Home › Vehicle Exterior › DOOR / HATCH › POWER BACK DOOR SYSTEM
RM3160E _59 Vehicle Exterior _019719 DOOR / HATCH _0109291 POWER BACK DOOR SYSTEM D

DOOR / HATCH  POWER BACK DOOR SYSTEM  SYSTEM DESCRIPTION  


POWER BACK DOOR SYSTEM DESCRIPTION


a.

The power back door system controls the power back door by automatically opening and closing the power back door with a motor.

i.

The power back door system operates only when the required conditions are satisfied.


ii.

The multiplex network door ECU records the back door positions in the multiplex network door ECU.

If the battery is disconnected, or the multiplex network door ECU fuse, power back door unit assembly set LH, power back door unit assembly set RH, back door lock assembly or multiplex network door ECU is removed and then reinstalled, the back door positions recorded in the multiplex network door ECU will be cleared.

In such a case, initialization of the multiplex network door ECU is necessary. Refer to INITIALIZATION.

Click hereVehicle Exterior>DOOR / HATCH>POWER BACK DOOR SYSTEM>INITIALIZATION


iii.

The multiplex network door ECU receives open/close request signals for the back door. The multiplex network door ECU controls the back door opening/closing operations by sending commands to the back door lock assembly and back door motor.


iv.

The power back door system has various request signals: open/close request signal from the key switch, open/close request signal from the rear door control switch, open request signal from the back door opener switch assembly, open/close request signal from the back door control switch, and off request signal from the door control switch.


v.

The power back door system sounds a buzzer when the power back door starts operating. (for LHD)


vi.

The power back door system sounds a buzzer and flashes the hazard warning lights when the power back door starts operating and intermittently while the power back door operating. (for RHD)


vii.

The power back door system does not reverse the direction that the power back door is operating and stops if any switch is pressed during operation.


viii.

The power back door system stops the operation of the power back door if any switch is pressed during operation.


ix.

A pulse sensor and a power back door sensor assembly are used to prevent foreign objects from being caught in the door while the power back door is closing (jam protection function).



b.

Function of main components:

Component Function
Power back door warning buzzer
·

Sounds for 0.8 seconds when the rear door control switch, back door control switch, back door opener switch assembly or key switch is pressed.

·

Sounds intermittently while the power back door is operating.*

·

Sounds twice for 0.1 seconds to notify that the power back door has stopped operating when the jam protection function is activated.

·

Sounds for 0.2 seconds when the back door opener switch assembly, key switch, back door control switch or rear door control switch is pressed while the power back door is operating.


Hazard warning lights* Flash twice to notify that the power back door will start operating when an open/close request signal is input while the back door is in the closed or fully open position.
Door control switch
·

Disables the power back door system when the switch is off.

·

Enables power back door system operation when the switch is on.


Key switch
·

Pressing the switch causes the back door to open/close.

·

Pressing the switch again causes the operation of the back door to stop.


Rear door control switch Transmits a power back door open/close request signal to the multiplex network door ECU via the main body ECU (multiplex network body ECU).
Back door opener switch assembly Transmits a power back door open request signal to the multiplex network door ECU via the certification ECU (smart key ECU assembly).
Back door control switch Transmits a power back door open/close signal to the multiplex network door ECU.

*: for RHD




POWER BACK DOOR OPERATION TIMING CHART


a.

