1AR-FE BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 27020 4.REMOVE GENERATOR ASSEMBLY

a.
A315027

Open the terminal cap.


b.

Remove the nut and disconnect the wire harness from terminal B.


c.

Disconnect the generator assembly connector.


d.

Remove the bolt and wire harness clamp bracket from the generator assembly.


e.
A315028

Remove the 2 bolts and generator assembly.