
    Tester Display
    Measurement Item / Range (Display)
    Suspected Vehicle Status When Malfunction Occurs
    Information 1 to 5
    Information code
    -
    Engine Coolant Temp
    Engine coolant temperature /
    Min.: -40°F (-40°C), Max.: 284°F (140°C)
    Cold or warmed-up engine
    Engine Revolution
    Engine speed /
    Min.: 0 rpm, Max.: 16,383.75 rpm
    Engine speed
    Vehicle Spd
    Vehicle speed /
    Min.: 0 MPH (0 km/h), Max.: 158 MPH (255 km/h)
    Stopped, or driving (at low, medium, or high speeds)
    Engine Run Time
    Elapsed time after engine start /
    Min.: 0 sec., Max.: 65535 sec.
    Elapsed time after engine start
    +B
    Auxiliary battery voltage /
    Min.: 0 V, Max.: 65.535 V
    Auxiliary battery condition
    Accel Pedal Pos #1
    Accelerator pedal position sensor No. 1 /
    Min.: 0%, Max.: 100%
    Idling, accelerating, or decelerating
    Accel Pedal Pos #2
    Accelerator pedal position sensor No. 2 /
    Min.: 0%, Max.: 100%
    For comparison with accelerator pedal position sensor No. 1
    Ambient Temperature
    Ambient air temperature /
    Min.: -40°F (-40°C), Max.: 419°F (215°C)
    Hot or cold weather
    Intake Air Temperature
    Intake air temperature /
    Min.: -40°F (-40°C), Max.: 284°F (140°C)
    Hot or cold weather
    DTC Clear Warm Up
    The number of times the engine is warmed up after clearing DTCs /
    Min.: 0, Max.: 255
    Frequency of malfunction recurrence after clearing DTCs
    DTC Clear Run Distance
    Drive distance after clearing DTCs /
    Min.: 0 mile (0 km), Max.: 40,723 mile (65,535 km)
    Frequency of malfunction recurrence after clearing DTCs
    DTC Clear Min
    Elapsed time after clearing DTCs /
    Min.: 0 Min, Max.: 65,535 Min
    Elapsed time after clearing DTCs
    Type of ECU
    ECU type / HV ECU
    -
    Calculate Load
    Calculate load /
    Min.: 0%, Max.: 100%
    -
    Throttle Position
    Throttle position sensor /
    Min.: 0%, Max.: 100%
    Idling, accelerating, or decelerating
    Battery State of Charge
    Battery state of charge /
    Min.: 0%, Max.: 127.5%
    State of charge of HV battery
    Delta SOC
    Battery state of charge /
    Min.: 0%, Max.: 100%
    SOC variance
    Batt Pack Current Val
    Battery pack current value /
    Min.: -327.68 A, Max.: 327.67 A
    HV battery charge/discharge status
    1. Amount of current during discharge is displayed with positive values
    2. Amount of current during charge is displayed with negative values
    VMF Fan Motor Voltage1 to 3
    VMF fan voltage /
    Min.: 0 V, Max.: 25.4 V
    Cooling fan operation condition
    Auxiliary Battery Vol
    Auxiliary battery voltage /
    Min.: 0 V, Max.: 25.4 V
    Auxiliary battery voltage
    Charge Control Value
    Charge control power value / Min.: -64 kW, Max.: 63.5 kW
    Charge amount of HV battery
    Discharge Control Value
    Discharge control power value / Min.: -64 kW, Max.: 63.5 kW
    Discharge amount of HV battery
    Cooling Fan Mode1 to 3
    Cooling fan mode 1 to 3
    HV battery cooling fan activation condition
    1. Stopped: 0
    2. Low speed drive - high speed drive: 1-6
    ECU Control Mode
    ECU control mode
    HV battery control status
    Standby Blower Request
    Standby blower request
    -
    Temp of Batt TB 1 to 8
    Battery temperature /
    Min.: -557.824°F (-327.68°C) , Max.: 621.806°F (327.67 °C)
    HV battery temperature
    Battery Block Vol -V01 to V15
    Battery block voltage /
    Min.: -327.68 V, Max.: 327.67 V
    Each HV battery block voltage variance
    Detail Code 1 to 5
    Information code
    -


INFORMATION

HINT:
Similar to freeze frame data, the hybrid vehicle control ECU also records vehicle and driving condition information as INFORMATION (INF code) at the moment a DTC is stored.

