Home › Engine / Hybrid System › 1AR-FE ENGINE CONTROL › HEATED OXYGEN SENSOR
RM3160E _51 Engine / Hybrid System _019671 1AR-FE ENGINE CONTROL _0106860 HEATED OXYGEN SENSOR G

1AR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR

a.
A317553
1.958,1.021 2.292,0.635 2.292,0.635 2.531,0.635 false 1.458,1.01 1.156,0.635 1.156,0.635 0.948,0.635 false 1.448,1.333 1.156,1.729 1.156,1.729 0.938,1.729 false 0.177,0.104 0.427,0.344 0.25,0.24 10 false *a 2.635,0.563 3.063,0.792 0.427,0.229 10 false HT1B 0.698,0.552 1.125,0.781 0.427,0.229 10 false +B 0.719,1.646 1.146,1.875 0.427,0.229 10 false E2 1.49,0.958 1.656,1.135 0.167,0.177 12 true 1 1.813,0.958 1.969,1.125 0.156,0.167 12 true 2 1.813,1.208 1.99,1.375 0.177,0.167 12 true 4 1.49,1.208 1.677,1.406 0.188,0.198 12 true 3
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (HT1B) - 1 (+B) 20°C (68°F) 9 to 14 Ω
2 (HT1B) - 3 (E2) Always 10 kΩ or higher


If the result is not as specified, replace the heated oxygen sensor.