Home › Steering › STEERING COLUMN › HEATED STEERING WHEEL SYSTEM
RM3160E _55 Steering _019698 STEERING COLUMN _0107380 HEATED STEERING WHEEL SYSTEM U

STEERING COLUMN  HEATED STEERING WHEEL SYSTEM  TERMINALS OF ECU  


STEERING WHEEL HEATER CONTROL ASSEMBLY


HINT:

Perform the inspection from the harness side with the connectors connected.


C233761
4.626,0.469 4.924,0.647 0.298,0.179 4.719,0.485 4.876,0.667 0.156,0.182 10 A 2.013,0.345 2.311,0.523 0.298,0.179 2.106,0.361 2.263,0.543 0.156,0.182 10 B

a.

Measure the voltage or resistance according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
A-1 (CCU) - Body ground LED output signal Ignition switch ON, Steering heater switch on Below 3 V
A-2 (CCV) - Body ground Steering heater switch input signal Ignition switch ON, Steering heater switch on 11 to 14 V
A-3 (CCX) - Body ground Ground Always Below 1 Ω
A-4 (CCW) - Body ground IG power supply Ignition switch ON 11 to 14 V
B-1 (TH1) - Body ground Thermistor input signal Ignition switch ON, Steering heater switch on at 0 to 40°C (32 to 104°F) 1.5 to 4.5 V*1
B-2 (TH2) - Body ground Thermistor ground Ignition switch ON, Steering heater switch on Below 1 V
B-3 (SH2) - Body ground Heater output signal Ignition switch ON, Steering heater switch on 11 to 14 V*2
B-4 (SH1) - Body ground Heater ground Ignition switch ON, Steering heater switch on Below 1 V

HINT:
·

*1: When ambient temperature is 0 to 40°C (32 to 104°F).

·

*2: The current to the heater turns ON/OFF depending on the temperature of the thermistor. As a result, it may take several minutes before a voltage value is output.