  1. Select the information which has an INF code from among "Information 1 to 5".

  2. Check the information of the DTC.

    Information: 
    Tester Display
    Measurement Item / Range (Display)
    Suspected Vehicle Status When Malfunction Occurs
    Generator(MG1) Rev
    MG1 revolution /
    Min.: -16,384 rpm , Max.: 16,256 rpm
    MG1 speed
    1. Forward rotation appears as "+"
    2. Backward rotation appears as "-"
    Motor(MG2) Revolution
    MG2 revolution /
    Min.: -16,384 rpm , Max.: 16,256 rpm
    MG2 speed (proportional to vehicle speed)
    1. Forward rotation appears as "+"
    2. Backward rotation appears as "-"
    Moving direction of vehicle
    1. Forward rotation appears as "+"
    2. Backward rotation appears as "-"
    Rear Motor Revolution
    MGR revolution /
    Min.: -16,384 rpm , Max.: 16,256 rpm
    MGR speed
    1. Forward rotation appears as "+"
    2. Backward rotation appears as "-"
    Generator(MG1) Torq
    MG1 torque /
    Min.: -512 Nm, Max.: 508 Nm
    When MG1 rotates in + direction:
    1. Torque appears as "+" while MG1 discharges
    2. Torque appears as "-" while MG1 charges
    When MG1 rotates in - direction:
    1. Torque appears as "-" while MG1 discharges
    2. Torque appears as "+" while MG1 charges
    Motor(MG2) Torq
    MG2 torque /
    Min.: -512 Nm, Max.: 508 Nm
    When MG2 rotates in + direction:
    1. Torque appears as "+" while MG2 discharges
    2. Torque appears as "-" while MG2 charges
    When MG2 rotates in - direction:
    1. Torque appears as "-" while MG2 discharges
    2. Torque appears as "+" while MG2 charges
    Rear Motor Torq
    MGR torque /
    Min.: -512 Nm, Max.: 508 Nm
    When MGR rotates in + direction:
    1. Torque appears as "+" while MGR discharges
    2. Torque appears as "-" while MGR charges
    When MGR rotates in - direction:
    1. Torque appears as "-" while MGR discharges
    2. Torque appears as "+" while MGR charges
    Inverter Temp (MG1)
    Generator inverter temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Generator inverter temperature
    Inverter Temp (MG2)
    Motor inverter temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Motor inverter temperature
    Rear Inverter Temp
    Rear motor inverter temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Rear Motor inverter temperature
    Motor Temp MG2 (No2)
    MG1 temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG1 temperature
    Motor Temp MG2 (No1)
    MG2 temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG2 temperature
    Rear Motor Temperature
    MGR temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MGR temperature
    Request Power
    Request engine power /
    Min.: 0 W, Max.: 320,000 W
    Engine power output requested to ECM
    Engine Spd
    Engine speed /
    Min.: 0 rpm , Max.: 16,320 rpm
    Engine speed
    Master Cylinder Ctrl Trq
    Master cylinder control torque /
    Min.: -512 Nm, Max.: 508 Nm
    Brake force requested by driver
    State of Charge
    Battery state of charge /
    Min.: 0%, Max.: 100%
    State of charge of HV battery
    WOUT Control Power
    Power value discharge control /
    Min.: 0 W, Max.: 81,600 W
    Discharge amount of HV battery
    WIN Control Power
    Power value charge control /
    Min.: -40,800 W, Max.: 0 W
    Charge amount of HV battery
    Drive Condition ID
    Drive condition ID
    1. Engine stopped: 0
    2. Engine about to be stopped: 1
    3. Engine about to be started: 2
    4. Engine operated or operating: 3
    5. Generating or loading movement: 4
    6. Revving in P position: 6
    Engine operating condition
    Power Resource VB
    HV battery voltage /
    Min.: 0 V, Max.: 510 V
    HV battery voltage
    Power Resource IB
    HV battery current /
    Min.: -256 A, Max.: 254 A
    HV battery current
    Shift Sensor Shift Pos
    Shift position (P, R, N, D or B position)
    P: 0, R: 1, N: 2, D: 3, B: 4
    Shift position
    Accel Sensor Main
    Accelerator pedal position sensor main /
    Min.: 0%, Max.: 100%
    Idling, accelerating, or decelerating
    Auxiliary Battery Voltage
