Home › Engine / Hybrid System › 2GR-FE EMISSION CONTROL › PURGE VALVE › 2013.12–2016.11
RM3160E _51 Engine / Hybrid System _019665 2GR-FE EMISSION CONTROL _0104498 PURGE VALVE G

2GR-FE EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 25860A 1.INSPECT PURGE VALVE (PURGE VSV)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω


If the result is not as specified, replace the purge valve (purge VSV).


b.
A192097C01
1.365,1.427 1.365,0.792 true 0.49,0.229 0.677,0.229 0.677,0.229 0.906,0.625 true 1.323,1.438 1.792,1.833 0.469,0.396 10 false *a 0.323,0.125 0.625,0.417 0.302,0.292 10 false *b 2.083,1.563 2.688,2.104 0.604,0.542 10 false *c
*a Port (E)
*b Port (F)
*c Air


Apply battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).

Standard:
Condition Specified Condition
Battery voltage applied between terminals 1 and 2 Air flows from port (F)
Battery voltage not applied between terminals 1 and 2 Air does not flow


If the result is not as specified, replace the purge valve (purge VSV).