HYBRID CONTROL SYSTEM > INFORMATION / FREEZE FRAME DATA |
| FREEZE FRAME DATA |
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the tester on.
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Select a DTC in order to display its freeze frame data.
Check the freeze frame information recorded with the DTC.
| Tester Display | Measurement Item / Range (Display) | Suspected Vehicle Status When Malfunction Occurs |
| Information 1 to 5 | Information code | - |
| Engine Coolant Temp | Engine coolant temperature / Min.: -40°F (-40°C), Max.: 284°F (140°C) | Cold or warmed-up engine |
| Engine Revolution | Engine speed / Min.: 0 rpm, Max.: 16,383.75 rpm | Engine speed |
| Vehicle Spd | Vehicle speed / Min.: 0 MPH (0 km/h), Max.: 158 MPH (255 km/h) | Stopped, or driving (at low, medium, or high speeds) |
| Engine Run Time | Elapsed time after engine start / Min.: 0 sec., Max.: 65535 sec. | Elapsed time after engine start |
| +B | Auxiliary battery voltage / Min.: 0 V, Max.: 65.535 V | Auxiliary battery condition |
| Accel Pedal Pos #1 | Accelerator pedal position sensor No. 1 / Min.: 0%, Max.: 100% | Idling, accelerating, or decelerating |
| Accel Pedal Pos #2 | Accelerator pedal position sensor No. 2 / Min.: 0%, Max.: 100% | For comparison with accelerator pedal position sensor No. 1 |
| Ambient Temperature | Ambient air temperature / Min.: -40°F (-40°C), Max.: 419°F (215°C) | Hot or cold weather |
| Intake Air Temperature | Intake air temperature / Min.: -40°F (-40°C), Max.: 284°F (140°C) | Hot or cold weather |
| DTC Clear Warm Up | The number of times the engine is warmed up after clearing DTCs / Min.: 0, Max.: 255 | Frequency of malfunction recurrence after clearing DTCs |
| DTC Clear Run Distance | Drive distance after clearing DTCs / Min.: 0 mile (0 km), Max.: 40,723 mile (65,535 km) | Frequency of malfunction recurrence after clearing DTCs |
| DTC Clear Min | Elapsed time after clearing DTCs / Min.: 0 Min, Max.: 65,535 Min | Elapsed time after clearing DTCs |
| Type of ECU | ECU type / HV ECU | - |
| Calculate Load | Calculate load / Min.: 0%, Max.: 100% | - |
| Throttle Position | Throttle position sensor / Min.: 0%, Max.: 100% | Idling, accelerating, or decelerating |
| Battery State of Charge | Battery state of charge / Min.: 0%, Max.: 127.5% | State of charge of HV battery |
| Delta SOC | Battery state of charge / Min.: 0%, Max.: 100% | SOC variance |
| Batt Pack Current Val | Battery pack current value / Min.: -327.68 A, Max.: 327.67 A | HV battery charge/discharge status
|
| VMF Fan Motor Voltage1 to 3 | VMF fan voltage / Min.: 0 V, Max.: 25.4 V | Cooling fan operation condition |
| Auxiliary Battery Vol | Auxiliary battery voltage / Min.: 0 V, Max.: 25.4 V | Auxiliary battery voltage |
| Charge Control Value | Charge control power value / Min.: -64 kW, Max.: 63.5 kW | Charge amount of HV battery |
| Discharge Control Value | Discharge control power value / Min.: -64 kW, Max.: 63.5 kW | Discharge amount of HV battery |
| Cooling Fan Mode1 to 3 | Cooling fan mode 1 to 3 | HV battery cooling fan activation condition
|
| ECU Control Mode | ECU control mode | HV battery control status |
| Standby Blower Request | Standby blower request | - |
| Temp of Batt TB 1 to 8 | Battery temperature / Min.: -557.824°F (-327.68°C) , Max.: 621.806°F (327.67 °C) | HV battery temperature |
| Battery Block Vol -V01 to V15 | Battery block voltage / Min.: -327.68 V, Max.: 327.67 V | Each HV battery block voltage variance |
| Detail Code 1 to 5 | Information code | - |
| INFORMATION |
Select the information which has an INF code from among "Information 1 to 5".
Check the information of the DTC.