Opening Operation (using rear door control switch or key switch):

B361514
0.052,0.708 1.354,1.25 1.302,0.542 10 false Rear door control switch or key switch 0.063,1.833 1.271,2.427 1.208,0.594 10 false Power back door warning buzzer 0.073,2.646 1.281,3.24 1.208,0.594 10 false Back door lock motor 0.094,3.792 1.302,4.385 1.208,0.594 10 false Latch switch 0.063,4.635 1.302,5.229 1.24,0.594 10 false Back door courtesy switch 0.052,5.625 1.375,6.188 1.323,0.563 10 false Power back door unit assembly set 0.063,6.563 1.469,6.99 1.406,0.427 10 false Hazard warning light* 0.083,7.031 1.49,7.458 1.406,0.427 10 false State of back door 2.135,7.042 3.542,7.469 1.406,0.427 10 false Fully closed 3.208,7.042 4.615,7.469 1.406,0.427 10 false Door ajar 6,7.052 6.885,7.49 0.885,0.438 10 false Memory stop position 2.396,0.073 4.083,0.271 1.688,0.198 10 false 0.8 seconds 3.813,0.208 6.854,0.49 3.042,0.281 10 false Conditions to start automatic operation are met 3.052,1.042 4.74,1.24 1.688,0.198 10 false 0.8 seconds 1.823,2 2.813,2.375 0.99,0.375 10 false Returns to original position 1.865,2.833 3.094,3.313 1.229,0.479 10 false Release output 2.031,5.219 2.958,5.563 0.927,0.344 10 false Open output 4.417,5.438 5.302,5.927 0.885,0.49 10 false Speed control range 1.448,0.948 1.906,1.146 0.458,0.198 10 false OFF 1.521,0.625 1.979,0.823 0.458,0.198 10 false ON 1.469,1.885 1.927,2.083 0.458,0.198 10 false OFF 1.469,3.792 1.927,3.99 0.458,0.198 10 false OFF 1.469,4.76 1.927,4.958 0.458,0.198 10 false OFF 1.458,5.698 1.917,5.896 0.458,0.198 10 false OFF 1.458,6.667 1.917,6.865 0.458,0.198 10 false OFF 1.521,1.542 1.979,1.74 0.458,0.198 10 false ON 1.531,3.458 1.99,3.656 0.458,0.198 10 false ON 1.531,4.448 1.99,4.646 0.458,0.198 10 false ON 1.521,6.354 1.979,6.552 0.458,0.198 10 false ON 0.177,7.438 0.885,7.625 0.708,0.188 10 false *: for RHD


b.

Opening Operation (using back door opener switch assembly):

B361510
0.052,0.552 1.177,0.99 1.125,0.438 10 false Back door opener switch assembly 0.052,1.531 1.115,1.969 1.063,0.438 10 false Power back door warning buzzer 0.063,2.396 1.031,2.865 0.969,0.469 10 false Back door lock motor 0.073,3.677 1.042,4.146 0.969,0.469 10 false Latch switch 0.042,4.406 1.271,4.885 1.229,0.479 10 false Back door courtesy switch 0.042,5.292 1.385,5.75 1.344,0.458 10 false Power back door unit assembly set 0.042,6.333 1.385,6.677 1.344,0.344 10 false Hazard warning light* 0.094,7.01 1.438,7.354 1.344,0.344 10 false State of back door 2.063,7.031 3.406,7.375 1.344,0.344 10 false Fully closed 3.313,7.01 4.656,7.354 1.344,0.344 10 false Door ajar 6.083,7.01 6.979,7.396 0.896,0.385 10 false Memory stop position 1.51,0.51 1.844,0.771 0.333,0.26 10 false ON 1.448,0.833 1.781,1.094 0.333,0.26 10 false OFF 1.521,1.49 1.854,1.75 0.333,0.26 10 false ON 1.458,1.781 1.792,2.042 0.333,0.26 10 false OFF 1.531,3.396 1.865,3.656 0.333,0.26 10 false ON 1.458,3.698 1.792,3.958 0.333,0.26 10 false OFF 1.469,4.656 1.802,4.917 0.333,0.26 10 false OFF 1.531,4.385 1.865,4.646 0.333,0.26 10 false ON 1.458,5.604 1.792,5.865 0.333,0.26 10 false OFF 1.458,6.552 1.792,6.813 0.333,0.26 10 false OFF 1.521,6.281 1.854,6.542 0.333,0.26 10 false ON 3.875,0.438 6.906,0.688 3.031,0.25 10 false Conditions to start automatic operation are met 3.135,0.927 4.01,1.167 0.875,0.24 10 false 0.8 seconds 1.823,1.896 2.813,2.375 0.99,0.479 10 false Returns to original position 3.875,1.99 6.198,2.313 2.323,0.323 10 false Operation standby time 1.969,2.74 4.292,3.063 2.323,0.323 10 false Release output 2.135,5.125 4.458,5.448 2.323,0.323 10 false Open output 4.771,5.354 5.698,5.854 0.927,0.5 10 false Speed control range 0.125,7.417 1.656,7.615 1.531,0.198 10 false *: for RHD


