Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY
RM3160E _57 Power Source / Network _019703 POWER DISTRIBUTION _0100675 INTEGRATION RELAY G

POWER DISTRIBUTION  INTEGRATION RELAY  INSPECTION  


PROCEDURE

Hide 82644 1.INSPECT SEMICONDUCTOR PWR INTEGRATION ECU

E256823
0.5,0.906 0.75,1.104 0.25,0.198 10 false 1B 0.531,0.708 0.677,0.865 0.146,0.156 10 false 1 6.51,0.51 6.76,0.708 0.25,0.198 10 false 1F 6.49,1.698 6.74,1.896 0.25,0.198 10 false 1E 6.49,1.302 6.74,1.5 0.25,0.198 10 false 1G 1.5,1.073 2.302,1.271 0.802,0.198 10 false IG2-MAIN 1.49,2.479 2.146,2.677 0.656,0.198 10 false EFI-MAIN 2.74,2.75 3.396,2.948 0.656,0.198 10 false EFI MAIN 2.917,1.344 3.229,1.542 0.313,0.198 10 false IG2 4.74,1.063 5.313,1.271 0.573,0.208 10 false IG2-EFI 4.865,1.458 5.146,1.635 0.281,0.177 10 false INJ 6.49,2.698 6.74,2.896 0.25,0.198 10 false 1G 6.49,0.906 6.74,1.104 0.25,0.198 10 false 1G 6.49,2.292 6.74,2.49 0.25,0.198 10 false 1G 6.5,3.094 6.75,3.292 0.25,0.198 10 false 1G 6.5,3.49 6.75,3.688 0.25,0.198 10 false 1G 6.5,3.885 6.75,4.083 0.25,0.198 10 false 1G 6.51,4.281 6.76,4.479 0.25,0.198 10 false 1F 6.5,5.469 6.75,5.667 0.25,0.198 10 false 1E 6.51,4.677 6.76,4.875 0.25,0.198 10 false 1F 6.5,6.677 6.75,6.875 0.25,0.198 10 false 1D 6.5,6.271 6.75,6.469 0.25,0.198 10 false 1E 6.5,7.656 6.781,7.865 0.281,0.208 10 false 1G 6.5,7.26 6.781,7.469 0.281,0.208 10 false 1D 6.542,1.115 6.698,1.313 0.156,0.198 10 false 3 6.531,2.083 6.688,2.281 0.156,0.198 10 false 1 6.552,0.719 6.698,0.969 0.146,0.25 10 false 4 6.542,0.302 6.698,0.51 0.156,0.208 10 false 4 6.542,1.5 6.698,1.698 0.156,0.198 10 false 1 6.531,2.5 6.688,2.698 0.156,0.198 10 false 2 6.542,2.896 6.719,3.094 0.177,0.198 10 false 7 6.542,3.302 6.719,3.5 0.177,0.198 10 false 8 6.542,3.688 6.729,3.927 0.188,0.24 10 false 6 6.542,4.094 6.719,4.292 0.177,0.198 10 false 2 6.542,6.073 6.729,6.292 0.188,0.219 10 false 3 6.542,4.479 6.729,4.698 0.188,0.219 10 false 1 6.542,5.281 6.729,5.5 0.188,0.219 10 false 2 6.542,6.479 6.729,6.698 0.188,0.219 10 false 8 6.5,7.063 6.698,7.25 0.198,0.188 10 false 14 6.542,7.469 6.698,7.667 0.156,0.198 10 false 5 1.563,4.854 2.198,5.063 0.635,0.208 10 false A/F HTR 1.385,5.656 2.219,5.865 0.833,0.208 10 false H-LP LO RH 1.396,6.448 2.292,6.667 0.896,0.219 10 false H-LP LO LH 2.927,5.125 3.25,5.323 0.323,0.198 10 false A/F 2.688,6.969 3.583,7.188 0.896,0.219 10 false H-LP LH-LO 2.688,5.917 3.583,6.135 0.896,0.219 10 false H-LP RH-LO 2.365,8.354 4.75,8.563 2.385,0.208 10 false Semiconductor Pwr Integration ECU 4.667,2.469 5.354,2.698 0.688,0.229 10 false EFI NO. 2

a.

IG2 RELAY:

i.
A293777
1.115,0.646 1.375,0.823 0.26,0.177 1.5,0.646 1.76,0.823 0.26,0.177 1.938,0.646 2.198,0.823 0.26,0.177 2.781,0.646 3.042,0.823 0.26,0.177 2.333,0.646 2.594,0.823 0.26,0.177 0,0 0.313,0.156 0.313,0.156 10 false *a 2,0.646 2.313,0.844 0.313,0.198 10 false 1F 2.833,0.646 3.146,0.844 0.313,0.198 10 false 1B 1.552,0.646 1.865,0.844 0.313,0.198 10 false 1E 1.177,0.646 1.49,0.844 0.313,0.198 10 false 1D 2.385,0.646 2.698,0.844 0.313,0.198 10 false 1G
*a Component without harness connected
(Semiconductor Pwr Integration ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1B-1 - 1F-4 Battery voltage is not applied between terminals 1E-1 and 1D-14 10 kΩ or higher
1B-1 - 1G-3
1B-1 - 1G-4
1B-1 - 1F-4 Battery positive (+) → 1E-1
Battery negative (-) → 1D-14
Below 1 Ω
1B-1 - 1G-3
1B-1 - 1G-4


If the resistance is not as specified, replace the semiconductor pwr integration ECU.



b.