| Tester Display | Measurement Item / Range (Display) | Suspected Vehicle Status When Malfunction Occurs |
| Generator(MG1) Rev | MG1 revolution / Min.: -16,384 rpm , Max.: 16,256 rpm | MG1 speed
|
| Motor(MG2) Revolution | MG2 revolution / Min.: -16,384 rpm , Max.: 16,256 rpm | MG2 speed (proportional to vehicle speed)
|
| Rear Motor Revolution | MGR revolution / Min.: -16,384 rpm , Max.: 16,256 rpm | MGR speed
|
| Generator(MG1) Torq | MG1 torque / Min.: -512 Nm, Max.: 508 Nm | When MG1 rotates in + direction:
|
| Motor(MG2) Torq | MG2 torque / Min.: -512 Nm, Max.: 508 Nm | When MG2 rotates in + direction:
|
| Rear Motor Torq | MGR torque / Min.: -512 Nm, Max.: 508 Nm | When MGR rotates in + direction:
|
| Inverter Temp (MG1) | Generator inverter temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Generator inverter temperature |
| Inverter Temp (MG2) | Motor inverter temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Motor inverter temperature |
| Rear Inverter Temp | Rear motor inverter temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Rear Motor inverter temperature |
| Motor Temp MG2 (No2) | MG1 temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | MG1 temperature |
| Motor Temp MG2 (No1) | MG2 temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | MG2 temperature |
| Rear Motor Temperature | MGR temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | MGR temperature |
| Request Power | Request engine power / Min.: 0 W, Max.: 320,000 W | Engine power output requested to ECM |
| Engine Spd | Engine speed / Min.: 0 rpm , Max.: 16,320 rpm | Engine speed |
| Master Cylinder Ctrl Trq | Master cylinder control torque / Min.: -512 Nm, Max.: 508 Nm | Brake force requested by driver |
| State of Charge | Battery state of charge / Min.: 0%, Max.: 100% | State of charge of HV battery |
| WOUT Control Power | Power value discharge control / Min.: 0 W, Max.: 81,600 W | Discharge amount of HV battery |
| WIN Control Power | Power value charge control / Min.: -40,800 W, Max.: 0 W | Charge amount of HV battery |
| Drive Condition ID | Drive condition ID
| Engine operating condition |
| Power Resource VB | HV battery voltage / Min.: 0 V, Max.: 510 V | HV battery voltage |
| Power Resource IB | HV battery current / Min.: -256 A, Max.: 254 A | HV battery current |
| Shift Sensor Shift Pos | Shift position (P, R, N, D or B position) P: 0, R: 1, N: 2, D: 3, B: 4 | Shift position |
| Accel Sensor Main | Accelerator pedal position sensor main / Min.: 0%, Max.: 100% | Idling, accelerating, or decelerating |
| Auxiliary Battery Voltage | Auxiliary battery voltage / Min.: 0 V, Max.: 20 V | Auxiliary battery voltage |
| Converter Temperature | Boost converter temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Boost converter temperature |
| VL-Voltage before boosting | High voltage before it is boosted / Min.: 0 V, Max.: 510 V | High voltage level before it is boosted |
| VH-Voltage after boosting | High voltage after it is boosted Min.: 0 V, Max.: 765 V | High voltage level after it is boosted |
| The Time of Ignition ON | Elapsed time after power switch on (IG) / Min.: 0 Min, Max.: 255 Min | Time elapsed with power switch on (IG) |
| Vehicle Speed(Max) | Minimum state of charge / Min.: -159 MPH (-256 km/h), Max.: 158 MPH (254 km/h) | Over-discharging of HV battery |
| A/C Power | Maximum vehicle speed / Min.: 0 kW, Max.: 5 kW | A/C load |
| Engine Stop Request | Engine stop request / NO or YES | Engine stop request |
| Engine Idling Request | Engine idling request / NO or YES | Idle stop request |
| Engine Fuel Cut | Engine fuel cut request / NO or YES | Fuel cut request |
| Main Batt Charging Rqst | HV battery charging request / No or YES | HV battery charging request |
| HCAC OBD Request | HCAC OBD Request / NO or RQST | HCAC OBD request |
| Engine Warming Up Rqst | Engine warming up request / NO or YES | Engine warm-up request |
| Stop Switch | Stop light switch ON condition / NO or YES | Brake pedal depressed or released |
| Cruise Control | Cruise control active condition / NO or YES | Operation under cruise control ON or OFF |
| Exclusive Information 1 to 7 | Exclusive information (in numerical data) | Exclusive Information linked to Information |
| Occurrence Order | Occurrence sequence of information | Occurrence sequence of information |
| Inv-T (MG1) aftr IG-ON | Generator inverter temperature after power switch on (IG) / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Generator inverter temperature soon after power switch on (IG) |
| Inv-T (MG2) aftr IG-ON | Motor inverter temperature after power switch on (IG) / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Motor inverter temperature soon after power switch on (IG) |
| Mtr-T (MG2) aftr IG-ON | MG2 temperature after power switch on (IG) / Min.: -58°F (-50°C), Max.: 401°F (205°C) | MG2 temperature soon after power switch on (IG) |
| Rear Inv-T after IG-ON | Rear motor inverter temperature after power switch on (IG) / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Rear Motor inverter temperature soon after power switch on (IG) |
| Rear Mtr-T after IG-ON | MGR temperature after power switch on (IG) Min.: -58°F (-50°C), Max.: 401°F (205°C) | MGR temperature soon after power switch on (IG) |
| Cnv-Tmp after IG-ON | Boost converter temperature after power switch on (IG) / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Boost converter temperature soon after power switch on (IG) |
| SOC after IG-ON | Battery state of charge after power switch on (IG) / Min.: 0%, Max.: 100% | Battery state of charge soon after power switch on (IG) |
| Inverter Tmp (MG1) Max | Generator inverter maximum temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Overheating state of generator inverter |
| Inverter Tmp (MG2) Max | Motor inverter maximum temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Overheating state of motor inverter |
| Motor Temp (MG2) Max | MG2 maximum temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Overheating state of MG2 |
| Rear Inverter Temp Max | Rear Motor inverter maximum temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Overheating state of Rear motor inverter |
| Rear Motor Temp Max | MGR maximum temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Overheating state of MGR |
| Converter Temp Max | Boost converter maximum temperature / Min.: -58°F (-50°C), Max.: 401°F (205°C) | Overheating state of boost converter |
| Status of Charge Max | Maximum state of charge / Min.: 0%, Max.: 100% | Over-charging of HV battery |
| Status of Charge Min | Minimum state of charge/ Min.: 0%, Max.: 100% | Over-discharge of HV battery |
| HV Coolant Temperature | HV coolant temperature / Min.: -40°F (-40°C), Max.: 284°F (140°C) | HV coolant temperature |