c.

Opening Operation (using back door control switch):

B361504
3.833,0.458 6.729,0.708 2.896,0.25 10 false Conditions to start automatic operation are met 3.083,2.552 3.875,2.74 0.792,0.188 10 false 0.8 seconds 1.813,2.063 2.604,2.25 0.792,0.188 10 false 0.8 seconds 4.281,3.51 5.167,4.021 0.885,0.51 10 false Speed control range 2.01,3.271 2.885,3.531 0.875,0.26 10 false Open output 0.094,4.594 1.448,4.875 1.354,0.281 10 false Hazard warning light* 1.5,4.448 1.802,4.698 0.302,0.25 10 false ON 1.5,1.969 1.802,2.219 0.302,0.25 10 false ON 1.5,0.677 1.802,0.927 0.302,0.25 10 false ON 1.438,0.99 1.74,1.24 0.302,0.25 10 false OFF 1.438,2.26 1.74,2.51 0.302,0.25 10 false OFF 1.438,3.76 1.74,4.01 0.302,0.25 10 false OFF 1.448,4.75 1.75,5 0.302,0.25 10 false OFF 0.073,0.688 1.01,1.115 0.938,0.427 10 false Back door control switch 0.073,2 1.208,2.427 1.135,0.427 10 false Power back door warning buzzer 0.063,3.583 1.375,4 1.313,0.417 10 false Power back door unit assembly set 5.76,5.219 7.115,5.479 1.354,0.26 10 false Memory stop position 0.188,5.188 1.406,5.417 1.219,0.229 10 false State of back door 2.563,5.198 3.385,5.552 0.823,0.354 10 false Manual stop position 0.188,5.49 0.906,5.698 0.719,0.208 10 false *: for RHD


d.

Closing Operation (using rear door control switch or key switch):

B361511
0.042,0.844 1.375,1.479 1.333,0.635 10 false Rear door control switch or key switch 0.042,1.833 1.104,2.292 1.063,0.458 10 false Power back door warning buzzer 0.052,2.729 1.021,3.188 0.969,0.458 10 false Back door lock motor 0.052,3.583 1.021,4.042 0.969,0.458 10 false Latch switch 0.052,4.531 1.271,5.021 1.219,0.49 10 false Back door courtesy switch 0.042,5.583 1.365,6.073 1.323,0.49 10 false Power back door unit assembly set 0.063,6.74 1.448,7.083 1.385,0.344 10 false Hazard warning light* 0.083,7.229 1.469,7.573 1.385,0.344 10 false State of back door 2.448,7.26 3.833,7.563 1.385,0.302 10 false Stop position 5.469,7.26 6.854,7.563 1.385,0.302 10 false Door ajar 6.313,7.281 7.156,7.573 0.844,0.292 10 false Fully closed 2.208,0.094 3.167,0.333 0.958,0.24 10 false 0.8 seconds 2.906,1.167 3.865,1.406 0.958,0.24 10 false 0.8 seconds 3.667,0.354 6.677,0.656 3.01,0.302 10 false Conditions to start automatic operation are met 5.938,2.26 7.104,2.573 1.167,0.313 10 false 1 second pause 3.646,2.479 4.813,2.792 1.167,0.313 10 false Pull-in output 3.292,2.979 4.458,3.406 1.167,0.427 10 false Returns to original position 2.969,4.823 4.802,5.094 1.833,0.271 10 false Closer delay time 1 second 1.896,5.365 3.729,5.635 1.833,0.271 10 false Close output 3.531,5.594 4.438,6.042 0.906,0.448 10 false Speed control range 1.531,0.792 1.844,0.99 0.313,0.198 10 false ON 1.469,1.083 1.917,1.323 0.448,0.24 10 false OFF 1.542,1.708 1.854,1.906 0.313,0.198 10 false ON 1.479,2.021 1.927,2.26 0.448,0.24 10 false OFF 1.552,3.615 1.865,3.813 0.313,0.198 10 false ON 1.479,3.885 1.927,4.125 0.448,0.24 10 false OFF 1.5,4.823 1.948,5.063 0.448,0.24 10 false OFF 1.563,4.563 1.875,4.76 0.313,0.198 10 false ON 1.5,5.833 1.948,6.073 0.448,0.24 10 false OFF 1.49,6.802 1.938,7.042 0.448,0.24 10 false OFF 1.563,6.5 1.875,6.698 0.313,0.198 10 false ON 0.115,7.521 0.813,7.719 0.698,0.198 10 false *: for RHD