    Auxiliary battery voltage /
    Min.: 0 V, Max.: 20 V
    Auxiliary battery voltage
    Converter Temperature
    Boost converter temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Boost converter temperature
    VL-Voltage before boosting
    High voltage before it is boosted /
    Min.: 0 V, Max.: 510 V
    High voltage level before it is boosted
    VH-Voltage after boosting
    High voltage after it is boosted
    Min.: 0 V, Max.: 765 V
    High voltage level after it is boosted
    The Time of Ignition ON
    Elapsed time after power switch on (IG) /
    Min.: 0 Min, Max.: 255 Min
    Time elapsed with power switch on (IG)
    Vehicle Speed(Max)
    Minimum state of charge /
    Min.: -159 MPH (-256 km/h), Max.: 158 MPH (254 km/h)
    Over-discharging of HV battery
    A/C Power
    Maximum vehicle speed /
    Min.: 0 kW, Max.: 5 kW
    A/C load
    Engine Stop Request
    Engine stop request / NO or YES
    Engine stop request
    Engine Idling Request
    Engine idling request / NO or YES
    Idle stop request
    Engine Fuel Cut
    Engine fuel cut request / NO or YES
    Fuel cut request
    Main Batt Charging Rqst
    HV battery charging request /
    No or YES
    HV battery charging request
    HCAC OBD Request
    HCAC OBD Request / NO or RQST
    HCAC OBD request
    Engine Warming Up Rqst
    Engine warming up request / NO or YES
    Engine warm-up request
    Stop Switch
    Stop light switch ON condition / NO or YES
    Brake pedal depressed or released
    Cruise Control
    Cruise control active condition / NO or YES
    Operation under cruise control ON or OFF
    Exclusive Information 1 to 7
    Exclusive information (in numerical data)
    Exclusive Information linked to Information
    Occurrence Order
    Occurrence sequence of information
    Occurrence sequence of information
    Inv-T (MG1) aftr IG-ON
    Generator inverter temperature after power switch on (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Generator inverter temperature soon after power switch on (IG)
    Inv-T (MG2) aftr IG-ON
    Motor inverter temperature after power switch on (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Motor inverter temperature soon after power switch on (IG)
    Mtr-T (MG2) aftr IG-ON
    MG2 temperature after power switch on (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG2 temperature soon after power switch on (IG)
    Rear Inv-T after IG-ON
    Rear motor inverter temperature after power switch on (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Rear Motor inverter temperature soon after power switch on (IG)
    Rear Mtr-T after IG-ON
    MGR temperature after power switch on (IG)
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MGR temperature soon after power switch on (IG)
    Cnv-Tmp after IG-ON
    Boost converter temperature after power switch on (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Boost converter temperature soon after power switch on (IG)
    SOC after IG-ON
    Battery state of charge after power switch on (IG) /
    Min.: 0%, Max.: 100%
    Battery state of charge soon after power switch on (IG)
    Inverter Tmp (MG1) Max
    Generator inverter maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of generator inverter
    Inverter Tmp (MG2) Max
    Motor inverter maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of motor inverter
    Motor Temp (MG2) Max
    MG2 maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of MG2
    Rear Inverter Temp Max
    Rear Motor inverter maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of Rear motor inverter
    Rear Motor Temp Max
    MGR maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of MGR
    Converter Temp Max
    Boost converter maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of boost converter
    Status of Charge Max
    Maximum state of charge /
    Min.: 0%, Max.: 100%
    Over-charging of HV battery
    Status of Charge Min
    Minimum state of charge/
    Min.: 0%, Max.: 100%
    Over-discharge of HV battery
    HV Coolant Temperature
    HV coolant temperature /
    Min.: -40°F (-40°C), Max.: 284°F (140°C)