Home › Engine / Hybrid System › 2GR-FE ENGINE CONTROL › HEATED OXYGEN SENSOR › 2013.12–2016.11
RM3160E _51 Engine / Hybrid System _019662 2GR-FE ENGINE CONTROL _0106874 HEATED OXYGEN SENSOR G

2GR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR

a.
A315114C02
1.927,1.208 2.385,0.833 false 1.979,3.198 2.438,2.823 false 1.115,1.958 1.438,1.583 false 1.448,1.188 1.042,0.833 false 1.469,3.198 1.063,2.844 false 1.146,3.938 1.469,3.563 false 0.208,0.698 0.479,0.969 0.271,0.271 12 false *A 0.24,2.719 0.51,3.01 0.271,0.292 12 false *B 0.135,0.125 0.448,0.281 0.313,0.156 10 false *a 2.448,0.729 3.063,0.927 0.615,0.198 10 false HT1B 2.479,2.74 3.094,2.938 0.615,0.198 10 false HT2B 0.833,0.698 1.135,0.927 0.302,0.229 10 false +B 0.844,2.729 1.146,2.958 0.302,0.229 10 false +B 0.885,1.896 1.188,2.125 0.302,0.229 10 false E2 0.917,3.885 1.219,4.115 0.302,0.229 10 false E2 1.49,1.146 1.656,1.344 0.167,0.198 12 true 1 1.781,1.438 1.948,1.635 0.167,0.198 12 true 4 1.479,1.438 1.646,1.615 0.167,0.177 12 true 3 1.771,1.146 1.938,1.344 0.167,0.198 12 true 2
*A for Bank 1
*B for Bank 2
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (HT1B) - 1 (+B)
1 (HT2B) - 2 (+B)
20°C (68°F) 11 to 16 Ω
2 (HT1B) - 3 (E2)
1 (HT2B) - 4 (E2)
Always 10 kΩ or higher


If the result is not as specified, replace the heated oxygen sensor.