e.

Closing Operation (using back door control switch):

B361512
0.052,0.938 1.167,1.406 1.115,0.469 10 false Back door control switch 0.031,1.917 1.104,2.365 1.073,0.448 10 false Power back door warning buzzer 0.042,2.688 1.115,3.135 1.073,0.448 10 false Back door lock motor 0.052,3.563 1.125,4.01 1.073,0.448 10 false Latch switch 0.052,4.51 1.281,4.958 1.229,0.448 10 false Back door courtesy switch 0.031,5.708 1.365,6.156 1.333,0.448 10 false Power back door unit assembly set 0.052,6.719 1.385,7.167 1.333,0.448 10 false Hazard warning light* 0.073,7.229 1.406,7.677 1.333,0.448 10 false State of back door 2.563,7.26 3.896,7.708 1.333,0.448 10 false Stop position 5.667,7.26 7,7.708 1.333,0.448 10 false Fully closed 2.5,0.167 3.385,0.448 0.885,0.281 10 false 0.8 seconds 3.5,0.698 6.542,0.969 3.042,0.271 10 false Conditions to start automatic operation are met 2.719,1.208 3.604,1.49 0.885,0.281 10 false 0.8 seconds 5.938,2.25 7.104,2.563 1.167,0.313 10 false 1 second pause 3.635,2.49 4.802,2.802 1.167,0.313 10 false Pull-in output 3.344,2.979 4.51,3.49 1.167,0.51 10 false Returns to original position 3.156,4.885 4.875,5.219 1.719,0.333 10 false Closer delay time 1 second 1.917,5.365 3.635,5.698 1.719,0.333 10 false Close output 3.656,5.594 4.583,6.115 0.927,0.521 10 false Speed control range 1.479,1.083 1.938,1.281 0.458,0.198 10 false OFF 1.563,0.76 2.021,0.958 0.458,0.198 10 false ON 1.479,2.031 1.938,2.229 0.458,0.198 10 false OFF 1.552,1.708 2.01,1.906 0.458,0.198 10 false ON 1.49,3.917 1.948,4.115 0.458,0.198 10 false OFF 1.552,3.625 2.01,3.823 0.458,0.198 10 false ON 1.51,4.854 1.969,5.052 0.458,0.198 10 false OFF 1.573,4.563 2.031,4.76 0.458,0.198 10 false ON 1.5,5.844 1.958,6.042 0.458,0.198 10 false OFF 1.521,6.802 1.979,7 0.458,0.198 10 false OFF 1.583,6.49 2.042,6.688 0.458,0.198 10 false ON 0.094,7.51 0.771,7.719 0.677,0.208 10 false *: for RHD