85720E
1.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (w/ Jam Protection Function)
| *a | Component without harness connected
(Power Window Regulator Motor Assembly LH) |
| *b | Counterclockwise |
| *c | Clockwise |
Connect a positive (+) battery lead to terminal 2 (B).
Do not connect a positive (+) battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) battery lead to terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| Battery Connection | Specified Condition |
|---|---|
1.
Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 10 (UP). 3.
Disconnect and reconnect the negative (-) battery lead to terminal 10 (UP) within 1 second. |
Motor gear rotates clockwise |
1.
Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 7 (DOWN). 3.
Disconnect and reconnect the negative (-) battery lead to terminal 7 (DOWN) within 1 second. |
Motor gear rotates counterclockwise |
If the result is not as specified, replace the power window regulator motor assembly LH.
Initialize the power window control system after installing the power window regulator motor and regulator assembly.
85720E
2.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (w/o Jam Protection Function)
| *a | Component without harness connected
(Power Window Regulator Motor Assembly LH) |
| *b | Motor Gear |
| *c | Counterclockwise |
| *d | Clockwise |
Apply battery voltage to the motor connector according to the table below.
Do not apply battery voltage to any terminals except terminals 1 and 2.
| Battery Connection | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1 |
Motor gear rotates clockwise |
| Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2 |
Motor gear rotates counterclockwise |
If the result is not as specified, replace the power window regulator motor assembly LH.
85710F
3.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (w/ Jam Protection Function)
| *a | Component without harness connected
(Power Window Regulator Motor Assembly RH) |
| *b | Clockwise |
| *c | Counterclockwise |
Connect a positive (+) battery lead to terminal 2 (B).
Do not connect a positive (+) battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) battery lead to terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| Battery Connection | Specified Condition |
|---|---|
1.
Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 10 (UP). 3.
Disconnect and reconnect the negative (-) battery lead to terminal 10 (UP) within 1 second. |
Motor gear rotates counterclockwise |
1.
Connect a positive (+) battery lead to terminal 2 (B), connect the negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more. 2.
With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 7 (DOWN). 3.
Disconnect and reconnect the negative (-) battery lead to terminal 7 (DOWN) within 1 second. |
Motor gear rotates clockwise |
If the result is not as specified, replace the power window regulator motor assembly RH.
Initialize the power window control system after installing the power window regulator motor and regulator assembly.
85710F
4.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (w/o Jam Protection Function)
| *a | Component without harness connected
(Power Window Regulator Motor Assembly RH) |
| *b | Motor Gear |
| *c | Clockwise |
| *d | Counterclockwise |
Apply battery voltage to the motor connector according to the table below.
Do not apply battery voltage to any terminals except terminals 1 and 2.
| Battery Connection | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2 |
Motor gear rotates clockwise |
| Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1 |
Motor gear rotates counterclockwise |
If the result is not as specified, replace the power window regulator motor assembly RH.