Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW REGULATOR MOTOR(for Rear Door)
RM3160E _59 Vehicle Exterior _019717 WINDOW / GLASS _0106117 POWER WINDOW REGULATOR MOTOR(for Rear Door) G

WINDOW / GLASS  POWER WINDOW REGULATOR MOTOR(for Rear Door)  INSPECTION  


PROCEDURE

Hide 85720E 1.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (w/ Jam Protection Function)

a.
B203475
1.219,2.531 1.219,2.208 1.219,2.208 1.615,2.208 false 1.094,2.521 1.083,2.208 1.083,2.208 0.542,2.208 false 1.229,2.708 1.229,3.042 1.229,3.042 1.458,3.042 false 1.052,2.708 1.052,3.031 1.052,3.031 0.615,3.031 false 0.135,0.083 0.313,0.333 0.177,0.25 10 *a 1.646,2.146 1.969,2.365 0.323,0.219 10 GND 1.49,2.948 1.948,3.094 0.458,0.146 10 DOWN 0.365,2.948 0.604,3.177 0.24,0.229 10 UP 0.406,2.135 0.552,2.354 0.146,0.219 10 B 2.958,1.854 3.188,2.083 0.229,0.229 10 *b 2.333,2.333 2.542,2.542 0.208,0.208 10 *c
*a Component without harness connected
(Power Window Regulator Motor Assembly LH)
*b Counterclockwise
*c Clockwise


Connect a positive (+) battery lead to terminal 2 (B).

NOTICE:

Do not connect a positive (+) battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.



b.

Connect a negative (-) battery lead to terminals 1 (GND) and 7 (DOWN) or 10 (UP).


c.

Check that the motor gear rotates smoothly as follows:

OK:
Battery Connection Specified Condition
1.

Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

2.

With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 10 (UP).

3.

Disconnect and reconnect the negative (-) battery lead to terminal 10 (UP) within 1 second.


Motor gear rotates clockwise
1.

Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

2.

With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 7 (DOWN).

3.

Disconnect and reconnect the negative (-) battery lead to terminal 7 (DOWN) within 1 second.


Motor gear rotates counterclockwise


If the result is not as specified, replace the power window regulator motor assembly LH.


NOTICE:

Initialize the power window control system after installing the power window regulator motor and regulator assembly.



Hide 85720E 2.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (w/o Jam Protection Function)

a.
B357789
0.229,0.146 0.542,0.302 0.313,0.156 10 false *a 1.813,1.885 2.125,2.042 0.313,0.156 10 false *b 3.073,0.917 3.385,1.073 0.313,0.156 10 false *c 2.802,1.677 3.115,1.833 0.313,0.156 10 false *d
*a Component without harness connected
(Power Window Regulator Motor Assembly LH)
*b Motor Gear
*c Counterclockwise
*d Clockwise


Apply battery voltage to the motor connector according to the table below.

NOTICE:

Do not apply battery voltage to any terminals except terminals 1 and 2.


OK:
Battery Connection Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Motor gear rotates clockwise
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Motor gear rotates counterclockwise


If the result is not as specified, replace the power window regulator motor assembly LH.


Hide 85710F 3.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (w/ Jam Protection Function)

a.
B203474
2.417,2.5 2.417,2.188 2.417,2.188 2.833,2.188 false 2.302,2.5 2.302,2.188 2.302,2.188 1.781,2.188 false 2.271,2.708 2.271,3 2.271,3 1.823,3 false 2.438,2.698 2.438,3 2.438,3 2.677,3 false 0.063,0.063 0.281,0.26 0.219,0.198 10 *a 2.677,2.927 3.208,3.135 0.531,0.208 10 DOWN 2.854,2.104 3.208,2.333 0.354,0.229 10 GND 1.667,2.104 1.813,2.313 0.146,0.208 10 B 1.563,2.927 1.802,3.115 0.24,0.188 10 UP 0.302,1.813 0.5,1.99 0.198,0.177 10 *b 0.948,2.24 1.177,2.469 0.229,0.229 10 *c
*a Component without harness connected
(Power Window Regulator Motor Assembly RH)
*b Clockwise
*c Counterclockwise


Connect a positive (+) battery lead to terminal 2 (B).

NOTICE:

Do not connect a positive (+) battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.



b.

Connect a negative (-) battery lead to terminals 1 (GND) and 7 (DOWN) or 10 (UP).


c.

Check that the motor gear rotates smoothly as follows:

OK:
Battery Connection Specified Condition
1.

Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

2.

With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 10 (UP).

3.

Disconnect and reconnect the negative (-) battery lead to terminal 10 (UP) within 1 second.


Motor gear rotates counterclockwise
1.

Connect a positive (+) battery lead to terminal 2 (B), connect the negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

2.

With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 7 (DOWN).

3.

Disconnect and reconnect the negative (-) battery lead to terminal 7 (DOWN) within 1 second.


Motor gear rotates clockwise


If the result is not as specified, replace the power window regulator motor assembly RH.


NOTICE:

Initialize the power window control system after installing the power window regulator motor and regulator assembly.



Hide 85710F 4.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (w/o Jam Protection Function)

a.
B357790
0.219,0.146 0.531,0.302 0.313,0.156 10 false *a 1.521,1.833 1.833,1.99 0.313,0.156 10 false *b 0.26,0.792 0.573,0.948 0.313,0.156 10 false *c 0.521,1.521 0.833,1.677 0.313,0.156 10 false *d
*a Component without harness connected
(Power Window Regulator Motor Assembly RH)
*b Motor Gear
*c Clockwise
*d Counterclockwise


Apply battery voltage to the motor connector according to the table below.

NOTICE:

Do not apply battery voltage to any terminals except terminals 1 and 2.


OK:
Battery Connection Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Motor gear rotates clockwise
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Motor gear rotates counterclockwise


If the result is not as specified, replace the power window regulator motor assembly RH.