Home › Vehicle Exterior › LIGHTING (EXT) › AUTOMATIC LIGHT CONTROL SENSOR
RM3160E _59 Vehicle Exterior _019722 LIGHTING (EXT) _0106954 AUTOMATIC LIGHT CONTROL SENSOR G

LIGHTING (EXT)  AUTOMATIC LIGHT CONTROL SENSOR  INSPECTION  


PROCEDURE

Hide 89120A 1.INSPECT AUTOMATIC LIGHT CONTROL SENSOR

a.
B157083
1.521,0.333 1.896,0.552 0.375,0.219 0.99,1.583 1.438,1.167 false 1.573,1.583 1.604,1.198 false 2.292,1.573 1.979,1.198 false 0.135,0.104 0.344,0.26 0.208,0.156 10 false *a 1.635,0.354 2.063,0.76 0.427,0.406 10 false G4 0.75,1.625 1.156,1.792 0.406,0.167 10 false CLTB 1.438,1.625 1.844,1.792 0.406,0.167 10 false CLTE 2.24,1.635 2.646,1.802 0.406,0.167 10 false CLTS
*a Front view of wire harness connector
(to Automatic Light Control Sensor)


Disconnect the G4 automatic light control sensor connector.


b.

Measure the voltage and resistance according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G4-1 (CLTB) - G4-2 (CLTE) Ignition switch off, dimmer switch off, 2 minutes after all doors closed Below 1 V
Ignition switch ON 11 to 14 V


Standard Resistance:
Tester Connection Condition Specified Condition
G4-2 (CLTE) - Body ground Always Below 1 Ω


If the result is not as specified, there may be a malfunction on the wire harness side.


c.
E259758
1.531,0.271 1.927,0.49 0.396,0.219 1.833,1.177 2.385,0.885 false 1.458,1.167 0.896,0.896 false 0.188,0.135 0.438,0.313 0.25,0.177 10 false *a 1.656,0.302 2.031,0.604 0.375,0.302 10 false G4 0.542,0.771 0.958,0.948 0.417,0.177 10 false CLTS 2.438,0.792 2.833,0.958 0.396,0.167 10 false CLTE
*a Component with harness connected
(Automatic Light Control Sensor)


Reconnect the G4 automatic light control sensor connector.


d.

Connect an oscilloscope to the automatic light control sensor connector.


e.
E276298N01
2.844,1.646 3.219,1.813 0.375,0.167 10 false GND

Check the waveform.

OK:
Tester Connection Tool Setting Condition Specified Condition
G4-4 (CLTS) - G4-2 (CLTE) 2 V/DIV., 10 ms./DIV. Ignition switch ON Correct waveform is as shown


HINT:

The communication waveform changes according to the surrounding brightness.


If the result is not as specified, the automatic light control sensor may be malfunctioning.