RM3160E
_V1
General
_019682
SPECIFICATIONS
_0095392
BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS
F
SPECIFICATIONS BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS SERVICE DATA
- VSC OFF Switch:
| Tester Connection
|
Condition
|
Specified Condition
|
| 6 (+) - 3 (E)
|
Switch pushed
|
Below 1 Ω
|
| 6 (+) - 3 (E)
|
Switch not pushed
|
10 kΩ or higher
|
- Brake Pedal Load Sensing Switch:
| Tester Connection
|
Condition
|
Specified Condition
|
| 2 (FSW+) - 1(FSW-)
|
Switch OFF (Brake pedal depressed)
|
950 to 1050 Ω
|
| 2 (FSW+) - 1(FSW-)
|
Switch ON (Brake pedal released)
|
203 to 223 Ω
|
- Downhill Assist Control Switch:
| Tester Connection
|
Condition
|
Specified Condition
|
| 4 (B) - 1 (E)
|
Switch pushed
|
Below 1 Ω
|
| 4 (B) - 1 (E)
|
Switch not pushed
|
10 kΩ or higher
|
- Stop Light Control Relay:
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 4
|
Voltage is not applied between terminals 1 and 2
|
Below 1 Ω
|
| 3 - 5
|
Voltage is not applied between terminals 1 and 2
|
10 kΩ or higher
|
| 3 - 4
|
Voltage is applied between terminals 1 and 2
|
10 kΩ or higher
|
| 3 - 5
|
Voltage is applied between terminals 1 and 2
|
Below 1 Ω
|