EFI MAIN RELAY:

i.
A293777
1.115,0.635 1.375,0.813 0.26,0.177 1.938,0.635 2.198,0.813 0.26,0.177 2.365,0.635 2.625,0.813 0.26,0.177 2.771,0.635 3.031,0.813 0.26,0.177 0,0 0.313,0.156 0.313,0.156 10 false *a 2,0.635 2.313,0.833 0.313,0.198 10 false 1F 2.406,0.635 2.719,0.833 0.313,0.198 10 false 1G 1.167,0.635 1.479,0.833 0.313,0.198 10 false 1D 2.823,0.635 3.135,0.833 0.313,0.198 10 false 1B
*a Component without harness connected
(Semiconductor Pwr Integration ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1B-1 - 1G-1 Battery voltage is not applied between terminals 1G-6 and 1D-14 10 kΩ or higher
1B-1 - 1G-2
1B-1 - 1G-7
1B-1 - 1G-8
1F-2 - 1G-1
1B-1 - 1G-1 Battery positive (+) → 1G-6
Battery negative (-) → 1D-14
Below 1 Ω
1B-1 - 1G-2
1B-1 - 1G-7
1B-1 - 1G-8
1F-2 - 1G-1


If the resistance is not as specified, replace the semiconductor pwr integration ECU.



c.

A/F RELAY:

i.
A293777
1.115,0.646 1.375,0.823 0.26,0.177 2.375,0.646 2.635,0.823 0.26,0.177 1.938,0.646 2.198,0.823 0.26,0.177 2.781,0.646 3.042,0.823 0.26,0.177 0,0 0.313,0.156 0.313,0.156 10 false *a 2,0.646 2.313,0.844 0.313,0.198 10 false 1F 2.833,0.646 3.146,0.844 0.313,0.198 10 false 1B 2.427,0.646 2.74,0.844 0.313,0.198 10 false 1G 1.167,0.646 1.479,0.844 0.313,0.198 10 false 1D
*a Component without harness connected
(Semiconductor Pwr Integration ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1B-1 - 1F-1 Battery voltage is not applied between terminals 1G-1 and 1D-14 10 kΩ or higher
1B-1 - 1F-1 Battery positive (+) → 1G-1
Battery negative (-) → 1D-14
Below 1 Ω


If the resistance is not as specified, replace the semiconductor pwr integration ECU.



d.

H-LP RH-LO RELAY:

i.
A293777
1.115,0.646 1.375,0.823 0.26,0.177 1.5,0.646 1.76,0.823 0.26,0.177 2.781,0.635 3.042,0.813 0.26,0.177 0,0 0.313,0.156 0.313,0.156 10 false *a 2.833,0.635 3.146,0.833 0.313,0.198 10 false 1B 1.552,0.646 1.865,0.844 0.313,0.198 10 false 1E 1.177,0.646 1.49,0.844 0.313,0.198 10 false 1D
*a Component without harness connected
(Semiconductor Pwr Integration ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1B-1 - 1E-2 Battery voltage is not applied between terminals 1B-1 and 1D-8 10 kΩ or higher



ii.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1E-2 - Battery negative (-) Battery positive (+) → 1B-1
Battery negative (-) → 1D-8
11 to 14 V


If the result is not as specified, replace the semiconductor pwr integration ECU.



e.

H-LP LH-LO RELAY:

i.
A293777
1.115,0.656 1.375,0.833 0.26,0.177 1.5,0.656 1.76,0.833 0.26,0.177 2.781,0.646 3.042,0.823 0.26,0.177 0,0 0.313,0.156 0.313,0.156 10 false *a 2.833,0.646 3.146,0.844 0.313,0.198 10 false 1B 1.552,0.656 1.865,0.854 0.313,0.198 10 false 1E 1.167,0.656 1.479,0.854 0.313,0.198 10 false 1D
*a Component without harness connected
(Semiconductor Pwr Integration ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1B-1 - 1E-3 Battery voltage is not applied between terminals 1B-1 and 1D-8 10 kΩ or higher



ii.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1E-3 - Battery negative (-) Battery positive (+) → 1B-1
Battery negative (-) → 1D-8
11 to 14 V


If the result is not as specified, replace the semiconductor pwr integration ECU.



f.

Semiconductor pwr integration ECU ground:

i.
A293777
1.115,0.656 1.375,0.833 0.26,0.177 2.354,0.646 2.615,0.823 0.26,0.177 0,0 0.313,0.156 0.313,0.156 10 false *a 2.396,0.646 2.708,0.844 0.313,0.198 10 false 1G 1.167,0.656 1.479,0.854 0.313,0.198 10 false 1D
*a Component without harness connected
(Semiconductor Pwr Integration ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1D-14 - 1G-5 Always Below 1 Ω


If the resistance is not as specified, replace the semiconductor pwr integration ECU.